Search results for " Limit"
showing 10 items of 1716 documents
Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold
2021
Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…
Transmembrane electrochemistry of erythrocytes: Direct electrochemical test for detecting hemolysis in whole blood
2016
A rapid method for detecting hemolysis in whole blood based on a direct electrochemical assay either in venous blood and finger blood, respectively at glassy carbon and screen-printed graphite electrodes is described. The presence of hemolysis is detected from characteristic voltammetric signatures associated to Fe-heme units in healthy and hemolyzed erythrocytes. The voltammetric response of blood was also investigated using scanning electrochemical microscopy (SECM) and scanning tunneling microscopy (STM) and involved transmembrane electrochemistry of erythrocytes superimposed to molecular electrochemistry of heme-containing proteins and heme fragments in the plasma. Voltammetric testing …
Evaluation of Thin Film Microextraction for trace elemental analysis of liquid samples using LIBS detection
2021
An analytical methodology based in the combination of Thin Film Microextraction with Laser-induced Breakdown Spectroscopy (TFME-LIBS) was investigated, for the first time, for detection of Cu, Cr, Ni and Pb in aqueous solutions. In this methodology, the analytes were extracted in a thin film of adsorbent material deposited on a solid support, which was introduced in the sample to analyse. After extraction, the analytes retained in the adsorbent were analysed by LIBS. In order to obtain adsorbent films useful for the microextraction step, two different experimental procedures for film generation, denoted as Drop Casting Deposition and Mould Deposition, were evaluated. In both cases, graphene…
Graphene and ionic liquids new gel paste electrodes for caffeic acid quantification
2015
Abstract Graphene/ionic liquids nanocomposite gels were synthesized by an electrochemical etching approach and fully characterized under a morphological and structural point of view. For this purpose, several analytical techniques were applied, as HR-TEM/EDX (High Resolution-Transmission Electron Microscopy/Energy Dispersive X-Ray Analysis); FE-SEM/EDX (Field Emission-Scanning Electron Microscopy/Energy Dispersive X-Ray Analysis); XPS (X-Ray Photoelectron Spectroscopy); FT-IR (Fourier Transform-Infrared Spectroscopy) and electrochemical techniques. After the characterization study, nanocomposite-gel paste electrodes were assembled, exhibiting a selective and specific detection toward the ca…
Detection of fluorine using laser-induced breakdown spectroscopy and Raman spectroscopy
2017
In general, the detection of F and other halogens is challenging through conventional techniques. In this paper, various approaches for the qualitative and quantitative analysis of F using the laser-induced breakdown spectroscopy (LIBS) technique were demonstrated. In LIBS, fluorine detection can be realized by means of atomic lines and molecular bands. For the purposes of our experiment, two sets of pellets with various contents of CaF2, CaCO3 and cellulose were analyzed using a lab-based LIBS system under a He atmosphere. The fluorine atomic line at 685.60 nm was correlated with CaF signals proving their close relationship. Consequently, the limits of detection were determined for both an…
Optimization of selenium determination in human milk and whole blood by flow injection hydride atomic absorption spectrometry.
1998
abstract A flow injection hydride atomic absorption spectrometry (FI-HAAS) method was developed for determining selenium in human milk and whole blood after microwave digestion of the sample. The sample (2 mL human milk or 0.25 mL blood) was introduced into the microwave vessel with 1.5 mL HN03 and 0.25 mL H202 and 300 W (4 min) and 600 W (4 min) were applied. The digestion was completed by heating to 140 C (2-3 h). Se (VI) was reduced to Se (IV) with hydrochloric acid. The instrumental conditions for FI-HAAS (concentrations of reducing agent and carrier acid, flow rate of argon carrier gas, and sample volume injected) were optimized. The detection limit of the proposed method was 0.23 ng/m…
Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…
2015
A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…
Determination of low-molecular-mass aliphatic carboxylic acids and inorganic anions from kraft black liquors by ion chromatography.
2007
An ion chromatographic (IC) method with suppressed conductivity detection (CD) was developed and validated for the quantitative determination of several low-molecular-mass aliphatic mono- and dicarboxylic acids as their carboxylate anions together with some inorganic anions (chloride, sulfate, and thiosulfate) from kraft black liquors. To confirm the identification of some carboxylate anions which lack commercial model substances, a qualitative IC method with suppressed electrospray ionization mass spectrometry (ESI-MS) was also developed. The separations were performed on an IonPac AS 11-HC anion-exchange column operated at 25 degrees C within 25 min by a gradient elution with aqueous pota…
Atomic fluorescence determination of total and inorganic arsenic species in beer
2001
A simple and nearly direct procedure has been developed for the determination of As in beers, based on hydride generation and atomic fluorescence detection. Using 2 mol l−1 HCl with a carrier flow of 6 ml min−1, 3% m/v NaBH4 with a flow of 1.3 ml min−1, a reaction coil of 200 cm and an argon flow of 400 ml min−1, total arsenic in beer could be determined in samples diluted 1∶10 with a final concentration of 2 mol l−1 HCl, 1% m/v KI and 0.08% v/v of an antifoam agent. For the estimation of AsIII and AsV concentrations in beer samples, the difference between the analytical sensitivities of the fluorescence signals obtained for As hydride, without and with previous treatment of samples with KI…
Study on the sensitive and selective adsorption voltammetry of vanadium with antipyrylazo III (APA III)
1994
The sensitive and selective adsorption voltammetric determination of the vanadium(V)-antipyrylazoIII complex in HAc-NaAc solution is investigated. The V-complex is strongly adsorbed onto a stationary Hg-electrode and is reduced at a potential more negative than that corresponding to the reduction of its ligand. The conditions for determining vanadium are investigated and the mechanism of the reduction peak of the vanadium complex is discussed, as also the influence of foreign ions on the determination of vanadium. An at least 20-fold excess of foreign ions does not cause any interference. The detection limit is 4×10−10 mol/l V with 3 min enrichment time.