Search results for " Limit"
showing 10 items of 1716 documents
SiC Based Latching Current Limiter for High Voltage Space Power Distribution Systems
2018
This study presents a novel Latching Current Limiter topology, based on a N-channel Silicon Carbide (SiC) MOSFET as the main switching element. The design has been carried out using only discrete components, without digital controllers. This design has been validated by simulation and with a prototype. Tests have been performed at 1000V, modifying the limitation times, current-limiting values and eventually checking the proper operation of the system.
Single point incremental forming: An assessment of the progress and technology trends from 2005 to 2015
2017
The last decade has seen considerable interest in flexible forming processes. Among the upcoming flexible forming techniques, one that has captured a lot of interest is single point incremental forming (SPIF), where a flat sheet is incrementally deformed into a desired shape by the action of a tool that follows a defined toolpath conforming to the final part geometry. Research on SPIF in the last ten years has focused on defining the limits of this process, understanding the deformation mechanics and material behaviour and extending the process limits using various strategies. This paper captures the developments that have taken place over the last decade in academia and industry to highlig…
Cholesterol Content in Human Milk during Lactation: A Comparative Study of Enzymatic and Chromatographic Methods.
2018
This study validates a gas chromatography (GC) method for determining the sterol profile of human milk (HM) and compares it with an enzymatic-spectrophotometric (E-S) method. Good linearity ( r > 0.97) and low limits of detection and quantification were obtained with the GC method (<1.8 and <6 μg/100 g of HM, respectively). Suitable intra- and interassay precisions (all <18%) and satisfactory recovery percentages (80-109%) were obtained for both methods. In addition, both methodologies were used to assess cholesterol evolution in HM during lactation, showing a 50% decrease at 6 months versus colostrum. The E-S method overestimated cholesterol content by <20% versus the GC method. The result…
The utility of measuring tear film break-up time for prescribing contact lenses.
2017
Abstract Purpose To evaluate the clinical value of non-invasive keratograph tear film breakup time (NIKBUT) in the assessment of pre-corneal and pre-lens tear film quality for prescribing contact lenses (CLs). Methods Forty-six subjects aged 25.5 ± 4.3 (mean ± standard deviation) years were recruited. Visual acuity (VA), anterior eye health checks and NIKBUT were evaluated. On the following day, subjects were fitted with a daily Silicon Hydrogel (SiHy) CL in one eye and a Hydrogel (Hy) CL in the other. After four hours one material for both eyes was chosen based on a qualitative analysis which included VA, CL fitting and comfort. Information about the first and the mean NIKBUT was then cont…
Does telomere length predict decline in physical functioning in older twin sisters during an 11-year follow-up?
2016
Background: Leucocyte telomere length (LTL) is known to be associated with mortality, but its association with age-related decline in physical functioning and the development of disability is less clear. This study examined the associations between LTL and physical functioning, and investigated whether LTL predicts level of physical functioning over an 11- year follow-up. Methods: Older mono- (MZ) and dizygotic (DZ) twin sisters (n=386) participated in the study. Relative LTL was measured by qPCR at baseline. Physical functioning was measured by 6-min walking distance and level of physical activity (PA). Walking distance was measured at baseline and at 3-year follow-up. PA was assessed by q…
Reliable determination of new lipid peroxidation compounds as potential early Alzheimer Disease biomarkers.
2018
Lipid peroxidation plays an important role in Alzheimer Disease, so corresponding metabolites found in urine samples could be potential biomarkers. The aim of this work is to develop a reliable ultra-performance liquid chromatography-tandem mass spectrometry analytical method to determine a new set of lipid peroxidation compounds in urine samples. Excellent sensitivity was achieved with limits of detection between 0.08 and 17 nmol L-1, which renders this method suitable to monitor analytes concentrations in real samples. The method's precision was satisfactory with coefficients of variation around 5-17% (infra-day) and 8-19% (inter-day). The accuracy of the method was assessed by analysis o…
Sterols in infant formulas: validation of a gas chromatographic method.
2017
AbstractSterols are components present in the fat fraction of infant formulas (IFs). Their characterization is therefore of interest, though there are no official reference methods for their analysis in these matrices.Aim: To validate a gas chromatographic method with flame ionization detection for the determination of animal (cholesterol and desmosterol) and plant sterols (brassicasterol, campesterol, stigmasterol, β-sitosterol and sitostanol) found in IFs.All correlation coefficients obtained for the calibration curves of sterols studied were >0.99. Limits of detection (<1 μg/100 mL) and quantification (<4 μg/100 mL) are suitable for sterols determination in IFs. The within-assay precisio…
First report on the presence of Alloxan in bleached flour by LC-MS/MS method
2017
Abstract In this work the presence of Alloxan in bread, pastry and cake bleached flour was investigate in order to verify possible risk for consumers related to the use of chemicals for flour bleaching. A selective UHPLC–MS/MS method has been developed and validated for the purpose. Alloxan is one of the possible minor side products of oxidation after chemical bleaching of wheat flours, when several chemical agents are used. One hundred and seventy-five flour samples were analyzed for Alloxan determination. The validation of the method was performed in accordance with the ISO/IEC/EN 17025 for linearity, detection limit, quantification limit, accuracy, precision and ruggedness determination.…
Need for Deprescribing in Hospital Elderly Patients Discharged with a Limited Life Expectancy: The REPOSI Study
2019
<b><i>Objective:</i></b> Older people approaching the end of life are at a high risk for adverse drug reactions. Approaching the end of life should change the therapeutic aims, triggering a reduction in the number of drugs.<b><i></i></b>The main aim of this study is to describe the preventive and symptomatic drug treatments prescribed to patients discharged with a limited life expectancy from internal medicine and geriatric wards. The secondary aim was to describe the potentially severe drug-drug interactions (DDI). <b><i>Materials and Methods:</i></b> We analyzed Registry of Polytherapies Societa Italiana di Medicina I…
A New Frailty Score for Experimental Animals Based on the Clinical Phenotype: Inactivity as a Model of Frailty.
2016
The development of animal models to study human frailty is important to test interventions to be translated to the clinical practice. The aim of this work was to develop a score for frailty in experimental animals based in the human frailty phenotype. We also tested the effect of physical inactivity in the development of frailty as determined by our score. Male C57Bl/6J mice, individually caged, were randomly assigned to one of two groups: sedentary (inactive) or spontaneous wheel-runners. We compared the sedentary versus the active lifestyle in terms of frailty by evaluating the clinical criteria used in humans: unintentional weight loss; poor endurance (running time); slowness (running sp…