Endoscopy in aneurysm surgery.
2011
BACKGROUND: Surgical clipping with complete occlusion of the aneurysm and preservation of parent, branching, and perforating vessels remains the most definitive treatment for intracranial aneurysms. OBJECTIVE: To evaluate the benefit of endoscopic application during microsurgical procedures in a retrospective study. METHODS: One hundred eighty aneurysms were microsurgically treated in 124 operations. Three different applications of endoscopic visualization were used, depending on the respective requirements: inspection before clipping, clipping under endoscopic view, and postclipping evaluation. RESULTS: Of 1380 aneurysms, 292 procedures were done with application of the endoscope. Of these…
Screening for generalized anxiety disorder in Spanish primary care centers with the GAD-7.
2017
The aim of the study was to determine the criterion validity of a computerized version of the General Anxiety Disorder-7 (GAD-7) questionnaire to detect general anxiety disorder in Spanish primary care centers. A total of 178 patients completed the GAD-7 and were administered the Composite International Diagnostic Interview (CIDI) for DSM-IV Axis I Disorders, which was used as a reference standard. Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios were calculated. A cut-off of 10 yielded a sensitivity of .87, a specificity of .78, a positive predictive value of .93, a negative predictive value of .64, a positive likelihood ratio o…
Water Jet Dissection in Neurosurgery: An Update After 208 Procedures With Special Reference to Surgical Technique and Complications
2010
Background Water jet dissection represents a promising technique for precise brain tissue dissection with preservation of blood vessels. In the past, the water jet dissector has been used for various pathologies. A detailed report of the surgical technique is lacking. Objective The authors present their results after 208 procedures with a special focus on surgical technique, intraoperative suitability, advantages, and disadvantages. Methods Between March 1997 and April 2009, 208 patients with various intracranial neurosurgical pathologies were operated on with the water jet dissector. Handling of the device and its usefulness and extent of application were assessed. The pressures encountere…
A gelatin-thrombin matrix topical hemostatic agent (Floseal) in combination with harmonic scalpel is effective in patients undergoing total thyroidec…
2016
BACKGROUND: Hemostasis during thyroidectomy is essential; however, the safest, most efficient, and most cost-effective way to achieve this is unclear. This randomized, multicenter, single-blind, prospective study evaluated the efficacy and safety of using different hemostatic approaches in patients undergoing total thyroidectomy. METHODS: Patients aged ≥18 to 70 years were randomized to Floseal + a harmonic scalpel (HS), Floseal alone, HS alone, or standard total thyroidectomy. Primary endpoint was 24-hour drain output. Secondary endpoints included surgery duration and complications. RESULTS: Two hundred and six patients were randomized to Floseal + HS (n = 52), Floseal alone (n = 54), HS a…
Laparoscopic Management of External Iliac Artery Injury Using Yasargil Clamps and Intracorporeal Suture
2011
Presented is a case report of laparoscopic repair of an external iliac artery injury using titanium Yasargil clamps and intracorporeal suture during lymphadenectomy. Yasargil clamps were introduced and placed, 1 distal and 1 proximal to the lesion. The vascular injury site was identified and repaired using intracorporeal sutures. Laparoscopic staging was completed successfully. No sign of thrombosis or vascular occlusion was detected. The patient was discharged on postoperative day 4 to receive adjuvant therapy. Laparotomy is the accepted way of managing major vascular injuries during laparoscopy. However, in controlled circumstances, with availability of Yasargil clamps and a surgeon exper…
Prospective randomized comparison of conventional instruments and the Harmonic Focus(®) device in breast-conserving therapy for primary breast cancer.
2011
Abstract Background In recent years, surgeons have utilized Harmonic instruments to perform breast cancer resection. Retrospective and prospective studies have demonstrated that the use of this surgical device for mastectomy and axillary dissection can reduce perioperative blood loss, seroma formation, and duration and total amount of drainage. No study has analyzed the feasibility of Harmonic instruments in breast-conserving surgery. We conducted a prospective, randomized clinical trial comparing Harmonic instrument and conventional surgery in the performance of breast-conserving surgery and axillary procedures to determine differences in surgical procedures, postoperative outcome, and com…
Aspen Plus process-simulation model: Producing biogas from VOC emissions in an anaerobic bioscrubber
2018
A process-simulation model for a novel process consisted of an anaerobic bioscrubber was developed in Aspen Plus®. A novel approach was performed to implement the anaerobic reactor in the simulation, enabling it to be connected to the scrubber. The model was calibrated and validated using data from an industrial prototype that converted air emissions polluted with volatile organic compounds with an average daily concentration of 1129 mgC Nm−3 into bioenergy for more than one year. The scrubber, which showed a removal efficiency within 83-93%, was successfully predicted with an average absolute relative error of 5.2 ± 0.08% using an average height-to-theoretical-plate value of 1.05 ± 0.08 m …
A Refractive Index Sensor Based on the Resonant Coupling to Cladding Modes in a Fiber Loop
2013
We report an easy-to-build, compact, and low-cost optical fiber refractive index sensor. It consists of a single fiber loop whose transmission spectra exhibit a series of notches produced by the resonant coupling between the fundamental mode and the cladding modes in a uniformly bent fiber. The wavelength of the notches, distributed in a wavelength span from 1,400 to 1,700 nm, can be tuned by adjusting the diameter of the fiber loop and are sensitive to refractive index changes of the external medium. Sensitivities of 170 and 800 nm per refractive index unit for water solutions and for the refractive index interval 1.40-1.442, respectively, are demonstrated. We estimate a long range resolut…
In vitro evaluation of the ability of three apex locators to determine the working length during retreatment.
2005
The purpose of this in vitro study was to evaluate the accuracy of three apex locators in determining the working length during the retreatment process. Twenty extracted single-rooted human teeth with mature apices were used in this study. The root canal length of each tooth was measured placing a #15 file until the tip was visible at the apical foramen. The direct visual measurement was reduced by 0.5 mm and recorded. The root canals were instrumented and filled to the direct visual measurement using lateral compaction technique. After 7 days the teeth were retreated using three apex locators: ProPex, NovApex, and Root ZX, for determining the retreatment working length. Afterward, comparis…
How Many Secret Details Could a Systematic Multi-Analytical Study Reveal About the Mysterious Fresco Trionfo della Morte?
2019
The &ldquo