Search results for " Medical imaging"

showing 10 items of 1067 documents

Optimization of Labeling PSMAHBED with Ethanol-Postprocessed 68Ga and Its Quality Control Systems

2017

Radiolabeling of the prostate-specific membrane antigen (PSMA) inhibitor Glu-NH-CO-NH-Lys(Ahx) using the 68Ga chelator HBED-CC (PSMAHBED) allows imaging of prostate cancer lesions because of high expression of PSMA in prostate carcinoma cells and in bone metastases and lymph nodes related to the disease. The aim of this work was to optimize labeling of 68Ga-PSMAHBED using the efficient cation-exchange postprocessing of 68Ga as well as the development of a thin-layer chromatography (TLC)-based quality control system. Methods: Labeling was optimized for online ethanol-postprocessed 68Ga eluate investigating various parameters, such as buffer molarity (0.1-1 M), temperature (25°C-90°C), tracer…

ChromatographyMolar concentrationElutionSilica gelProstate carcinomaClinical routine030218 nuclear medicine & medical imaging03 medical and health scienceschemistry.chemical_compound0302 clinical medicinechemistryQuality control system030220 oncology & carcinogenesisRadiology Nuclear Medicine and imagingMembrane antigenJournal of Nuclear Medicine
researchProduct

Novel bifunctional DATA chelator for quick access to site-directed PET 68Ga-radiotracers: preclinical proof-of-principle with [Tyr3]octreotide

2017

Molecular imaging of tumors with the PET radionuclide 68Ga has gained momentum in clinical oncology due to the expanding availability of commercial 68Ge/68Ga-generators in combination with state-of-the-art PET/CT and PET/MRI hybrid imaging systems. Concurrently, interesting peptide-based or small-size vectors have been developed for theranostic use in cancer patients. Owing to the short half-life of 68Ga (t1/2 = 67.7 min) and the sensitivity of many targeting biomolecules, labeling and kit reconstitution in mild conditions allowing for quick access to ready-for-injection PET-tracers are highly desirable. The novel DATA ((6-pentanoic acid)-6-(amino)methy-1,4-diazepinetriacetate) chelator pre…

Clinical OncologyOctreotideNanotechnology010402 general chemistry01 natural sciences030218 nuclear medicine & medical imaging0104 chemical sciencesInorganic Chemistry03 medical and health scienceschemistry.chemical_compound0302 clinical medicinechemistryCancer researchmedicineBifunctional chelatorChelationMolecular imagingBifunctionalClearancemedicine.drugDalton Transactions
researchProduct

Improving color correction across camera and illumination changes by contextual sample selection

2012

International audience; In many tasks of machine vision applications, it is important that recorded colors remain constant, in the real world scene, even under changes of the illuminants and the cameras. Contrary to the human vision system, a machine vision system exhibits inadequate adaptability to the variation of lighting conditions. Automatic white bal- ance control available in commercial cameras is not sufficient to pro- vide reproducible color classification. We address this problem of color constancy on a large image database acquired with varying digi- tal cameras and lighting conditions. A device-independent color repre- sentation may be obtained by applying a chromatic adaptation…

Color Constancy[ INFO.INFO-TS ] Computer Science [cs]/Signal and Image ProcessingColor normalizationMachine visionComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONColor balance02 engineering and technology[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine[INFO.INFO-TS]Computer Science [cs]/Signal and Image Processing0202 electrical engineering electronic engineering information engineeringComputer visionElectrical and Electronic EngineeringContextual improvement. Medical applicationsColor constancybusiness.industryColor correctionImage segmentationAtomic and Molecular Physics and OpticsComputer Science ApplicationsChromatic adaptationRGB color model020201 artificial intelligence & image processingArtificial intelligenceSPIEbusiness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing
researchProduct

Semantic and topological classification of images in magnetically guided capsule endoscopy

2012

International audience; Magnetically-guided capsule endoscopy (MGCE) is a nascent technology with the goal to allow the steering of a capsule endoscope inside a water filled stomach through an external magnetic field. We developed a classification cascade for MGCE images with groups images in semantic and topological categories. Results can be used in a post-procedure review or as a starting point for algorithms classifying pathologies. The first semantic classification step discards over-/under-exposed images as well as images with a large amount of debris. The second topological classification step groups images with respect to their position in the upper gastrointestinal tract (mouth, es…

Color histogramComputer scienceFeature extraction[INFO.INFO-IM] Computer Science [cs]/Medical ImagingImage processingFundus (eye)Content-based image retrieval030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineDiscriminative modelCapsule endoscopylaw[INFO.INFO-IM]Computer Science [cs]/Medical ImagingmedicineUpper gastrointestinalComputer visionSegmentationAntrumContextual image classification[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryStomachmedicine.anatomical_structureFeature (computer vision)Duodenum030211 gastroenterology & hepatologyArtificial intelligencebusiness
researchProduct

Determination of optimal fluoroscopic angulations for aorto-coronary ostial interventions from coronary computed tomography angiography.

2020

Abstract Background An optimal aorto-coronary angiographic projection, characterized by an orthogonal visualization of the proximal coronary artery, is crucial for interventional success. We determined the distribution of optimal C-arm positions and assessed their feasibility by invasive coronary angiography. Methods Orthogonal aorto-coronary ostial angulations were determined in 310 CT data sets. In 100 patients undergoing subsequent invasive angiography, we assessed if the CT-predicted angulations were achievable by the C-arm system. If the predicted projection was not achievable due to mechanical constraints of the C-arm system, the most close, achievable angulation was determined. Patie…

Computed Tomography Angiography030204 cardiovascular system & hematologyBody weightCoronary Angiography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePredictive Value of TestsMedicineHumansRadiology Nuclear Medicine and imagingComputed tomography angiographymedicine.diagnostic_testbusiness.industryCoronary computed tomography angiographyInvasive coronary angiographyCoronary ostiumOstiummedicine.anatomical_structureFluoroscopyAngiographycardiovascular systemCardiology and Cardiovascular MedicinebusinessNuclear medicineTomography X-Ray ComputedArteryJournal of cardiovascular computed tomography
researchProduct

Simple computation of the approximated modulation transfer function (MTF) using spreadsheet-software: method and evaluation in five maxillofacial CBC…

2019

OBJECTIVES: To develop a simple way to compute the approximated modulation transfer function (MTF) manually using conventional spreadsheet software. METHODS: Basing on an edge-image a method was developed, facilitating computation of the edge spread and line spread function in open-source spreadsheet software (Gnumeric; http://projects.gnome.org/gnumeric/downloads.shtml). By means of the integrated fast Fourier transformation Fourier coefficients are obtained from the line spread function which can then be plotted vs spatial frequency to obtain MTF-plots. For the experimental evaluation an edge test object was exposed in five commercial CBCT devices for maxillofacial applications. RESULTS: …

Computer science030218 nuclear medicine & medical imaging03 medical and health sciencessymbols.namesake0302 clinical medicineTechnical ReportSimple (abstract algebra)Optical transfer functionRadiography DentalHumansRadiology Nuclear Medicine and imagingGeneral DentistryDigital signal processingSimple computationbusiness.industrySpreadsheet softwarePhantoms ImagingComputer Science::Software EngineeringReproducibility of Results030206 dentistryGeneral MedicineSpiral Cone-Beam Computed TomographyRadiographic Image EnhancementFourier transformOtorhinolaryngologysymbolsbusinessAlgorithmSoftware
researchProduct

Automated prostate gland segmentation based on an unsupervised fuzzy C-means clustering technique using multispectral T1w and T2w MR imaging

2017

Prostate imaging analysis is difficult in diagnosis, therapy, and staging of prostate cancer. In clinical practice, Magnetic Resonance Imaging (MRI) is increasingly used thanks to its morphologic and functional capabilities. However, manual detection and delineation of prostate gland on multispectral MRI data is currently a time-expensive and operator-dependent procedure. Efficient computer-assisted segmentation approaches are not yet able to address these issues, but rather have the potential to do so. In this paper, a novel automatic prostate MR image segmentation method based on the Fuzzy C-Means (FCM) clustering algorithm, which enables multispectral T1-weighted (T1w) and T2-weighted (T…

Computer scienceAutomated segmentation; Fuzzy C-Means clustering; Multispectral MR imaging; Prostate cancer; Prostate gland; Unsupervised machine learningMultispectral image02 engineering and technologyautomated segmentation; multispectral MR imaging; prostate gland; prostate cancer; unsupervised Machine Learning; Fuzzy C-Means clustering030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineProstate0202 electrical engineering electronic engineering information engineeringmedicineComputer visionSegmentationautomated segmentationunsupervised Machine LearningCluster analysisSettore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.diagnostic_testbusiness.industryINF/01 - INFORMATICAMagnetic resonance imagingmedicine.diseaseprostate cancerFuzzy C-Means clusteringmultispectral MR imagingmedicine.anatomical_structureUnsupervised learning020201 artificial intelligence & image processingArtificial intelligencebusinessprostate glandInformation SystemsMultispectral segmentation
researchProduct

Iteratively Learning a Liver Segmentation Using Probabilistic Atlases: Preliminary Results

2016

This works deals with the concept of liver segmentation by using a priori information based on probabilistic atlases and segmentation learning based of previous steps. A probabilistic atlas is here understood as a probability or membership map that tells how likely is that a point belongs to a shape drawn from the shape distribution at hand. We devise a procedure to segment Perfusion Magnetic Resonance liver images that combines both: a probabilistic atlas of the liver and a segmentation algorithm based on global information of previous simpler segmentation steps, local information from close segmented slices and finally a mathematical morphology procedure, namely viscous reconstruction, to…

Computer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONScale-space segmentation02 engineering and technologyIterative reconstructionMathematical morphology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine0202 electrical engineering electronic engineering information engineeringmedicineSegmentationComputer visionComputingMethodologies_COMPUTERGRAPHICSmedicine.diagnostic_testSegmentation-based object categorizationbusiness.industryProbabilistic logicMagnetic resonance imagingPattern recognitionImage segmentationComputer Science::Computer Vision and Pattern Recognition020201 artificial intelligence & image processingArtificial intelligencebusinessPerfusion2016 15th IEEE International Conference on Machine Learning and Applications (ICMLA)
researchProduct

Improving Lossless Image Compression with Contextual Memory

2019

With the increased use of image acquisition devices, including cameras and medical imaging instruments, the amount of information ready for long term storage is also growing. In this paper we give a detailed description of the state-of-the-art lossless compression software PAQ8PX applied to grayscale image compression. We propose a new online learning algorithm for predicting the probability of bits from a stream. We then proceed to integrate the algorithm into PAQ8PX&rsquo

Computer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONgeometric weightingData_CODINGANDINFORMATIONTHEORY02 engineering and technologylcsh:TechnologylosslessGrayscale030218 nuclear medicine & medical imagingImage (mathematics)lcsh:Chemistry03 medical and health sciences0302 clinical medicineProbabilistic methodSoftware0202 electrical engineering electronic engineering information engineeringprobabilistic methodGeneral Materials Sciencelcsh:QH301-705.5InstrumentationFluid Flow and Transfer ProcessesLossless compressioncontextual informationlcsh:Tbusiness.industryProcess Chemistry and TechnologyGeneral EngineeringEnsemble learninglcsh:QC1-999image compressionComputer Science ApplicationsTerm (time)lcsh:Biology (General)lcsh:QD1-999Computer engineeringlcsh:TA1-2040ensemble learning020201 artificial intelligence & image processinglcsh:Engineering (General). Civil engineering (General)businesslcsh:PhysicsImage compressionApplied Sciences
researchProduct

A Wavelet approach to extract main features from indirect immunofluorescence images

2019

A number of previous studies have shown that IIF image analysis requires complex and sometimes heterogeneous and diversified methods. Robust solutions can be proposed but they need to orchestrate several methods from low-level analysis up to more complex neural networks or SVM for data classification. The contribution intends to highlight the versatility of Wavelet Transform (WT) and their use in various levels of analysis for the classification of IIF images in order to develop a system capable of performing: image enhancement, ROI segmentation and object classification. Therefore, WT was adopted in the de-noise section, segmentation and classification. This analysis allows frequencies cha…

Computer scienceData classificationWavelet Transform02 engineering and technologyPattern Recognition030218 nuclear medicine & medical imaging03 medical and health sciencesSegmentation0302 clinical medicineWaveletRobustness (computer science)IIF dataset0202 electrical engineering electronic engineering information engineeringSegmentationMedical diagnosisSettore INF/01 - InformaticaArtificial neural networkbusiness.industryDenoiseWavelet transformPattern recognitionClassificationSupport vector machine020201 artificial intelligence & image processingArtificial intelligencebusinessProceedings of the 20th International Conference on Computer Systems and Technologies
researchProduct