Search results for " Leakage"

showing 10 items of 86 documents

An international multicentre prospective audit of elective rectal cancer surgery; operative approach versus outcome, including transanal total mesore…

2018

Introduction: Transanal total mesorectal excision (TaTME) has rapidly emerged as a novel approach for rectal cancer surgery. Safety profiles are still emerging and more comparative data is urgently needed. This study aimed to compare indications and short-term outcomes of TaTME, open, laparoscopic, and robotic TME internationally. Methods: A pre-planned analysis of the European Society of Coloproctology (ESCP) 2017 audit was performed. Patients undergoing elective total mesorectal excision (TME) for malignancy between 1 January 2017 and 15 March 2017 by any operative approach were included. The primary outcome measure was anastomotic leak. Results: Of 2579 included patients, 76.2% (1966/257…

MaleLaparoscopic surgerymedicine.medical_specialtyColorectal cancermedicine.medical_treatmentOperative TimeAnastomosisMalignancyrectal cancer ; laparoscopic surgery ; TME ; transanal TME ; TaTME ; robotic surgery ; randomized clinical-trial ; short-term outcomes ; laparoscopic-assisted resection ; pathological outcomes ; anastomotic leakage ; initial-experience ; riskNO03 medical and health sciencesPostoperative Complications0302 clinical medicineRobotic Surgical Proceduresrobotic surgerytransanal TMEHumansMedicineRobotic surgeryProspective Studieslaparoscopic surgery; Rectal cancer; robotic surgery; TaTME; TME; transanal TME; GastroenterologyRectal cancerAgedTransanal Endoscopic Surgeryta3126Medical AuditUnivariate analysisProctectomyRectal Neoplasmsbusiness.industryRectumGastroenterologyTMEMargins of ExcisionMiddle Agedmedicine.diseaseTotal mesorectal excisionTaTMElaparoscopic surgerySurgeryTreatment OutcomeElective Surgical Procedures030220 oncology & carcinogenesisRectal cancer surgeryFemaleLaparoscopy030211 gastroenterology & hepatologybusiness
researchProduct

A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates

2007

<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…

Malemedicine.medical_specialtySiliconesPostoperative ComplicationsClivusmedicineAnimalsMinimally Invasive Surgical ProceduresBase (exponentiation)Cerebrospinal FluidSkull BaseCerebrospinal Fluid Leakagebusiness.industryForeign-Body ReactionSilicone plugEndoscopyProstheses and ImplantsLong term resultsPlastic Surgery ProceduresAnti-Bacterial AgentsSurgerySkullmedicine.anatomical_structureModels AnimalSkull base surgeryInvasive surgeryPapio hamadryasSurgerybusinessEuropean Surgical Research
researchProduct

Pringle maneuver increases the risk of anastomotic leakage after colonic resection in rats.

2018

Abstract Background Many centers use the Pringle's maneuver during liver resections. Since this maneuver might impair healing of bowel anastomoses, we evaluated its influence on the healing of colonic anastomosis in rats. Methods Male Wistar rats underwent median laparotomy and sigmoid resection with end-to-end anastomosis under inhalation anesthesia. Thereafter, rats received a 25 minutes Pringle's maneuver (PM, group 1) or were kept under anesthesia for the same period of time (group 2). The anastomotic bursting pressure (BP) was measured on postoperative days (POD) 3, 6 and 9. Hematoxylin and Eosin (H&E) staining was used for histopathological evaluation of the anastomosis. The Mann-Whit…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentH&E stainColonic anastomosisAnastomotic Leak030230 surgeryAnastomosis03 medical and health sciences0302 clinical medicineWeight lossColon SigmoidRisk FactorsLaparotomyWeight LossMedicineAnimalsRats WistarColectomyWound HealingHepatologybusiness.industryColonic resectionGastroenterologyColorectal surgerySurgeryAnastomotic leakage030220 oncology & carcinogenesismedicine.symptombusinessHPB : the official journal of the International Hepato Pancreato Biliary Association
researchProduct

Effect of cavity preparation instruments (oscillating or rotating) on the composite-dentin interface in primary teeth.

2003

Abstract Objectives: To evaluate the effect of preparation of instruments on the interfacial integrity between cavity wall and composite restoration. Methods: Two class II slot preparations were done in 10 primary teeth either with SonicSys® or with a conventional bur. The cavities were filled using an adhesive system. One layer of a flowable composite and one layer of a condensable composite were applied. The specimens were analyzed by confocal laser scanning microscopy. Results: In the SonicSys® group the mean thickness of the hybrid layer was 6.12 (0.60) μm; in the control group it was 6.04 (0.63) μm. The difference was not statistically significant. Two fractures were observed in one to…

Materials scienceComposite numberAnalytical chemistryComposite ResinsDental High-Speed EquipmentStatistics NonparametricDentinmedicineFlowable CompositeHumansGeneral Materials ScienceUltrasonicsComposite materialTooth DeciduousDental Restoration PermanentGeneral DentistryDental LeakageMicroscopy ConfocalEnamel paintDental BondingAdhesionBevelResin CementsDentin Permeabilitymedicine.anatomical_structureMechanics of Materialsvisual_artDentin-Bonding Agentsvisual_art.visual_art_mediumDental Cavity PreparationLayer (electronics)Cavity wallDental materials : official publication of the Academy of Dental Materials
researchProduct

Effect of aluminum chloride hemostatic agent on microleakage of class V composite resin restorations bonded with all-in-one adhesive

2012

Objectives: Since hemostatic agents can induce changes on enamel and dentin surfaces and influence composite resin adhesion, the aim of the present study was to evaluate the effect of the aluminum chloride hemostatic agent on the gingival margin microleakage of class V (Cl V) composite resin restorations bonded with all-in-one adhesive. Study design: Cl V cavities were prepared on the buccal surfaces of 60 sound bovine permanent incisors. Gingival margins of the cavities were placed 1.5 mm apical to the cemento-enamel junction (CEJ). The teeth were randomly divided into two groups of 30. In group 1, the cavities were restored without the application of a hemostatic agent; in group 2, the ca…

Materials scienceComposite numberDentistryDental CementsDental bondingIn Vitro TechniquesComposite Resinsstomatognathic systemChloridesDental cementClinical and Experimental DentistryDentinmedicineAluminum ChlorideAnimalsAluminum CompoundsGeneral DentistryAstringentsDental LeakageHemostatic AgentEnamel paintbusiness.industryDental Bonding:CIENCIAS MÉDICAS [UNESCO]medicine.anatomical_structureOtorhinolaryngologyvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumSurgeryResearch-ArticleCattleAdhesivebusinessGingival marginMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Influence of cavity preparation technique (rotary vs. ultrasonic) on microleakage and marginal fit of six end-root filling materials

2010

Objectives: To evaluate in vitro the effect of cavity preparation with microburs and diamond-coated ultrasonic tips on the microleakage and marginal fit of six end-root filling materials. Study Design. The following materials were assessed: amalgam (Amalcap), zinc oxide eugenol (IRM), glass ionomer (Vitrebond), compomer (Cavalite), mineral particle aggregate (MTA) and composite (Clearfil). Cavity preparation was performed with microburs or diamond ultrasonic tips in single-root teeth. The seal was evaluated in two experiments: a microleakage assay on the passage of dye to the interface; and a scanning electron microscopy study and analysis of epoxy resin replicas, measuring the size of gaps…

Materials scienceComposite numberGlass ionomer cementDentistryHermetic seallaw.inventionRoot Canal Filling Materialschemistry.chemical_compoundlawRoot fillingUltrasonicsComposite materialGeneral DentistryDental Leakagebusiness.industryEpoxy:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryZinc oxide eugenolvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumSurgeryUltrasonic sensorDental Cavity PreparationbusinessCavity wall
researchProduct

Effect of bleaching agents on sealing properties of different intraorifice barriers and root filling materials

2012

Objective: To evaluate the effect of intracoronal bleaching agents on the sealing properties of different intraorifice barriers and root filling materials. Study Design: The root canals of extracted human premolars (n=180) were prepared by using System GT rotary files and filled with either gutta-percha+AH Plus or Resilon+Epiphany sealer. In both groups, the coronal 3mm of root filling was removed and replaced with one of the following materials applied as intraorifice barriers (n=30/group): 1. ProProot-MTA; 2. Conventional Glass ionomer cement; and 3. Hybrid resin composite. In each subgroup, intracoronal bleaching was performed using either sodium perborate with distilled water or 35% hyd…

Materials scienceGlass ionomer cementDentistryEndodonticsRoot Canal Filling MaterialsBleaching Agentschemistry.chemical_compoundMaterials TestingRoot fillingHumansBicuspidComposite materialHydrogen peroxideFluid filtrationGeneral DentistryLeakage (electronics)Dental Leakagebusiness.industry:CIENCIAS MÉDICAS [UNESCO]Epiphany sealerOtorhinolaryngologychemistryDistilled waterUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerySodium perboratebusiness
researchProduct

Incident angle effect on heavy ion induced reverse leakage current in SiC Schottky diodes

2016

Heavy-ion induced degradation in the reverse leakage current of SiC Schottky power diodes shows distinct dependence on the angle of incidence. TCAD simulations have been used to study the physical mechanisms involved.

Materials scienceSchottky barrierchemistry.chemical_elementSchottky diodes01 natural sciencesIonpower semiconductor devicesReverse leakage currentchemistry.chemical_compoundXenonsilicon carbide0103 physical sciencesSilicon carbidecurrent-voltage characteristicsDiode010302 applied physicsta114ta213010308 nuclear & particles physicsbusiness.industrySchottky diodeAngle of incidencemodelingchemistryOptoelectronicsbusinession radiation effects
researchProduct

Improvement of IPMSM performance through a mixed radial-tangential rotor structure

2010

In this paper an IPMSM (Interior Permanent Magnet Synchronous Motor) rotor configuration optimization is proposed in order to increase the performances in terms of torque, limiting at the same time the rotor leakage flux. The final mixed radial and tangential rotor configuration here proposed and described determines a reduction in PM material quantity of about 25% compared to a tangential IPMSM one with the same dimension and weight, together with an increase of the motoring torque of about 50%. Some simulation carried out by using a FEM software and a comparative analysis with two traditional IPMSMs rotor configurations show that a significant improvement can be achieved with limited chan…

Materials scienceSquirrel-cage rotorStatorRotor (electric)Magnetic flux leakageSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciWound rotor motorlaw.inventionMagnetic coreControl theorylawIPMSM Permanent magnets (PM) RotorTorqueSynchronous motor2010 IEEE International Symposium on Industrial Electronics
researchProduct

Long-term sealing ability of GuttaFlow versus Ah Plus using different obturation techniques.

2010

Objective. To compare the long-term sealing ability of GuttaFlow® using different obturation techniques. Study Design. Three hundred teeth, prepared with a crown-down technique, were divided into thirty experimental groups (n=10) to evaluate the apical and coronal leakage, at 3, 30 and 120 days, of lateral compaction gutta-percha + AH Plus?, lateral compaction gutta-percha + GuttaFlow®, single cone + AH Plus?, single cone + GuttaFlow®, and GuttaFlow® only. Results. Both coronal and apical leakage, at the three times of measurement, no significant differences were found among GuttaFlow® + lateral compaction gutta-percha and GuttaFlow® + single cone groups, whereas the only GuttaFlow® reached…

Materials scienceTime FactorsEpoxy ResinsCompactionApical leakage:CIENCIAS MÉDICAS [UNESCO]Silicon basedRoot Canal Filling MaterialsDrug CombinationsOtorhinolaryngologyRoot Canal ObturationCoronal planeUNESCO::CIENCIAS MÉDICASMaterials TestingHumansSurgerySingle coneDimethylpolysiloxanesGutta-PerchaGeneral DentistryLeakage (electronics)Biomedical engineeringMedicina oral, patologia oral y cirugia bucal
researchProduct