Search results for " Optics"

showing 10 items of 5880 documents

Scanning force microscopy based rapid force curve acquisition on supported lipid bilayers: experiments and simulations using pulsed force mode.

2004

In situ pulsed force mode scanning force microscopy (PFM-SFM) images of phase separated solid-supported lipid bilayers are discussed with the help of computer simulations. Simultaneous imaging of material properties and topography in a liquid environment by means of PFM-SFM is severely hampered by hydrodynamic damping of the cantilever. Stiffness and adhesion images of solid-supported membranes consisting of cholesterol, sphingomyelin, and 1,2-dioleyl-phosphatidylcholine obtained in aqueous solution exhibit contrast inversion of adhesion and stiff. ness images depending on parameters such as driving frequency, amplitude, and trigger setting. Simulations using a simple harmonic oscillator mo…

Cantileverbusiness.industryChemistryLipid BilayersPhase (waves)StiffnessSimple harmonic motionMicroscopy Atomic ForceAtomic and Molecular Physics and OpticsSphingomyelinsScanning probe microscopyOpticsCholesterolmedicinePhosphatidylcholinesComputer SimulationPhysical and Theoretical Chemistrymedicine.symptombusinessMaterial propertiesLipid bilayerNon-contact atomic force microscopyChemphyschem : a European journal of chemical physics and physical chemistry
researchProduct

Phase diagram of polymer blends in confined geometry

2001

Within self-consistent field theory we study the phase behavior of a symmetrical binary AB polymer blend confined into a thin film. The film surfaces interact with the monomers via short range potentials. One surface attracts the A component and the corresponding smei-infinite system exhibits a first order wetting transition. The surface interaction of the opposite surface is varied as to study the crossover from capillary condensation for symmetric surfaces fields to the interface localization/delocalization transition for antisymmetric surface fields. In the former case the phase diagram has a single critical point close to the bulk critical point. In the latter case the phase diagram exh…

Capillary waveMaterials scienceCapillary condensationCondensed matter physicsStatistical Mechanics (cond-mat.stat-mech)FOS: Physical sciencesFísicaCondensed Matter - Soft Condensed MatterCondensed Matter PhysicsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsTricritical pointWetting transitionCritical point (thermodynamics)Polymer blendsMaterials ChemistrySoft Condensed Matter (cond-mat.soft)Ising modelPhysical and Theoretical ChemistryCritical exponentConfined geometrySpectroscopyCondensed Matter - Statistical MechanicsPhase diagram
researchProduct

Analysis of Organic Aerosols Using a Micro-Orifice Volatilization Impactor Coupled to an Atmospheric-Pressure Chemical Ionization Mass Spectrometer

2014

We present the development and characterization of a combination of a micro-orifice volatilization impactor (MOVI) and an ion trap mass spectrometer (IT/MS) with an atmospheric-pressure chemical ionization (APCI) source. The MOVI is a multi-jet impactor with 100 nozzles, allowing the collection of aerosol particles by inertial impaction on a deposition plate. The pressure drop behind the nozzles is approximately 5%, resulting in a pressure of 96 kPa on the collection surface for ambient pressures of 101.3 kPa. The cut-point diameter (diameter of 50% collection efficiency) is at 0.13 μm for a sampling flow rate of 10 L min–1. After the collection step, aerosol particles are evaporated by he…

Carboxylic AcidsAnalytical chemistryAtmospheric-pressure chemical ionizationMass spectrometryMass SpectrometryOzoneHumansRelative humiditySpectroscopyBicyclic MonoterpenesAerosolsIonsChemical ionizationChromatographyTerpenesChemistryGeneral MedicineAtomic and Molecular Physics and OpticsAerosolAtmospheric PressureDeposition (aerosol physics)MonoterpenesAerosol mass spectrometryIon trapVolatilizationOxidation-ReductionEuropean Journal of Mass Spectrometry
researchProduct

<title>A portable device for optical assessment of the cardiovascular condition</title>

2003

A hand-held prototype device for detection and processing of the tissue-remitted optical signals has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilation and contraction of skin blood vessels during the cardiac cycle. Cardiovascular condition of the monitored person was assessed by temporal analysis of the recorded PPG signals as well as by shape analysis of the mean single-period PPG signals.© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.

Cardiac cycleTissue opticsbusiness.industryPhotoplethysmogramOptical engineeringeducationMedicinesense organsbusinessBiomedical engineeringSPIE Proceedings
researchProduct

A Robust and Simple Measure for Quality-Guided 2D Phase Unwrapping Algorithms

2016

Quality-based 2D phase unwrapping algorithms provide one of the best tradeoffs between speed and quality of results. Their robustness depends on a quality map, which is used to build a path that visits the most reliable pixels first. Unwrapping then proceeds along this path, delaying unwrapping of noisy and inconsistent areas until the end, so that the unwrapping errors remain local. We propose a novel quality measure that is consistent, technically sound, effective, fast to compute, and immune to the presence of a carrier signal. The new measure combines the benefits of both the quality-guided and the residue-based phase unwrapping approaches. The quality map is justified from the two diff…

Carrier signalPixelbusiness.industryComputer science0211 other engineering and technologiesHolography02 engineering and technology01 natural sciencesComputer Graphics and Computer-Aided DesignPhase unwrappingGeneralLiterature_MISCELLANEOUSlaw.invention010309 opticsInterferometryRobustness (computer science)law0103 physical sciencesComputer visionArtificial intelligencebusinessAlgorithmSoftware021101 geological & geomatics engineeringIEEE Transactions on Image Processing
researchProduct

Nondestructive fluorescence-based quantification of threose-induced collagen cross-linking in bovine articular cartilage.

2012

Extensive collagen cross-linking affects the mechanical competence of articular cartilage: it can make the cartilage stiffer and more brittle. The concentrations of the best known cross-links, pyridinoline and pentosidine, can be accurately determined by destructive high-performance liquid chromatography (HPLC). We explore a nondestructive evaluation of cross-linking by using the intrinsic fluorescence of the intact cartilage. Articular cartilage samples from bovine knee joints were incubated in threose solution for 40 and 100 h to increase the collagen cross-linking. Control samples without threose were also prepared. Excitation-emission matrices at wavelengths of 220 to 950 nm were acquir…

Cartilage Articularmedicine.medical_specialtyCollagen cross linkingBiomedical EngineeringArticular cartilageIn Vitro Techniquesta3111Biomaterialschemistry.chemical_compoundmedicineAnimalsStatistical analysisThreoseCartilagefood and beveragesmusculoskeletal systemFluorescenceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryCross-Linking ReagentsSpectrometry Fluorescencemedicine.anatomical_structurechemistryBiophysicsCattleCollagenTetrosesJournal of biomedical optics
researchProduct

Experimental Study of Central Baffle Flume

2019

In this paper, the hydraulics of a central baffle flume (CBF) were experimentally studied. Extensive experimental runs were carried out to highlight the effects of different geometrical parameters such as baffle length, contraction ratio, and the length of upstream and downstream guide walls. Two different approaches, i.e., the Π theorem of dimensional analysis coupled with the incomplete self-similarity theory and the energy balance equation, were applied to deduce the stage–discharge formula of a CBF characterized by different geometrical parameters. The stage–discharge relationship deduced by the dimensional analysis approach was more accurate than that obtained by the energy approach. F…

Central baffle flumeHydraulicsOptimal design of CBFStage–discharge formula0207 environmental engineeringBaffle02 engineering and technology01 natural sciencesAgricultural and Biological Sciences (miscellaneous)Buckingham’s theoremlaw.invention010309 opticsFlumelaw0103 physical sciencesSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali020701 environmental engineeringIncomplete self-similarityGeologyWater Science and TechnologyCivil and Structural EngineeringMarine engineering
researchProduct

Coprecipitation synthesis of Nd:YAG nanopowders II: the effect of Nd dopant addition the on Luminescence Properties

2009

Abstract Nanopowders of Yttrium Aluminium Garnet (Y3Al5O12, YAG) doped with neodymium (Nd:YAG, 0.2–24.0 at.%) were prepared using the co-precipitation method followed by an annealing treatment up to 950 °C. For a concentration of neodymium lower than 3.2 at.% the materials were found constituted by the garnet phase according to X-ray diffraction investigations. However, at higher neodymium loading the hexagonal and monoclinic forms of yttrium aluminium oxides were found together with the garnet phase. For Nd quantity lower than 0.8% the luminescence emission spectra appear to be nearly the same, indicating that in the examined range of composition the immediate surrounding of the emitting N…

CeramicsMaterials scienceAnnealing (metallurgy)Analytical chemistryNanopowderMineralogychemistry.chemical_elementNeodymiumInorganic Chemistrychemistry.chemical_compoundAluminiumYttrium aluminium garnetElectrical and Electronic EngineeringPhysical and Theoretical ChemistrySpectroscopySettore CHIM/02 - Chimica FisicaDopantOrganic ChemistryLuminescence propertieYttriumNd:YAGAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialschemistryAluminium oxideLuminescence
researchProduct

An Adaptive Combination of Dark and Bright Channel Priors for Single Image Dehazing

2017

Dehazing methods based on prior assumptions derived from statistical image properties fail when these properties do not hold. This is most likely to happen when the scene contains large bright areas, such as snow and sky, due to the ambiguity between the airlight and the depth information. This is the case for the popular dehazing method Dark Channel Prior. In order to improve its performance, the authors propose to combine it with the recent multiscale STRESS, which serves to estimate Bright Channel Prior. Visual and quantitative evaluations show that this method outperforms Dark Channel Prior and competes with the most robust dehazing methods, since it separates bright and dark areas and …

Channel (digital image)business.industryComputer science020206 networking & telecommunications[ INFO.INFO-GR ] Computer Science [cs]/Graphics [cs.GR][ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processingAstrophysics::Cosmology and Extragalactic Astrophysics02 engineering and technologyGeneral Chemistry[INFO.INFO-GR]Computer Science [cs]/Graphics [cs.GR]Atomic and Molecular Physics and OpticsComputer Science ApplicationsElectronic Optical and Magnetic Materials[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]Computer graphics (images)[ INFO.INFO-TI ] Computer Science [cs]/Image ProcessingPrior probability0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processingComputer visionArtificial intelligenceSingle imagebusiness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingJournal of Imaging Science and Technology
researchProduct

Incomplete Charge Collection at Inter-Pixel Gap in Low- and High-Flux Cadmium Zinc Telluride Pixel Detectors.

2022

The success of cadmium zinc telluride (CZT) detectors in room-temperature spectroscopic X-ray imaging is now widely accepted. The most common CZT detectors are characterized by enhanced-charge transport properties of electrons, with mobility-lifetime products μeτe > 10−2 cm2/V and μhτh > 10−5 cm2/V. These materials, typically termed low-flux LF-CZT, are successfully used for thick electron-sensing detectors and in low-flux conditions. Recently, new CZT materials with hole mobility-lifetime product enhancements (μhτh > 10−4 cm2/V and μeτe > 10−3 cm2/V) have been fabricated for high-flux measurements (high-flux HF-CZT detectors).…

Charge-sharing correctionPhotonsPhysics::Instrumentation and DetectorsX-RaysSettore FIS/01 - Fisica SperimentaleAstrophysics::Instrumentation and Methods for AstrophysicsIncomplete charge collectionBiochemistrySemiconductor pixel detectorsAtomic and Molecular Physics and OpticsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CZT detectors; charge sharing; incomplete charge collection; charge-sharing correction; semiconductor pixel detectorsAnalytical ChemistryZincCadmium CompoundsElectrical and Electronic EngineeringCharge sharingTelluriumInstrumentationCZT detectorsCadmiumSensors (Basel, Switzerland)
researchProduct