Search results for " Nuclear and High Energy Physics."
showing 10 items of 112 documents
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
2017
Abstract The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon–tungsten tracker–converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron–positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m 2 . Silicon planes are interleaved with three layers of tungsten plates, resulting in about o…
In-flight performance of the DAMPE silicon tracker
2018
Abstract DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector , successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy . DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon–Tungsten tracKer–converter (STK), a BGO calorimeter and a neutron detector . The STK is composed of six double layers of single-sided silicon mi…
The Belle II vertex detector integration
2019
Belle II DEPFET, PXD, and SVD Collaborations: et al.
Probing the Merits of Different Event Parameters for the Identification of Light Charged Particles in CHIMERA CsI(Tl Detectors With Digital Pulse Sha…
2013
We investigated the merits of different event parameters in the identification of Light Charged Particles (LCPs) with CsI(Tl) scintillators read out by photodiodes at high incident energy (400 MeV/u). This investigation is made possible by digital signal processing the output signals. As in the conventional analogue case, the digitized signals allow the discrimination of light charged particles by computing the fast and slow components. In addition other identification parameters as the rise time of the output pulses of the CsI(Tl) come out nearly for free. Aim of this paper is the investigation of novel identification plots and the probe of their merits, in particular at relativistic energ…
Evidence for Increased neutron and proton excitations between 51−63 Mn
2015
The hyperfine structures of the odd-even 51−63Mnatoms (N=26 −38) were measured using bunched beam collinear laser spectroscopy at ISOLDE, CERN. The extracted spins and magnetic dipole moments have been compared to large-scale shell-model calculations using different model spaces and effective interactions. In the case of 61,63Mn, the results show the increasing importance of neutron excitations across the N=40subshell closure, and of proton excitations across the Z=28shell gap. These measurements provide the first direct proof that proton and neutron excitations across shell gaps are playing an important role in the ground state wave functions of the neutron-rich Mn isotopes. publisher: Els…
Analysis of spatial diffusion of ferric ions in PVA-GTA gel dosimeters through magnetic resonance imaging
2017
Abstract This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GTA gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an initial steep gradient, were mapped using magnetic resonance imaging on a 7T MRI scanner for small animals. Multiple images of the gels were acquired over several hours after irradiation and were analyzed to quantitatively extract the signal profile. The spatial resolution achieved is 200 μm and this makes this technique particularly suitable for the analysis of steep gradients of ferric ion concentration. The results obtained with PVA-GTA gels were compared with those achieved with agarose gels, which …
An improved limit for Γee of X(3872) and Γee measurement of ψ(3686)
2015
Using the data sets taken at center-of-mass energies above 4 GeV by the BESIII detector at the BEPCII storage ring, we search for the reaction e+eââγISRX(3872)âγISRÏ+ÏâJ/Ï via the Initial State Radiation technique. The production of a resonance with quantum numbers JPC=1++ such as the X(3872) via single photon e+eâ annihilation is forbidden, but is allowed by a next-to-leading order box diagram. We do not observe a significant signal of X(3872) , and therefore give an upper limit for the electronic width times the branching fraction ÎeeX(3872)B(X(3872)âÏ+ÏâJ/Ï)<0.13 eV at the 90% confidence level. This measurement improves upon existing limits by a factor of 46. U…
Analysis of the response of PVA-GTA Fricke-gel dosimeters with clinical magnetic resonance imaging
2018
Abstract Fricke gel dosimeters produced with a matrix of Poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous studies based on spectrophotometry showed valuable dosimetric features of these gels in terms of X-ray sensitivity and diffusion of the ferric ions produced after irradiation. In this study, MRI was performed on the gels at 1.5 T with a clinical scanner in order to optimize the acquisition parameters and obtain high contrast between irradiated and non-irradiated samples. The PVA gels were found to offer good linearity in the range of 0–10 Gy and a stable signal for several hours after irradiation. The sensitivi…
$W^{+}W^{-}$ production at the LHC: fiducial cross sections and distributions in NNLO QCD
2016
We consider QCD radiative corrections to $W^+W^-$ production at the LHC and present the first fully differential predictions for this process at next-to-next-to-leading order (NNLO) in perturbation theory. Our computation consistently includes the leptonic decays of the $W$ bosons, taking into account spin correlations, off-shell effects and non-resonant contributions. Detailed predictions are presented for the different-flavour channel $pp\to\mu^+e^-\nu_\mu {\bar \nu}_e+X$ at $\sqrt{s}=8$ and $13$ TeV. In particular, we discuss fiducial cross sections and distributions in the presence of standard selection cuts used in experimental $W^+W^-$ and $H\to W^+W^-$ analyses at the LHC. The inclus…
Kinematical coincidence method in transfer reactions
2013
A new method to extract high resolution angular distributions from kinematical coincidence measurements in binary reactions is presented. Kinematic is used to extract the center of mass angular distribution from the measured energy spectrum of light particles. Results obtained in the case of 10Be+p-->9Be+d reaction measured with the CHIMERA detector are shown. An angular resolution of few degrees in the center of mass is obtained.