Search results for " MIC"
showing 10 items of 11429 documents
Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
2019
Background The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. Material and methods 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then e…
Two-phase dielectric polar structures in 0.1NBT-0.6ST-0.3PT solid solutions
2018
Abstract In this work we address the peculiarities of the macroscopic responses in ternary 0.1Na0·5Bi0·5TiO3-0.6SrTiO3-0.3PbTiO3 (0.1NBT-0.6ST-0.3PT) solid solutions. These solid solutions exhibit a spontaneous first order relaxor to normal ferroelectric phase transition. The phase transition is accompanied by a broad dielectric relaxation which expands over 10 orders of magnitude in frequency just above the phase transition temperature. The temperature dependence of polarization shows that non-zero net polarization persists above the phase transition temperature. Below the phase transition temperature, it is not possible to describe the temperature dependence of polarization with a power l…
Dielectric behaviour of BaTi1-xZrxO3ceramics obtained by means of a solid state and mechanochemical synthesis
2016
ABSTRACTIn this study the comparison of dielectric behaviour of BaTi1-xZrxO3 (BTZx) ceramic samples prepared by means of a solid state and mechanochemical synthesis was presented. A single phase of perovskite structure was identified in the samples at room temperature. No significant impurities were detected in an EDS spectrum and the samples had a good stoichiometric ratio. The morphology of the investigated samples was characterized by a scanning electron microscopy (SEM). The investigation of dielectric properties of the BTZx samples within the temperature range from 140 K to 600 K was performed by means of a dielectric spectroscopy method at the frequency ranging from 0.1 Hz to 10 MHz. …
Formation of translucent nanostructured zirconia ceramics
2021
Abstract In this work the mechanisms that affect the optical transparency of nanostructured translucent ZrO2 ceramics are studied. The translucent ceramic samples were obtained from a low agglomeration nanosized powder at low pressure and low temperature sintering. Even low pressures cause structural changes and defect creation in the nanocrystals. Annealing was used to study the grain formation, structure and impact of defects. Significant changes in translucency were observed with increase in pore size. In order to further understand the defect creation, the obtained ceramics were doped with Er3+ ions and studied optically. Photoluminescence studies revealed a change in the ratio of green…
Microfabricated high temperature sensing platform dedicated to scanning thermal microscopy (SThM)
2018
Abstract The monitoring of heat flux is becoming more and more critical for many materials and structures approaching nanometric dimensions. Scanning Thermal Microscopy (SThM) is one of the tools available for thermal measurement at the nanoscale and requires calibration. Here we report on a micro-hotplate device made of a platinum heater suspended on thin silicon nitride (SiN) membranes integrating specific features for SThM calibration. These heated reference samples can include a localized resistive temperature sensors (RTD) or standalone platinum membranes (typically 10 × 10 μm2) on which the temperature can be measured precisely. This functional area is dedicated to (1) estimate the th…
Simplified feedback control system for scanning tunneling microscopy
2021
A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few \AA. Often, the tunneling current between tip and sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here we discuss another approach, using a computer and data acquisition thr…
Effect of surface disorder on the domain structure of PLZT ceramics
2017
ABSTRACTPb1-xLax(Zr0.65Ti0.35)1-x/4O3 (PLZT x/65/35) ceramics were studied by Piezoresponse Force Microscopy in order to understand the origin of domain structure as a function of La content. We show that the domain topology is mainly determined by the composition and grain size. The characteristic correlation length decreases with increasing La content, being sensitive also to the synthesis method. The behavior of the correlation length is linked to the macroscopic properties, showing a strong increase of disorder with La doping. The roughness exponent for the domain wall in PLZT 9/65/35 is close to 2/3 indicating 1D character of domain walls in relaxors.
Optical studies of MBE-grown InN nanocolumns: Evidence of surface electron accumulation
2009
Stealth dicing with ultrafast Bessel beams with engineered transverse profiles
2017
International audience; We investigate high-speed glass cleaving with ultrafast laser beams with engineered transverse intensity profile. We achieve accuracy of ~ 1 µm at 25 mm/s and drastically enhance cleavability compared to standard Bessel beams.
A New LA ‐ ICP ‐ MS Method for Ti in Quartz: Implications and Application to High Pressure Rutile‐Quartz Veins from the Czech Erzgebirge
2016
Experimental determination of the pressure and temperature controls on Ti solubility in quartz provides a calibration of the Ti-in-quartz (TitaniQ) geothermometer applicable to geological conditions up to ~ 20 kbar. We present a new method for determining 48Ti mass fractions in quartz by LA-ICP-MS at the 1 μg g−1 level, relevant to quartz in HP-LT terranes. We suggest that natural quartz such as the low-CL rims of the Bishop Tuff quartz (determined by EPMA; 41 ± 2 μg g−1 Ti, 2s) is more suitable than NIST reference glasses as a reference material for low Ti mass fractions because matrix effects are limited, Ca isobaric interferences are avoided, and polyatomic interferences at mass 48 are i…