Search results for " Intraocular"

showing 10 items of 215 documents

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Descemet Membrane Endothelial Keratoplasty for Corneal Decompensation Secondary to Phakic Intraocular Lenses

2019

Purpose. To describe the surgical technique and clinical outcomes of bilensectomy (pIOL explant and phacoemulsification), followed by DMEK performed for bullous keratopathy secondary to pIOL.Methods. Seven eyes of seven patients, who developed corneal decompensation after pIOL implantation, underwent bilensectomy followed by DMEK in a two-step procedure. Main outcome measures included uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), refraction, endothelial cell density (ECD) at 1, 3, 6, and 12 months, and intraoperative and postoperative complications.Results. DMEK was performed at a mean time of 9.83 ± 8.23 months after bilensectomy. BCVA (log MAR) improved in all …

medicine.medical_specialtyVisual acuityDescemet membraneCorneal Decompensationgenetic structuresArticle Subjectbusiness.industrymedicine.medical_treatmentUncorrected visual acuityPhacoemulsificationPhakic intraocular lenseye diseasesOphthalmologylcsh:Ophthalmologylcsh:RE1-994OphthalmologyBullous keratopathymedicinePrimary graft failuremedicine.symptombusinessResearch ArticleJournal of Ophthalmology
researchProduct

ATD perimetry in glaucoma and ocular hypertensive patients. A preliminar study

2007

Purpose: The new ATD perimetry assesses contrast sentivity thresholds for the three afferent sensory pathways of the visual system. Our aim is to compare contrast sensitivity to stimuli with different spatio-temporal frequencies in glaucomatous (G) and ocular hypertensive (OHT) subjects. Methods: Twenty three G and OHT subjects were selected from the ophthalmic clinic, all subjects signed an informed consent. Inclusion criteria were diagnosis of G or OHT, normal Farnsworth-Munsell color test, ametropia less than 6 D, visual acuity over 20/30, absence of previous ocular surgery and experience in perimetry. Twenty locations and the fovea were evaluated in a 60o x 40o fovea-centered field. Eig…

medicine.medical_specialtyVisual acuitybusiness.industryOcular surgeryColor testGlaucomamedicine.diseaseOphthalmologyAfferentOphthalmologymedicineStatistical analysisAnalysis of variancemedicine.symptomHigh intraocular pressurebusinessActa Ophthalmologica Scandinavica
researchProduct

Reading ability with 3 multifocal intraocular lens models.

2006

Purpose To prospectively evaluate reading performance with of 3 types of multifocal intraocular lenses (IOLs) under different lighting conditions based on reading acuity and reading speed tests. Setting Augenklinik, Bad Hersfeld, Germany. Methods This randomized study comprised 60 cataract patients (120 eyes) randomly assigned to receive an SA40N IOL (AMO) (Group 1, 20 patients), Tecnis ZM001 IOL (AMO) (Group 2, 20 patients), or AcrySof ReSTOR SA60D3 IOL (Alcon) (Group 3, 20 patients). Pupil size and reading ability at near (visual acuity, reading speed) without correction, with best distance correction, and with best near correction were assessed 6 weeks postoperatively under low-light con…

medicine.medical_specialtyVisual acuitygenetic structuresLightPseudophakiamedicine.medical_treatmentmedia_common.quotation_subjectEye diseaseVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularOphthalmologyReading (process)medicineHumansProspective Studiesmedia_commonLenses IntraocularPhacoemulsificationbusiness.industrySignificant differencePupil sizePupilMultifocal intraocular lensMiddle Agedmedicine.diseaseDistance correctioneye diseasesSensory SystemsOphthalmologyReadingOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Postoperative Lens Position Preoperatively Determined by Scheimpflug Photography

1999

The position of the artificial lens has an important influence on refractive power calculation. We compared the position of the crystalline lens with that of the artificial lens after cataract surgery by means of Scheimpflug photography. A difference in position of approximately 0.8 mm in the anterior direction could be determined.

medicine.medical_specialtygenetic structuresComputer Science::Neural and Evolutionary ComputationScheimpflug principlePhysics::OpticsAfter cataractOptical powerCataract ExtractionAstrophysics::Cosmology and Extragalactic Astrophysicslaw.inventionCataract extractionCellular and Molecular NeuroscienceLens Implantation IntraocularPosition (vector)lawProsthesis FittingOphthalmologyLens CrystallinePreoperative Caremental disordersPhotographymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryPhotographyGeneral Medicineeye diseasesSensory SystemsLens (optics)OphthalmologyOptometrysense organsbusinesspsychological phenomena and processesOphthalmic Research
researchProduct

Lens implant selection with absence of capsular support.

2001

If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…

medicine.medical_specialtygenetic structuresLens Capsule CrystallineGlaucomaProsthesis DesignAphakiaLens Implantation IntraocularAnterior Eye SegmentCorneaOphthalmologyProsthesis FittingMedicineHumansLenses Intraocularbusiness.industrySuture TechniquesGeneral Medicinemedicine.diseaseeye diseasesAnterior Eye SegmentContact lensOphthalmologymedicine.anatomical_structureAniridiasense organsImplantbusinessShallow anterior chamberCurrent opinion in ophthalmology
researchProduct

Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…

2012

Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…

medicine.medical_specialtygenetic structuresSpectral domainPositional analysislcsh:OphthalmologyOptical coherence tomographyIn vivoOphthalmologymedicinelcsh:QC350-467Optical coherence tomographymedicine.diagnostic_testbusiness.industrySpectral-domaineye diseasesPosterior chamber phakic intraocular lensTomografía de coherencia ópticaLentes refractivas fáquicaslcsh:RE1-994Anatomical relationshipOriginal Articlesense organsDominio espectralPhakic Refractive Lens (PRL)businesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

2017

Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…

medicine.medical_specialtygenetic structuresSpherical equivalentMean differencelaw.invention03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical ResearchlawOphthalmologymedicineDioptreKeratometerbusiness.industry1733autorefractionvector analysisRepeatabilityMultifocal intraocular lensRefractioneye diseasesOphthalmologylcsh:RE1-994Autorefractor030221 ophthalmology & optometrymultifocal intraocular lensessense organsbusinessagreement030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

The "sandwich technique" for iris-fixated phakic intraocular lens implantation.

2006

ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]

medicine.medical_specialtygenetic structuresbusiness.industryAnterior Chambermedicine.medical_treatmentSuture TechniquesIrisIntraocular lensAnterior surfacePhakic intraocular lensRefractive Surgical ProceduresOphthalmologyLens Implantation IntraocularOphthalmologymedicineHumansSurgerybusinessSandwich techniqueJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

2011

Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmu…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentToric phakic intraocular lensNystagmusPhakic intraocular lenseye diseasesMyopic astigmatismOphthalmologyLeft eyeNystagmuslcsh:OphthalmologyOphthalmologic examinationlcsh:RE1-994OphthalmologyRefractive surgeryMedicineIn patientPublished: August 2011sense organsmedicine.symptomRefractive surgerybusinessCongenital nystagmusCase Reports in Ophthalmology
researchProduct