Search results for " Measurement"

showing 10 items of 2341 documents

Foaming estimation tests in activated sludge systems.

2005

Persistent biological foaming phenomena in activated sludge systems due to excess of filamentous microorganisms with hydrophobic properties, such as GALO, Microthrix parvicella and others, are frequently reported everywhere. Nevertheless, even if the number of plants affected by this trouble is high, presently there are no suitable general methods to evaluate properly the phenomenon. This paper reports on the results of a series of foam tests (Scum Index, Foam Rating), of hydrophobicity measurements of activated sludge (mixed liquor and foam) and measurements of extension of aeration tank covered by foam surfaces. The data obtained by using the above indicated methods are clearly correlated…

Activated sludgeMaterials scienceWaste managementFilamentous microorganismsMicrothrix parvicellaEnvironmental ChemistryAquatic ScienceAerationTest measurementGeneral Environmental ScienceWater Science and Technology
researchProduct

Die bestimmung von sedimentationskoeffizient, diffusions-koeffizient und molekulargewicht von α-amylasen nach der methode des aktivitätstransportes

1965

Abstract Sedimentation and diffusion coefficients determined by optical methods on pure (crystallized) enzymes are compared with those obtained by activity measurements on the unpurified enzymes. On performing the experiments under suitable conditions, results of the two methods are in good agreement. The calculation of the molecular weights of the unpurified enzymes is somewhat uncertain because the partial specific volume in most cases is not accurately known.

Activity measurementsChromatographyMolecular massPartial specific volumeChemistryDiffusionPolymer chemistryBiochemistry Genetics and Molecular Biology (miscellaneous)Biochimica et Biophysica Acta (BBA) - Biophysics including Photosynthesis
researchProduct

Actual evapotranspiration assessment by means of a coupled energy/hydrologic balance model: Validation over an olive grove by means of scintillometry…

2010

Summary A coupled energy/hydrologic model was applied to simulate the exchange of energy and water in the soil–plant-atmosphere system (SPA). The model, which uses a “two-source” approach to estimate the energy fluxes, and the “force-restore” approach to represent the water balance, was validated by means of evapotranspiration measurements collected via scintillometry and soil moisture measurements collected via time domain reflectometry (TDR) in a Sicilian olive grove. The comparison between measured and estimated fluxes values at an hourly scale showed good agreement. Additional comparisons on a daily timescale confirmed the model’s applicability for quantifying crop water requirements. A…

Actual evapotranspirationHydrologyScintillometer measurementsMoistureScale (ratio)Settore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaEnergy balanceScintillometer measurementHydrologic balanceWater balanceHydrology (agriculture)EvapotranspirationActual evapotranspiration; Scintillometer measurements; Olive grove; Surface energy fluxes; Hydrologic balanceSoil waterOlive groveSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliEnvironmental scienceSurface energy fluxesSurface energy fluxeWater contentWater Science and TechnologyJournal of Hydrology
researchProduct

Portfolio performance evaluation with loss aversion

2011

In this paper we consider a loss-averse investor equipped with a specific, but still quite general, utility function motivated by behavioral finance. We show that, under certain concrete assumptions concerning the form of this utility, one can derive closed-form solutions for the investor's portfolio performance measure. We investigate the effects of loss aversion and demonstrate its important role in performance measurement. The framework presented in this paper also provides a sound theoretical foundation for all known performance measures based on partial moments of the distribution.

Actuarial sciencemedia_common.quotation_subjectDecision theoryBehavioral economicsMeasure (mathematics)Spectral risk measureLoss aversionEconometricsEconomicsPortfolioPerformance measurementFunction (engineering)General Economics Econometrics and FinanceFinancemedia_commonQuantitative Finance
researchProduct

Control of the production of oxygen intermediates of human polymorphonuclear leukocytes and monocytes by beta-adrenergic receptors.

1983

The control by beta-adrenergic receptors of the production of oxygen radicals by zymosan-stimulated human polymorphonuclear leukocytes (PMN) and monocytes (M phi) was studied in vitro by means of chemiluminescence. In addition we asked whether PMN and M phi exhibit differential sensitivity to beta-adrenergic stimulation. For beta-adrenergic stimulation we applied fenoterol ranging from 10(-5) to 10(-9) M x 2.7. We found a dose-dependent suppression of the production of oxygen radicals, the ID50 being approximately 10(-6) M both for PMN and M phi. By assessment of lactic dehydrogenase release a cytotoxic effect of the drug could be ruled out. When incubated together with the beta-adrenergic …

Adrenergic receptorFree RadicalsNeutrophilsImmunologychemistry.chemical_elementStimulationPropranololPharmacologyToxicologyOxygenMonocytesOxygen ConsumptionPhagocytosisReceptors Adrenergic betamedicineHumansReceptorFenoterolFenoterolPharmacologyAntagonistZymosanPropranololIn vitroOxygenchemistryBiochemistryLuminescent Measurementsmedicine.drugJournal of immunopharmacology
researchProduct

Application of jäntti's method to volumetric adsorption measurements

2004

Jantti introduced a method to calculate the adsorption equilibrium by measuring the actual adsorbed amount three times after a change to the gas pressure. By this method the experimental time for adsorption measurement can be considerably shortened. The procedure was developed for use in adsorption measurements where the adsorbed masses are directly measured with a balance. In the present paper we will demonstrate that the method is particularly useful in volumetric (manometric) measurements.

AdsorptionGas pressureChemistryAdsorption equilibriumPhysical chemistryThermodynamicsSorptionPhysical and Theoretical ChemistryCondensed Matter PhysicsFast measurementJournal of Thermal Analysis and Calorimetry
researchProduct

Development of a Brief Form of the Interpersonal Reactivity Index (B–IRI)

2016

ABSTRACTThe Interpersonal Reactivity Index (IRI) is a standardized self-report measure of disposition to empathic responsiveness for the general adult population (the domain for which it was developed), and for the general adolescent population. The IRI has a number of problems, however, including some uncertainty about its factor structure, low reliabilities, and poor readability of some items for people with limited literacy skills. To address these issues, we constructed an abbreviated form of the index, the Brief IRI (B–IRI). Three studies demonstrated that this 16-item B–IRI has a clear and coherent factor structure, adequate internal consistency, measurement invariance across gender a…

Adult050103 clinical psychologyIndex (economics)AdolescentPsychometricsHealth Toxicology and MutagenesisAdult population050109 social psychologyPersonality Assessmenturologic and male genital diseasesFactor structureDevelopmental psychologyArts and Humanities (miscellaneous)HumansInterpersonal Relations0501 psychology and cognitive sciencesMeasurement invariancecardiovascular diseasesClinical Psychology; Arts and Humanities (miscellaneous)urogenital systemfungi05 social sciencesSettore M-PSI/03 - PsicometriaReproducibility of ResultsConstruct validityDispositionfemale genital diseases and pregnancy complicationsReadabilityClinical PsychologyInterpersonal Reactivity IndexEmpathyPsychologyIRI brief form development measurement invariance confirmatory factor analysis validity construct
researchProduct

Impact of physical exercise on sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system in people with Ty…

2019

AIMS To evaluate the sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system using reference blood glucose levels during moderate-intensity exercise while on either full or reduced basal insulin dose in people with Type 1 diabetes. METHODS Ten participants with Type 1 diabetes [four women, mean ± sd age 31.4 ± 9.0 years, BMI 25.5±3.8 kg/m2 , HbA1c 55±7 mmol/mol (7.2±0.6%)] exercised on a cycle ergometer for 55 min at a moderate intensity for 5 consecutive days at the clinical research facility, while receiving either their usual or a 75% basal insulin dose. After a 4-week washout period, participants performed the second exercise period having sw…

AdultBlood GlucoseMalemedicine.medical_specialtyEndocrinology Diabetes and Metabolism030209 endocrinology & metabolismPhysical exerciseBiosensing Techniques03 medical and health sciencesYoung Adult0302 clinical medicineEndocrinologyInsulin Infusion SystemsInterquartile rangePredictive Value of TestsDiabetes mellitusInternal medicineInternal MedicinemedicineHumansInsulin030212 general & internal medicineExercise physiologyBlood Glucose MeasurementExerciseType 1 diabetesCross-Over StudiesDose-Response Relationship Drugbusiness.industryBlood Glucose Self-MonitoringEquipment Designmedicine.diseaseCrossover studyDiabetes Mellitus Type 1Equipment and SuppliesPredictive value of testsCardiologyFemalebusiness
researchProduct

Evaluation of CGMS® During Rapid Blood Glucose Changes in Patients with Type 1 Diabetes

2006

CGMS (Medtronic Minimed, Duesseldorf, Germany) allows continuous glucose monitoring. Recent studies with invasive monitoring techniques revealed discrepancies in blood glucose measurements obtained from different anatomical sites compared with those from the fingertip. The aim of this study was to investigate the CGMS and a device for alternative site testing (AST) during dynamic blood glucose changes and to compare these results with fingertip measurements.Twelve patients with type 1 diabetes (seven women, five men; age, 33.3 +/- 8.7 years) received a 75-g oral glucose load. Insulin was applied intravenously (rapid glucose decline) or subcutaneously (moderate glucose decline) in a dosage b…

AdultBlood GlucoseMalemedicine.medical_specialtyInjections SubcutaneousEndocrinology Diabetes and Metabolismmedicine.medical_treatmentEndocrinologyForearmDiabetes mellitusmedicineHumansHypoglycemic AgentsInsulinIn patientBlood Glucose MeasurementType 1 diabetesbusiness.industryBlood Glucose Self-MonitoringSite testingInsulinGlucose MeasurementMiddle Agedmedicine.diseaseSurgeryMedical Laboratory TechnologyDiabetes Mellitus Type 1medicine.anatomical_structureAnesthesiaInjections IntravenousFemalebusinessDiabetes Technology & Therapeutics
researchProduct

Facilitating cartilage volume measurement using MRI.

2010

To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses.Ten knees were scanned with a 1.5T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5mm, 3.0mm and 5.0mm slices using the Argus software application. Accuracy and time effectiveness served as control parameters.Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6+/-127.7s and 379.1+/-117.6s to 214.9+/-109.9s and 213.9+/-102.2s to 122.1+/-60.1s and 126.8+/-56.2s and for the medial tibial platea…

AdultCartilage ArticularMaleKnee JointLateral tibial plateauArticular cartilageYoung AdultVolume measurementImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingControl parametersObserver VariationTibiabusiness.industryCartilageGeneral MedicineAnatomyMagnetic Resonance Imagingmedicine.anatomical_structureFemalebusinessVolume (compression)Biomedical engineeringGradient echoEuropean journal of radiology
researchProduct