Search results for " Magnetic resonance"
showing 10 items of 2317 documents
Multislice multiecho T2* cardiac magnetic resonance for the detection of heterogeneous myocardial iron distribution in thalassaemia patients
2009
The present study investigated myocardial T2* heterogeneity in thalassaemia major (TM) patients by cardiac magnetic resonance (CMR), to determine whether is related to inhomogeneous iron overload distribution. A total of 230 TM patients consecutively referred to our laboratory were studied retrospectively. Three short-axis views (basal, medium and apical) of the left ventricle (LV) were obtained by multislice multiecho T2* CMR. T2* segmental distribution was mapped on a 16-segment LV model. The level of heterogeneity of the T2* segmental distribution, evaluated by the coefficient of variation (CoV), was compared with that of a surrogate data set, to determine whether the inhomogeneous segme…
Surprise: Unexpected Action Execution and Unexpected Inhibition Recruit the Same Fronto-Basal-Ganglia Network.
2020
Unexpected and thus surprising events are omnipresent and oftentimes require adaptive behavior such as unexpected inhibition or unexpected action. The current theory of unexpected events suggests that such unexpected events just like global stopping recruit a fronto-basal-ganglia network. A global suppressive effect impacting ongoing motor responses and cognition is specifically attributed to the subthalamic nucleus (STN). Previous studies either used separate tasks or presented unexpected, task-unrelated stimuli during response inhibition tasks to relate the neural signature of unexpected events to that of stopping. Here, we aimed to test these predictions using a within task design with i…
Amplitudes of laser evoked potential recorded from primary somatosensory, parasylvian and medial frontal cortex are graded with stimulus intensity
2003
Intensity encoding of painful stimuli in many brain regions has been suggested by imaging studies which cannot measure electrical activity of the brain directly. We have now examined the effect of laser stimulus intensity (three energy levels) on laser evoked potentials (LEPs) recorded directly from the human primary somatosensory (SI), parasylvian, and medial frontal cortical surfaces through subdural electrodes implanted for surgical treatment of medically intractable epilepsy. LEP N2* (early exogenous/stimulus-related potential) and LEP P2** (later endogenous potential) amplitudes were significantly related to the laser energy levels in all regions, although differences between regions w…
Beyond the amygdala: Linguistic threat modulates peri-sylvian semantic access cortices
2015
In this study, healthy volunteers were scanned using functional magnetic resonance imaging (fMRI) to investigate the neural systems involved in processing the threatening content conveyed via visually presented “threat words.” The neural responses elicited by these words were compared to those elicited by matched neutral control words. The results demonstrate that linguistic threat, when presented in written form, can selectively engage areas of lateral temporal and inferior frontal cortex, distinct from the core language areas implicated in aphasia. Additionally, linguistic threat modulates neural activity in visceral/emotional systems (amygdala, parahippocampal gyrus and periaqueductal gr…
Analysis of LDL and HDL size and number by nuclear magnetic resonance in a healthy working population: The LipoLab Study
2020
Background and aim Atherosclerosis is the underlying process in cardiovascular disease (CVD), the first cause of death in developed countries. We aimed to identify people with no known CVD and normal values of LDL-C and HDL-C, but with alterations in the number and size of lipoprotein particles (as measured by nuclear magnetic resonance [NMR]) and to analyse their sociodemographic, clinical and biochemical characteristics. Methods Cross-sectional study in occupational risks prevention centre in Castellon (Spain) in 2017 and 2018, in consecutively recruited adults (18-65 years) with no known CVD. Sociodemographic, clinical and biochemical variables were collected. Lipid profiles were analyse…
1H and 13C HR-MAS spectroscopy of intact biopsy samples ex vivo and in vivo 1H MRS study of human high grade gliomas.
2004
High-resolution magic angle spinning (HR-MAS) one- and two-dimensional 1H and 13C nuclear magnetic resonance (NMR) spectroscopy has been used to study intact glioblastoma (GBM) brain tumour tissue. The results were compared with in vitro chemical extract and in vivo spectra. The resolution of 1H one-dimensional, 1H TOCSY and 13C HSQC HR-MAS spectra is comparable to that obtained on perchloric extracts. 13C HSQC HR-MAS spectra have been particularly useful for the identification of 37 different metabolites in intact biopsy tumours, excluding water and DSS components. To our knowledge, this is the most detailed assignment of biochemical compounds obtained in intact human tissue, in particular…
Usefulness of quantitative peritumoural perfusion and proton spectroscopic magnetic resonance imaging evaluation in differentiating brain gliomas fro…
2016
Objectives The purpose of our study was to evaluate whether peritumoural perfusion weighted and proton spectroscopic magnetic resonance imaging can be used in differentiating between primary gliomas and solitary metastases. Methods Ten low-grade gliomas, eight high-grade gliomas and 10 metastases were prospectively evaluated with magnetic resonance imaging, dynamic susceptibility contrast enhanced perfusion imaging and single-voxel proton magnetic resonance spectroscopy before surgical resection or stereotactic biopsy. Maximal relative cerebral blood volume values were calculated drawing three regions of interest of 2 cm2 in the non-enhancing peritumoural areas. Maximal relative cerebral bl…
Nuclear magnetic resonance imaging with hyperpolarised helium-3
1996
Abstract Summary Background Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. Methods A volunteer inhaled hyperpolarised 3 He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 10 5 times larger than the polari…
Dynamics of brain activity underlying working memory for music in a naturalistic condition
2014
We aimed at determining the functional neuroanatomy of working memory (WM) recognition of musical motifs that occurs while listening to music by adopting a non-standard procedure. Western tonal music provides naturally occurring repetition and variation of motifs. These serve as WM triggers, thus allowing us to study the phenomenon of motif tracking within real music. Adopting a modern tango as stimulus, a behavioural test helped to identify the stimulus motifs and build a time-course regressor of WM neural responses. This regressor was then correlated with the participants' (musicians') functional magnetic resonance imaging (fMRI) signal obtained during a continuous listening condition. In…
Analyzing gastrocnemius EMG-activity and sway data from quiet and perturbed standing.
2007
In an experiment, we combined force plate measurements and surface EMG in studying quiet and perturbed standing, involving MS (Multiple sclerosis) and controls. The aim of this paper is to report the results thus obtained on the relation between filtered gastrocnemius (GA) EMG and the anterior-posterior center-of-pressure (A/P COP) coordinate. The main finding is the good correspondence between A/P COP and the filtered GA EMG in the low frequency range. The EMG envelope was calculated using a zero-lag filter. Combining this with time shifts around 250-350 ms produced a high correlation (85.5+/-8.4%) between the GA-EMG envelope and the A/P COP. This EMG-COP relation was closest when using a …