Search results for " Instrumentation."
showing 10 items of 712 documents
Simultaneous Noise and Impedance Fitting to Transition-Edge Sensor Data using Differential Evolution
2019
We discuss a robust method to simultaneously fit a complex model both to the complex impedance and the noise data for transition-edge sensors (TES). It is based on a differential evolution (DE) algorithm, providing accurate and repeatable results with only a small increase in computational cost compared to the standard least squares (LS) fitting method. Test fits are made using both DE and LS methods, and the results compared with previously determined best fits, with varying initial value deviations and limit ranges for the parameters. The robustness of DE is demonstrated with successful fits even when parameter limits up to a factor of 5 from the known values were used. It is shown that t…
Method for finding the critical temperature of the island in a SET structure
2008
We present a method to measure the critical temperature of the island of a superconducting single electron transistor. The method is based on a sharp change in the slope of the zero-bias conductance as a function of temperature. We have used this method to determine the superconducting phase transition temperature of the Nb island of an superconducting single electron transistor with Al leads. We obtain $T_\mathrm{c}^\mathrm{Nb}$ as high as 8.5 K and gap energies up to $\Delta_\mathrm{Nb}\simeq 1.45$ meV. By looking at the zero bias conductance as a function of magnetic field instead of temperature, also the critical field of the island can be determined. Using the orthodox theory, we have …
Highly sensitive superconducting circuits at ∼700 kHz with tunable quality factors for image-current detection of single trapped antiprotons
2016
We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550$\sim$800$\,$kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500$\,$000, which corresponds to a factor of 10 improvement compared to our previously used solenoidal designs. Connected to ultra-low noise amplifiers and the trap system, signal-to-noise-ratios of 30$\,$dB at quality factors of > 20$\,$000 are achieved. In addition, we have developed a superconducting switch which allows continuous tu…
Commissioning of the ATLAS Muon Spectrometer with cosmic rays
2010
The ATLAS detector at the Large Hadron Collider has collected several hundred million cosmic ray events during 2008 and 2009. These data were used to commission the Muon Spectrometer and to study the performance of the trigger and tracking chambers, their alignment, the detector control system, the data acquisition and the analysis programs. We present the performance in the relevant parameters that determine the quality of the muon measurement. We discuss the single element efficiency, resolution and noise rates, the calibration method of the detector response and of the alignment system, the track reconstruction efficiency and the momentum measurement. The results show that the detector i…
Readiness of the ATLAS Tile Calorimeter for LHC collisions
2010
67 páginas.-- El PDF es la versión pre-print (arXiv:1007.5423v2).-- The ATLAS Collaboration.-- et al.
Direct assessment of the sensitivity drift of SQM sensors installed outdoors
2021
Long-term monitoring of the evolution of the artificial night sky brightness is a key tool for developing science-informed public policies and assessing the efficacy of light pollution mitigation measures. Detecting the underlying artificial brightness trend is a challenging task, since the typical night sky brightness signal shows a large variability with characteristic time scales ranging from seconds to years. In order to effectively isolate the weak signature of the effect of interest, determining the potential long term drifts of the radiance sensing systems is crucial. If these drifts can be adequately characterized, the raw measurements could be easily corrected for them and transfor…
Volume III. DUNE far detector technical coordination
2020
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay-these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the st…
Volume IV The DUNE far detector single-phase technology
2020
This document was prepared by the DUNE collaboration using the resources of the Fermi National Accelerator Laboratory (Fermilab), a U.S. Department of Energy, Office of Science, HEP User Facility. Fermilab is managed by Fermi Research Alliance, LLC (FRA), acting under Contract No. DE-AC02-07CH11359. The DUNE collaboration also acknowledges the international, national, and regional funding agencies supporting the institutions who have contributed to completing this Technical Design Report.
Day-to-Day Variability and Year-to-Year Reproducibility of Accelerometer-Measured Free-Living Sit-to-Stand Transitions Volume and Intensity among Com…
2021
(1) Background: The purpose of this study was to evaluate the day-to-day variability and year-to-year reproducibility of an accelerometer-based algorithm for sit-to-stand (STS) transitions in a free-living environment among community-dwelling older adults. (2) Methods: Free-living thigh-worn accelerometry was recorded for three to seven days in 86 (women n = 55) community-dwelling older adults, on two occasions separated by one year, to evaluate the long-term consistency of free-living behavior. (3) Results: Year-to-year intraclass correlation coefficients (ICC) for the number of STS transitions were 0.79 (95% confidence interval, 0.70-0.86, p < 0.001), for mean angular velocity-0.81 (95% c…
Open data from the first and second observing runs of advanced LIGO and advanced Virgo
2021
Abbot, Rich, et al. (Virgo and MAGIC Collaboration)