Search results for " Optics"
showing 10 items of 5880 documents
The identification of vicinally substituted cyclohexane isomers in their mixtures by 1H and 13C NMR spectroscopy.
2000
The radical addition reactions of organobromine compounds, XBr (X = CH2COOMe, PhCH2, CHBr2 and CCl3) with cyclohexene afforded mixtures of cis/trans isomer pairs of 1-X-2-Br-cyclohexanes. In addition to benzyl benzoyloxy derivatives are formed also, when benzoyl peroxide is used as an initiator. Owing to the great difficulties in separating these cis/trans isomer pairs, they are identified directly in their mixtures by NMR spectroscopy. In addition to one-dimensional (ID) 1H, proton decoupled 13C and DEPT-135, also two-dimensional (2D) 13C-13C INADEQUATE as well as 1H-13C HMQC experiments have been used in assigning the signals of each compound in their mixtures. The identification of each …
Adiabatic evolution of quantum-mechanical systems
1991
A description of the adiabatic approximation in terms of the time-evolution operator is presented. Corrections to the approximation are studied, and it is seen that these can be obtained in a simple way in the case of a rapidly oscillating Hamiltonian.
Myopia, the challenge of Ophthalmology and its worldwide “explosive epidemic”
2018
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Noncontact monitoring of vascular lesion phototherapy efficiency by RGB multispectral imaging.
2013
A prototype low-cost RGB imaging system consisting of a commercial RGB CMOS sensor, RGB light-emitting diode ring light illuminator, and a set of polarizers was designed and tested for mapping the skin erythema index, in order to monitor skin recovery after phototherapy of vascular lesions, such as hemangiomas and telangiectasias. The contrast of erythema index (CEI) was proposed as a parameter for quantitative characterization of vascular lesions. Skin recovery was characterized as a decrease of the CEI value relative to the value before the treatment. This approach was clinically validated by examining 31 vascular lesions before and after phototherapy.
The effect of longitudinal chromatic aberration on the lag of accommodation and depth of field.
2016
Purpose Longitudinal chromatic aberration is present in all states of accommodation and may play a role in the accommodation response and the emmetropisation process. We study the change of the depth of field (DOFi) with the state of accommodation, taking into account the longitudinal chromatic aberration. Methods Subjective DOFi was defined as the range of defocus beyond which the blur of the target (one line of optotypes of 0.1 logMAR shown on a black-and-white microdisplay, seen through different colour filters) was perceived as objectionable. The subject's eye was paralysed and different, previously-measured accommodative states (corresponding to the accommodative demands of 0D, 2D and …
Effect of luminance on photopic visual acuity in the presence of laser speckle
1988
Visual acuity in coherent and incoherent light has been determined by using square-wave gratings of 100% contrast. Luminance was varied from 3 to 400 cd/m2. Coherent illumination resulted in a 40% loss of visual acuity. This is probably due to the masking effect of coherent spatial noise (speckle). However, the most interesting finding is the change in shape of the photopic visual-acuity-luminance function. With coherent illumination, the function is vertically displaced and of a different gradient. An increase in luminance produces a decrease in visual acuity. This indicates that the masking effect of the speckle is dependent on luminance. Two observers were used, and similar results were …