Search results for " Max"

showing 10 items of 878 documents

STOCHASTIC DYNAMICS OF TWO PICOPHYTOPLANKTON POPULATIONS IN A REAL MARINE ECOSYSTEM

2013

A stochastic reaction-diffusion-taxis model is analyzed to get the stationary distribution along water column of two species of picophytoplankton, that is picoeukaryotes and Prochlorococcus. The model is valid for weakly mixed waters, typical of the Mediterranean Sea. External random fluctuations are considered by adding a multiplicative Gaussian noise to the dynamical equation of the nutrient concentration. The statistical tests show that shape and magnitude of the theoretical concentration profile exhibit a good agreement with the experimental findings. Finally, we study the effects of seasonal variations on picophytoplankton groups, including an oscillating term in the auxiliary equation…

PhysicsGeneral Physics and AstronomySpatial ecology; Marine ecosystems; Phytoplankton dynamics; Deep chlorophyll maximum; Random processes; Stochastic differential equationsRandom processeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)OceanographyStochastic dynamicsMarine ecosystemStochastic differential equationsSpatial ecologyDeep chlorophyll maximumMarine ecosystemPhytoplankton dynamic
researchProduct

Thermal solitons along wires with flux-limited lateral exchange

2021

We obtain some exact solutions in the context of solitons, for heat conduction with inertia along a cylinder whose heat exchange with the environment is a non-linear function of the difference of temperatures of the cylinder and the environment, due to a flux-limiter behavior of the exchange. We study the consequences of heat transfer and information transfer along the wire, and we compare the situation with analogous solitons found in nonlinear lateral radiative exchange studied in some previous papers. We also find further exact solutions in terms of Weierstrass elliptic functions for the sake of completeness.

PhysicsHeat waves. Thermal solitons. Heat flux saturation. Maxwell-Cattaneo law. Radiative transfer. Auxiliary equation method. Flux limiters.media_common.quotation_subjectElliptic functionStatistical and Nonlinear PhysicsContext (language use)MechanicsInertiaThermal conductionNonlinear systemHeat transferRadiative transferCylinderMathematical Physicsmedia_common
researchProduct

HIGH-RESOLUTION FOURIER TRANSFORM SPECTROSCOPY OF LANTHANUM IN Ar DISCHARGE IN THE NEAR-INFRARED

2013

A high-resolution spectrum of lanthanum has been recorded by a Fourier Transform spectrometer in the wavelength range from 833 nm to 1666 nm (6000 cm{sup –1} to 12,000 cm{sup –1}) using as light source a hollow cathode lamp operated with argon as the discharge carrier gas. In total, 2386 spectral lines were detected in this region, of which 555 lines could be classified as La I transitions and 10 lines as La II transitions. All La II transitions and 534 of these La I transitions were classified for the first time, and 6 of the La II transitions and 433 of the classified La I transitions appear to be new lines, which could not be found in the literature. The corresponding energy level data o…

PhysicsHollow-cathode lampArgonNear-infrared spectroscopyResolution (electron density)Analytical chemistrychemistry.chemical_elementAstronomy and AstrophysicsFourier transform spectroscopySpectral linelaw.inventionFull width at half maximumNuclear magnetic resonancechemistrySpace and Planetary SciencelawHyperfine structureThe Astrophysical Journal Supplement Series
researchProduct

Analysis of the infrared Fourier transform spectrum of the Dyad of 116SnH4

1990

Abstract The FTIR spectrum of monoisotopic 116SnH4 has been recorded with the Bruker 120 HR interferometer at Giessen, West Germany, in the ν 2 ν 4 range extending from 600 to 850 cm−1. The resolution (FWHM) was 2.1 × 10−3 cm−1. The Dyad ν 2 ν 4 (0100, 0001) was analyzed using a sixth-order Hamiltonian. The analysis of infrared transitions enabled us to determine 10 ground state parameters, 9 ν2 parameters, 17 ν4 parameters, and 18 interaction parameters. Of 3800 calculated transitions assigned to observed lines, 1183 unblended lines have been selected for the data refinement. For J ≤ 19, the value of the standard deviation is of the order of magnitude of the estimated experimental accuracy…

PhysicsInfraredRotational transitionAtomic and Molecular Physics and Opticssymbols.namesakeFull width at half maximumFourier transformNuclear magnetic resonancesymbolsMonoisotopic massPhysical and Theoretical ChemistryAtomic physicsFourier transform infrared spectroscopyGround stateHamiltonian (quantum mechanics)SpectroscopyJournal of Molecular Spectroscopy
researchProduct

A Coherent Master Equation for active mode locking in lasers

2015

We present the derivation of a new master equation for active mode locking in lasers that fully takes into account the coherent effects of the light matter interaction through a peculiar adiabatic elimination technique. The coherent effects included in our model could be relevant to describe properly mode-locked semiconductor lasers where the standard Haus’ Master Equation predictions show some discrepancy with respect to the experimental results and can be included in the modelling of other mode locking techniques too.

PhysicsMaxwell-Bloch equationsmode lockingcoherent effects in mode locking; Maxwell-Bloch equations; mode locking; semiconductor lasers;Active modesemiconductor lasersLaserSemiconductor laser theorylaw.inventionMode-lockingcoherent effects in mode lockingModulationlawQuantum mechanicsElectric fieldQuantum electrodynamicsMaster equationAdiabatic process
researchProduct

A two-detector spectrometer for measurements of Doppler broadened positron annihilation spectra

2004

Abstract A two-detector spectrometer for measurements of Doppler broadened positron annihilation spectra has been constructed and tested. The energy difference of the annihilation quanta is measured in the analogue, not in the digital manner. The peak to background ratio in the measured spectra is of the order of 10 6 , the FWHM representing the energy resolution, equals to 1.1 keV , thus enabling the very subtle physical effects to be revealed. Some information on electronic structure of the investigated 3-d metals (Ti, V, Cr, Fe, Ni, Cu and Zn) has been determined using this spectrometer. It has been shown that the apparatus permits to detect the impurity-vacancy pairs in dilute nickel al…

PhysicsNuclear and High Energy PhysicsAnnihilationSpectrometerResolution (electron density)chemistry.chemical_elementElectronic structureSpectral lineNuclear physicssymbols.namesakeFull width at half maximumNickelchemistrysymbolsAtomic physicsInstrumentationDoppler effectNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Improving the Performance of Quasi-Hemispherical CdZnTe Detectors Using Infrared Stimulation

2012

The influence of monochromatic optical stimulation with wavelengths from 400 to 1100 nm on the characteristics of CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light with wavelengths of 870-900 nm close to the absorption edge of the CdZnTe significantly improves the performance of the detector at room temperature. Improvement can be achieved with low-intensity IR illumination at 1-300 μW depending on the chosen wavelength of illumination. Higher intensity illumination was observed to lead to the degradation of the detector's spectrometric characteristics. IR radiation was noted to influence the detector's sensitivity, changing the equili…

PhysicsNuclear and High Energy PhysicsInfraredbusiness.industryDetectorWide-bandgap semiconductorlaw.inventionWavelengthFull width at half maximumOpticsNuclear Energy and EngineeringAbsorption edgelawOptoelectronicsElectrical and Electronic EngineeringbusinessDiodeLight-emitting diodeIEEE Transactions on Nuclear Science
researchProduct

A broad iron line in the Chandra/HETG spectrum of 4U 1705-44

2004

We present preliminary results from a Chandra 30 ks observation of the atoll sourco 4U 1705 44. In particular we concentrate on the study of the iron Kα line, using the HEG spectrometer. The iron Kα line at ~ 6.6 keV is found to be intrinsically broad (FWHM ~ 1.7 keV); its width can be explained by reflection from a cold accretion disk extending down to ~ 17 km from the neutron star center or by Compton broadening in the hotter (~ 3 – 4 keV) corona.

PhysicsNuclear and High Energy PhysicsNeutron starFull width at half maximumSpectrometerAccretion discK-alphaAstronomyAstrophysicsAtomic and Molecular Physics and Optics
researchProduct

In-beam tests of scintillating fibre detectors at MAMI and at GSI

2008

The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The var…

PhysicsNuclear and High Energy PhysicsPhotomultiplierSpectrometerbusiness.industryDetectorFOS: Physical sciencesCharged particleParticle detectorNuclear physicsFull width at half maximumOpticsNuclear Experiment (nucl-ex)businessInstrumentationMicrotronNuclear ExperimentBeam (structure)
researchProduct

A time-differential Mössbauer emission spectrometer with high efficiency and high time resolution

1986

A high-efficiency, high rate-capability, computer-based measuring setup for Time-Differential Mossbauer Spectroscopy was constructed. Applying NaI(Tl) and plastic scintillators for the detection of the 14.4 keV and 122 keV γ-radiation respectively, a superior timing (2, 3 ns FWHM) was achieved by a “fast-fast-ultra fast” timing method developed for that purpose.

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsAnalytical chemistryTime resolutionScintillatorCondensed Matter PhysicsAtomic and Molecular Physics and OpticsFull width at half maximumMössbauer spectroscopyPhysical and Theoretical ChemistryThin filmSpectroscopyDifferential (mathematics)Emission SpectrometerHyperfine Interactions
researchProduct