Search results for " Optical Coherence"

showing 10 items of 140 documents

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

2018

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

AdultMaleAgingRefractive errormedicine.medical_specialtyBiometryIntraclass correlationBiomedical Engineering030204 cardiovascular system & hematologyAstigmatismStandard deviationlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineLens thicknessAge groupslawOphthalmologyLens CrystallinemedicineHumansMathematicsKeratometerAge FactorsReproducibility of ResultsGeneral MedicineRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseAxial Length EyeFemaleSurgeryTomography Optical Coherence030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.

2020

To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p  0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …

AdultMaleBiometrygenetic structuresBiometricsComputer scienceAnterior ChamberBiomedical EngineeringHigh resolution030204 cardiovascular system & hematologyEye03 medical and health sciencesYoung Adult0302 clinical medicineOpticsOptical coherence tomographyLens CrystallinemedicineHumansAgedmedicine.diagnostic_testbusiness.industryReproducibility of ResultsPupilGeneral MedicineCoherence (statistics)RepeatabilityMiddle Agedeye diseasesSurgeryFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

2017

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

AdultMaleCorneal PachymetryIntraclass correlationmedicine.medical_treatmentCoefficient of variationBiomedical Engineeringlaw.inventionCorneaYoung Adult03 medical and health sciences0302 clinical medicineOpticslawRefractive surgerymedicineHumansCorneal pachymetryMathematicsKeratometermedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCorneal topographySpherical aberration030221 ophthalmology & optometryFemaleSurgerybusinessTomography Optical Coherence030217 neurology & neurosurgeryBiomedical engineeringExpert Review of Medical Devices
researchProduct

Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…

2016

To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…

AdultMaleDaytimeMaterials sciencegenetic structuresCornea03 medical and health sciences0302 clinical medicineOpticsOptical coherence tomographyCorneamedicineHumansProspective StudiesFourier domainObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryEpithelium CornealReproducibility of ResultsMiddle Agedeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsObserver variationbusiness030217 neurology & neurosurgeryTomography Optical CoherenceBiomedical engineeringCornea
researchProduct

CORRELATION OF OPTICAL COHERENCE TOMOGRAPHY PATTERN AND VISUAL RECOVERY AFTER VITRECTOMY WITH SILICONE OIL FOR RETINAL DETACHMENT

2006

PURPOSE: To assess prospectively the features of the macular surface in silicone oil-filled eyes after surgery by analyzing whether silicone oil affects optical coherence tomography (OCT) measurements and their reproducibility and whether a statistical correlation exists between postoperative best-corrected visual acuity (BCVA) and foveal thickness measured by OCT. METHODS: Twenty eyes of 20 patients underwent vitrectomy with silicone oil tamponade for retinal detachment. After vitrectomy, complete ophthalmic examination including determination of BCVA and OCT was performed to quantify the visual recovery and the foveal thickness. RESULTS: Ophthalmoscopy revealed that the retina appeared to…

AdultMaleFovea Centralismedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentsilicone oilVisual AcuityVitrectomyOphthalmoscopyOptical coherence tomographyVitrectomyOphthalmologyfoveal thicknemedicineHumansSilicone OilsProspective StudiesPostoperative PeriodAgedoptical coherence tomographyFovea Centralimedicine.diagnostic_testbusiness.industryRetinal DetachmentFovea centralisRetinal detachmentRecovery of FunctionGeneral Medicinevisual recoveryMiddle Agedmedicine.diseaseCombined Modality Therapyeye diseasesOphthalmoscopyVitreous BodyProspective StudieOphthalmologymedicine.anatomical_structureVitreous chamberFemalesense organsTamponademedicine.symptombusinessTomography Optical CoherenceHumanRetina
researchProduct

Association of Birth Weight With Foveolar Thickness in Adulthood: Results From a Population-Based Study

2021

Purpose Low birth weight (BW) is associated with alterations of foveal shape development in childhood—leading to an increased retinal thickness of the fovea. The aim of the present study was to assess whether BW has a long-term effect on foveal retinal thickness (RT) and is still present in adulthood. Methods In the German population-based Gutenberg Health Study (GHS), participants were examined with spectral-domain optical coherence tomography. The association between self-reported BW and RT in the foveolar and perifoveal locations was assessed. Multivariable linear regression analyses with adjustment for potential confounders and grading of foveal hypoplasia were performed. Results Overal…

AdultMaleFovea Centralismedicine.medical_specialtyanatomyBirth weightVisual AcuityRetinachemistry.chemical_compoundFovealOphthalmologyHumansMedicinemaculaEye AbnormalitiesProspective StudiesAgedAged 80 and overbusiness.industryConfoundingbirth weightRetinalMiddle Agedmedicine.diseaseConfidence intervalHypoplasiafoveal thicknessLow birth weightFoveolar cellchemistrypopulation-based studyepidemiologyFemalemedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesInvestigative Opthalmology & Visual Science
researchProduct

Evaluation of the anterior chamber angle in keratoconus and normal subjects.

2015

To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…

AdultMaleKeratoconusmedicine.medical_specialtyKeratoconusSensitivity and SpecificityAnterior chamber angleAnterior Eye SegmentReference ValuesOphthalmologymedicineHumansOrbscan iiSlit Lampbusiness.industrySignificant differenceCorneal TopographyReproducibility of ResultsGeneral Medicinemedicine.diseaseControl subjectsOphthalmologyOptometryFemalebusinessTomography Optical CoherenceOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Comparison of Macular Thickness in Patients with Keratoconus and Control Subjects Using the Cirrus HD-OCT

2014

Purpose.The aim of the present study was to compare macular thickness in patients with keratoconus (KC) with macular thickness in healthy subjects.Subjects and Methods.Twenty-six patients with KC and 52 control subjects were included. The macular structure was evaluated using a Zeiss Cirrus HD-OCT. The scan pattern used was 512 × 128, which covers an area of approximately 6 × 6 mm of the retina. The cube volume was assessed as well as macular thickness in each of the 9 sectors defined by the software.Results.The mean signal strength was significantly lower in the KC group (mean 8.4, range 6–10) compared with the control group (mean 9.7, range 7–10),P<0.0001(unpairedt-test). There were no…

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresArticle Subjectlcsh:MedicineKeratoconusAge and sexGeneral Biochemistry Genetics and Molecular BiologySignal strengthOphthalmologyHumansMedicineMacula LuteaIn patientGeneral Immunology and Microbiologybusiness.industrylcsh:RHealthy subjectsGeneral MedicineMiddle AgedControl subjectsmedicine.diseaseeye diseasesCase-Control StudiesOptometryFemaleCirrussense organsbusinessTomography Optical CoherenceResearch ArticleBioMed Research International
researchProduct

Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery

2009

PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityFoveal thicknessMacular EdemaCornea03 medical and health sciencesPostoperative Complications0302 clinical medicineOptical coherence tomographyOphthalmologyBlood-Retinal BarrierHumansMedicineMacula LuteaProspective StudiesIntraoperative ComplicationsAgedAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industrySignificant differenceGeneral MedicinePhacoemulsificationMiddle AgedCataract surgeryeye diseasesOphthalmologySmall incision030221 ophthalmology & optometryFemalesense organsmedicine.symptomCoaxialbusinessTomography Optical Coherence030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct