Search results for " NOISE"
showing 10 items of 659 documents
Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques
2008
Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …
Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…
1992
In a previous paper, in which the experimental conditions of the present research are fully described (Parrot et al., this issue), heart rate (HR) was studied in 60 male and in 60 female subjects in response to a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), and an intermittent pink noise (R), all noises being emitted at the same LAeq = 75 dB for 15 min. Digital pulse level (PL) responses were concomitantly surveyed by the use of pulse oximetry, allowing continuous arterial oxygen saturation (SaO2) readings. An index of pulse reactivity (PRI) could be calculated. Arterial blood pressure was measured 7 times from the beginning to the end of each trial. At rest, within…
Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…
1992
This study aimed at comparing for their cardiovascular effects: a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), an intermittent pink noise (R). All noises were presented at the same LAeq = 75 dB for 15 min each. Some 120 subjects were divided into 8 subgroups of 15 subjects each: OM (men between 40 and 50 years of age), OF (women, same age range), YM (men, between 15 and 20 years of age), YF (women, same age range), AM (typically anxious men, 20–25 years of age), AF (typically anxious women, same age range), NM (typicall anxiety-free men, same age range), and NF (typically anxiety-free women, same age range). Heart rate (HR), digital pulse level, and arterial blood p…
Perceptual Performance as a Function of Intra-Cycle Cardiac Activity
1975
The purpose of the experiment was to test the hypothesis of a systematic change in perceptual performance within a single cardiac cycle due to the activity of the baroreceptors in carotid sinus. As an index of perceptual performance the ds-parameter from signal detection theory (TSD) was used. A 1000 Hz sine tone had to be detected in a background of white noise. Each of 4 subjects received on the average 4605 noise or noise plus tone stimuli distributed over 10 experimental sessions. When comparing performance during time intervals before and after baroreceptor activity onset no significant difference was found. Also, when tracing perceptual performance over the whole cardiac cycle in step…
Road Traffic Noise Exposure and Filled Prescriptions for Antihypertensive Medication:A Danish Cohort Study
2020
BACKGROUND: Epidemiological research on effects of transportation noise on incident hypertension is inconsistent. OBJECTIVES: We aimed to investigate whether residential road traffic noise increases the risk for hypertension. METHODS: In a population-based cohort of 57,053 individuals 50-64 years of age at enrollment, we identified 21,241 individuals who fulfilled our case definition of filling formula presented prescriptions and formula presented defined daily doses of antihypertensive drugs (AHTs) within a year, during a mean follow-up time of 14.0 y. Residential addresses from 1987 to 2016 were obtained from national registers, and road traffic noise at the most exposed façade as well as…
Experimental and methodological factors affecting test-retest reliability of amygdala BOLD responses.
2018
Previous studies reported poor to fair test-retest reliability of amygdala BOLD responses to emotional stimuli. However, these findings are very heterogeneous across and within studies. The present study sought to systematically examine experimental and methodological factors that contribute to this heterogeneity. Forty-six young subjects were scanned twice with a mean test-retest interval of 7 weeks. We compared amygdala reliability across three tasks: A face-matching task, passive viewing of emotional faces, and passive viewing of emotional scenes. We also explored whether extraction of physiological noise can affect the stability of amygdala responses. We assessed test-retest reliability…
Effect of nighttime aircraft noise exposure on endothelial function and stress hormone release in healthy adults.
2013
Aims Aircraft noise disturbs sleep, and long-term exposure has been shown to be associated with increases in the prevalence of hypertension and an overall increased risk for myocardial infarction. The exact mechanisms responsible for these cardiovascular effects remain unclear. Methods and results We performed a blinded field study in 75 healthy volunteers (mean age 26 years), who were exposed at home, in random order, to one control pattern (no noise) and two different noise scenarios [30 or 60 aircraft noise events per night with an average maximum sound pressure level (SPL) of 60 dB(A)] for one night each. We performed polygraphy during each study night. Noise caused a worsening in sleep…
Long-term exposure to transportation noise and risk for atrial fibrillation: A Danish nationwide cohort study.
2022
Background: Epidemiological studies have linked transportation noise and cardiovascular diseases, however, atrial fibrillation (AF) has received limited attention. We aimed to investigate the association between transportation noise and AF risk. Methods: Over the period 1990–2017 we estimated road and railway noise (L den) at the most and least exposed façades for all residential addresses across Denmark. We estimated time-weighted mean noise exposure for 3.6 million individuals age ≥35 years. Of these, 269,756 incident cases of AF were identified with a mean follow-up of 13.0 years. Analyses were conducted using Cox proportional hazards models with adjustment for individual and area-level …
Diltiazem for Prevention of Acoustical Trauma during Otologic Surgery
1995
100 patients were tested in a prospective, randomized, double-blinded study to assess the perioperative efficacy of a calcium channel blocker (diltiazem) in preventing acoustical trauma during otologic surgery. The patients were randomly divided into a therapy group (diltiazem) and a control group (placebo). Bone conduction hearing thresholds were examined preoperatively and again 1 day and 3 months postoperatively. Frequency-dependent changes in postoperative bone conduction and the number of patients with various degrees of postoperative hearing loss in both groups were statistically analyzed. The results indicated only a small postoperative hearing loss after ear surgery in both groups. …
Abdominal Computed Tomography Angiography at 80kV: feasibility study.
2014
preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV.prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/recons…