Search results for " Lamin"
showing 10 items of 148 documents
A comparison among different kinds of stator lamination in tubular linear machines
2016
In this paper the authors perform a comparison among three different stator structures for a Tubular Permanent Magnet Linear Machine. Each structure is characterized by its own lamination which is expected to contribute to the overall performance of the machine. A detailed analysis of the main figures of merit of the three configurations has been carried out in order to identify the configuration with the best characteristics. Significant data such as flux distribution, rated voltage and current, force on the moved and power losses have been compared. The results show that the choice of a mixed stator lamination allows to improve the performance of these machines.
The pia mater at the site of the entry of blood vessels into the central nervous system
1982
The entry of blood vessels into the central nervous system (CNS) has been studied at the surface of the brain stem and the spinal cord of two cats and two rabbits. The study was carried out by scanning electron microscopy (SEM). The results obtained by SEM concerning the layers of the pia mater corresponded to those obtained by other authors who used transmission electron microscopy. Between the basal lamina of the superficial glial membrane of the CNS and the cells lining the subarachnoid space, a pial connective tissue space could be clearly recognized. The blood vessles crossing the subarachnoid space were also covered by leptomeningeal lining cells. At the site of entry of these blood v…
Concrete columns confined with fibre reinforced cementitious mortars: Experimentation and modelling
2014
Abstract The structural behaviour of concrete columns strengthened with a system made up of fibre nets embedded in an inorganic stabilized cementitious matrix under an uniaxial load was investigated. Medium size specimens with circular and square cross-section were cast and subjected to monotonic uniaxial compression, to investigate the efficiency of a p-Phenylene BenzobisOxazole (PBO) Fibre Reinforced Cementitious Mortar (FRCM) system in increasing both strength and ductility. The experimental results show that the confinement system adopted produced a noticeable increment in strength and ductility, though the low mechanical ratios of fibre considered were not always able to ensure hardeni…
Evaluation of interlaminar delaminations in titanium-graphite fibre metal laminates by infrared NDT techniques
2018
Abstract Fibre Metal Laminates (FMLs) describe a number of aerospace-grade layered structural materials where thin metal alloy foils are interleaved with Fibre Reinforced Polymer (FRP) plies. Such material hybridisation at the layer meso-scale poses a challenge for non-destructive testing (NDT). On the other hand, the need for NDT inspection of FMLs arises due to the potential development of interlayers disbonds, both during fabrication or in-service. This work describes the successful implementation of two Infrared-NDT approaches to evaluate a defected FML panel made of Titanium/Graphite (Ti-Gr). One technique is based on the modulation of the deployed heat from a low-cost halogen lamp, to…
An analysis of interface delamination mechanisms in orthotropic and hybrid fiber-metal composite laminates
2007
Abstract The onset and propagation of interlaminar defects is one of the main damage mechanisms in composite materials. This is even more the case when considering layered materials comprising metallic laminae (typically Aluminium) and FRP laminae. Propagation of delamination mainly depends on the initial crack extension and its loading mode. This work presents some results of a combined analytical–numerical–experimental study on the onset and propagation mechanisms regarding interlaminar defects. Two cases have been analysed in particular, the first consisting of a glass-fibre reinforced epoxy resin laminate, and the second consisting of a hybrid laminate where a lamina of aluminium is lay…
Dependence of fracture toughness of composite laminates on interface ply orientations and delamination growth direction
2004
A critical review has been performed of the published experimental research concerning delamination onset and growth in composite laminate interfaces of different lay-ups under single-mode loadings. It was found that, depending on the loading mode and interface lay-up, the traditional fracture toughness characterization by unidirectionally reinforced composite tests can lead to marked under- or overestimation of material resistance to crack growth. Empirical models of fracture toughness as a function of delamination front orientation with respect to reinforcement directions of the adjacent laminae have been validated and their applicability range established.
Delamination study of through-thickness reinforced composite laminates via two-phase interface model
2007
A technique to enhance the strength of the composite laminates in the thickness direction consists in inserting through-thickness reinforcement, by which the potential delamination crack faces are bridged in order to increase the interlaminar fracture strength. In this paper, the composite delamination is analyzed in the context of non-linear fracture mechanics making use of the interface concept. The presence of the reinforcement fibres provides an anisotropic elastic and post-elastic mechanical response, which herein is described by an original two-phase interface model. The two phases, namely the adhesive joint (or matrix of the composite) and the reinforcement, are characterized by thei…
Finite elements for nonlinear free vibrations analysis of smart laminates subjected to in-plane loadings
2015
Advanced composites, able to provide multi-functional capabilities besides the traditional structural functions, has been gaining attention in many technological fields. This inherent coupling of different physical fields can be exploited in transducer applications, structural health monitoring, vibration control, energy harvesting and other applications. Magneto-electro-elastic (MEE) composite materials are attracting increasing consideration as they couple mechanical, electrical and magnetic fields and this makes them particularly suitable for smart applications. Generally, single-phase materials exhibit either piezoelectric or piezomagnetic behavior and no direct magneto-electric couplin…
Flexural behavior of laminated glass beams with T cross-sections
2014
Heat transfer and flow resistance for stacked wire gauzes: Experiments and modelling
2012
Abstract The study deals with the flow resistance and heat transport properties of woven and knitted wire gauzes stacked in a tubular apparatus. The experimental programme included flow resistance and heat transfer experiments performed for air flow ( Re = 2–300) using three woven gauzes and one knitted gauze. During the heat transfer experiments, the gauzes were heated by electric current flowing directly through them. The models describing the flow resistance and the heat transfer were put forward. Both the models base on the concept of the laminar flow developing in a short capillary channel (i.e. the gauze mesh). The model describing the flow resistance does not contain the experimenta…