Search results for " Limit"
showing 10 items of 1716 documents
Physical Activity Scaled to Preferred Walking Speed as a Predictor of Walking Difficulty in Older Adults: A 2-Year Follow-up
2021
Abstract Background The usual accelerometry-based measures of physical activity (PA) are dependent on physical performance. We investigated the associations between PA relative to walking performance and the prevalence and incidence of early and advanced walking difficulties compared to generally used measures of PA. Methods Perceived walking difficulty was evaluated in 994 community-dwelling participants at baseline (age 75, 80, or 85 years) and 2 years later over 2 km (early difficulty) and 500 m (advanced difficulty). We used a thigh-mounted accelerometer to assess moderate-to-vigorous PA, daily mean acceleration, and relative PA as movement beyond the intensity of preferred walking spee…
Association between arterial stiffness and walking capacity in older adults
2022
Background and aim: Arterial stiffening – a process that is largely due to intimal thickening, collagen disposition or elastin fragmentation – significantly contributes to cardiovascular events and mortality. There is also some evidence that it may negatively affect physical function. This study aimed to evaluate whether arterial stiffness was associated with measures of walking capacity in a large, population-based sample of highly aged older adults.Methods: A population-based sample of 910 community-dwelling adults (aged 75, 80, or 85 years) were investigated in a cross-sectional observational study. Pulse wave velocity (PWV), a surrogate marker of arterial stiffness, was estimated based …
Preliminary data set to assess the performance of an outdoor membrane photobioreactor
2019
[EN] This data in brief (DIB) article is related to a Research article entitled 'Optimising an outdoor membrane photobioreactor for tertiary sewage treatment' [1]. Data related to the effect of substrate turbidity, the ammonium concentration at which the culture reaches nitrogen-deplete conditions and the microalgae growth rate under outdoor conditions is provided. Microalgae growth rates under different substrate turbidity were obtained to assess the reduction of the culture's light availability. Lab-scale experiments showed growth rates reductions of 22-44%. Respirometric tests were carried to know the limiting ammonium concentration in thismicroalgae-basedwastewater treatment system. Gro…
Occurrence and risk assessment of mycotoxins, acrylamide, and furan in Latvian beer.
2018
This work reports data on the occurrence of nine mycotoxins and two food processing contaminants - acrylamide and furan - in a total of 100 beers produced in Latvia. Mycotoxins were detected by high-performance liquid chromatography (HPLC) coupled with time-of-flight mass spectrometry, acrylamide by HPLC coupled with quadrupole-Orbitrap mass spectrometry, and furan by headspace gas chromatography-mass spectrometry. The most frequently occurring mycotoxins were HT-2 and deoxynivalenol (DON), which were detected in 52% and 51% of the analysed samples. The highest content was observed for DON, reaching the maximum of 248 µg kg-1. Furan was ubiquitous, and 74% of the samples contained acrylamid…
Determination of alcohols in essential oils by liquid chromatography with ultraviolet detection after chromogenic derivatization
2013
Abstract An HPLC-UV method to determine compounds having a hydroxyl functional group in plant essential oils is developed. The sample is diluted with 1,4-dioxane and the analytes are derivatized with phthalic anhydride. The derivatives (phthalates hemiesters) are separated on a C8 column using an acetonitrile (ACN)/water gradient. Separation conditions were optimized using the DryLab® method development software. For the alcohols and phenols present in mint and rose essential oils, optimization led to a ca. 40 min gradient time and a column temperature of 8 °C. The alcohol and its derivatives were identified using HPLC with mass spectrometry (MS) detection. A large sensitivity enhancement w…
The Classical Theory of Real Functions
1998
The first class of real functions we deal with in this chapter is the class of functions of locally finite variation. These functions are closely related to the real measures on B. Exploiting this connection would allow us to obtain the properties of these functions from the general results in Chapter 4. But the path we follow here is a more direct one which applies the theory of vector lattices. The link with the measures on B will be established in the next section.
Statistical Mechanics of the sine-Gorden Field: Part II
1985
From the work of the Part I we are now in a position to address ourselves to the main problem posed in these lectures — the evaluation of Z, (1.11), for the s-G field after canonical transformation to the action-angle variables (4.27).
Characterization and quantitation of mixtures of alkyl ether sulfates and carboxylic acids by capillary electrophoresis with indirect photometric det…
2003
The separation, characterization, and determination of mixtures of alkyl ether sulfates (AES) and fatty acids (C10-C16) in background electrolytes (BGEs) containing acetonitrile (ACN)-water mixtures is addressed. Due to inhibition of the ionization of the carboxylate groups, the migration time and the resolution between the fatty acids decreased when the water content of the BGE was reduced, but efficiency and resolution between the AES oligomers improved. The migration times increased and resolution improved by substituting 5% ACN by an equivalent amount of dioxane. A complete separation of the two surfactant classes, up to the AES oligomers with 8 ethylene oxide units (EOs) with respect t…
Determination of barbiturates in urine by micellar liquid chromatography and direct injection of sample.
2000
Abstract A liquid chromatographic procedure for the determination of six barbiturates (barbital, diallyl barbituric acid, phenobarbital, butabarbital, amobarbital and pentobarbital) in urine samples is described. The proposed system uses a Spherisorb octadecyl-silane ODS-2 C 18 analytical column and a guard column of similar characteristics. The UV detector was set at 240 nm. A study to select adequate composition of the micellar mobile phase for the separation of these compounds in urine samples is performed. Maximum resolution was achieved with a 0.07 M sodium dodecylsulphate-0.3% propanol at pH 7.4 eluent. Limits of detection at 240 nm were ranged between 0.13 μg ml −1 for diallyl barbit…