Search results for " Optics"
showing 10 items of 5880 documents
Review of photoelastic image analysis applied to structural birefringent materials: glass and polymers
2015
Photoelasticity is particularly suitable for the analysis of the stress state in structural materials that are transparent and birefringent. Some techniques of digital photoelasticity (phase shifting and RGB) are applied to the analysis of stress field in two classes of structural materials. The first one consists of tempered glasses, such as those used in the automotive and architectural fields. The second one consists of thermoset polymers, typically used as matrices in fiber reinforced plastic structural composites. The birefringence of such resins is, in particular, exploited to investigate the development of swelling stresses and changes in fracture toughness as induced by water uptake…
Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
2012
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…
Beta-spectrum shapes of forbidden β decays
2018
The neutrinoless [Formula: see text] decay of atomic nuclei continues to attract fervent interest due to its potential to confirm the possible Majorana nature of the neutrino, and thus the nonconservation of the lepton number. At the same time, the direct dark matter experiments are looking for weakly interacting massive particles (WIMPs) through their scattering on nuclei. The neutrino-oscillation experiments on reactor antineutrinos base their analyses on speculations of [Formula: see text]-spectrum shapes of nuclear decays, thus leading to the notorious “reactor antineutrino anomaly.” In all these experimental efforts, one encounters the problem of [Formula: see text]-spectrum shapes of…
Dynamics of Strongly Coupled Modes between Surface Plasmon Polaritons and Photoactive Molecules: The Effect of the Stokes Shift
2017
We have investigated the dynamics of strongly coupled modes of surface plasmon polaritons (SPPs) and fluorescent molecules by analyzing their scattered emission polarization. While the scattered emission of SPPs is purely transverse magnetic (TM) polarized, the strong coupling with molecules induces transverse electric (TE) polarized emission via the partial molecular nature of the formed SPP–molecule polariton mode. We observe that the TM/TE ratio of the polariton emission follows the contribution of the molecular excited states in this hybrid mode. By using several types of molecules, we observe that, in addition to the coupling strength, which determines the contribution of the molecular…
Integration of large-area optical imagers for biometric recognition and touch in displays
2021
In recent years there has been an increasing interest to integrate optical sensing in mobile displays, for instance, for biometric fingerprint scanning functionality. There are several routes to incorporate optical fingerprint functionality within the full display area, each with their own benefits and challenges. Here we investigate the different integration routes using large-area, ultra-thin imagers based on organic photodiodes.
Clinical evaluation of automated capillary refill time estimation in dogs and cats
2019
In this study, we clinically evaluated a pulse oximeter-based device for automated capillary refill time (CRT) estimation in dogs and cats. CRT can reveal conditions like shock or anemia in dogs and cats. However, visual CRT estimation has low repeatability, and the available optical systems for automated estimation are not suitable for pets. We evaluated a custom-made portable CRT measuring device on various measurement sites of 12 dogs and 11 cats with parallel visual CRT estimation on the gum by treating veterinarian. The capillary refill was also recorded by a video camera for reference. The visual and video procedures were moderately correlated with the coefficient of 0.61; visual CRT …
Propulsion Calculated by Force and Displacement of Center of Mass in Treadmill Cross-Country Skiing
2022
This study evaluated two approaches for estimating the total propulsive force on a skier’s center of mass (COM) with double-poling (DP) and V2-skating (V2) skiing techniques. We also assessed the accuracy and the stability of each approach by changing the speed and the incline of the treadmill. A total of 10 cross-country skiers participated in this study. Force measurement bindings, pole force sensors, and an eight-camera Vicon system were used for data collection. The coefficient of multiple correlation (CMC) was calculated to evaluate the similarity between the force curves. Mean absolute force differences between the estimated values and the reference value were computed to evalua…
Origin of the Red Sites and Energy Transfer Rates in Single MEH-PPV Chains at Low Temperature
2011
Single poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) molecules dispersed in thin poly(methylmethacrylate) films have been investigated by fluorescence emission, excitation and time-resolved spectroscopy at 1.2 K. For the molecular weight studied (∼200 kDa) a bimodal distribution of emission maxima is observed. Based on a comparison of the spectroscopic properties of blue and red sites and on polarisation-resolved measurements, we argue in agreement with recent quantum-chemical calculations that the red subpopulation most probably does not arise from interchromophoric excitation delocalisation but is to be attributed to longer chromophoric units originating from orde…
Lifetime measurements of the 3D3/2 and 3D5/2 metastable states in CaII
1993
The lifetime of the metastable 3D3/2 and 3D5/2 states of Ca+ ions is determined in a r.f. ion trap by laser excitation of this levels and subsequent time delayed probing of the state population by a second laser. In a buffer gas atmosphere of about 10−5−10−6 mbar of He we observe quenching to the ground state and strong finestructure mixing of the two D-states. This mixing allowes only the determination of the combined lifetime. Our result of τ(3D)=1.24(39) s is in good agreement with theoretical calculations.
Vibrational population of H 2 + after electroionization of thermal H2
1993
In an ion trap experiment we have determined the vibrational population of the lowest 9 vibrational levels of H2+. We used photodissociation of the trapped molecules by 248 nm light from an excimer laser and the dependence of the photodissociation cross section from the vibrational state. Our results are in good agreement to calculations, which are based on the Franck-Condon principle, but include a variation of the internuclear distance in the transition matrix element.