Search results for " Orthopedic"
showing 10 items of 325 documents
Mid- to Long-Term Outcomes of Cervical Disc Arthroplasty versus Anterior Cervical Discectomy and Fusion for Treatment of Symptomatic Cervical Disc Di…
2015
Purpose This study aimed to investigate the mid- to long-term outcomes of cervical disc arthroplasty (CDA) versus anterior cervical discectomy and fusion (ACDF) for the treatment of 1-level or 2-level symptomatic cervical disc disease. Methods Medline, Embase, and the Cochrane Central Register of Controlled Trials databases were searched to identify relevant randomized controlled trials that reported mid- to long-term outcomes (at least 48 months) of CDA versus ACDF. All data were analyzed by Review Manager 5.3 software. The relative risk (RR) and 95% confidence intervals (CIs) were calculated for dichotomous variables. The weighted mean difference (WMD) and 95%CIs were calculated for conti…
2016
Background Contractile myofibroblasts (MFs) accumulate in the joint capsules of patients suffering from posttraumatic joint stiffness. MF activation is controlled by a complex local network of growth factors and cytokines, ending in the increased production of extracellular matrix components followed by soft tissue contracture. Despite the tremendous growth of knowledge in this field, inconsistencies remain in practice and prevention.
Which route of administration of acid tranexamic, intravenous or intra-articular, is more effective in the control of post-surgical bleeding after a …
2019
Abstract Introduction One of the most frequent complications after a total hip arthroplasty (THA) is bleeding, intravenous tranexamic acid (TXA) is used to reduce it. We considered it necessary to carry out a study to clarify which administration route is superior. Material and method Prospective, controlled and randomized study in 2 arms carried out between February 2017 and February 2018. 15 mg/kg of intravenous TXA were administered in group A and 2 g of intra-articular TXA in group B. The values of haemoglobin and haematocrit were evaluated at 24 h-72 h, blood loss volume, drained blood volume, transfusions and complications. Results 78 patients were included, 31 with intravenous treatm…
Nonunion and malunion in proximal humerus fractures
2020
Proximal humerus fractures are common injuries and the development of nonunion or malunion is infrequent. However, these complications can occur with both operative and non-operative treatment of the fracture. A complete evaluation of these patients must include an investigation of the original fracture, bone and soft tissue quality as well as an extensive radiological study with X-Ray, CT and MRI. Asymptomatic and low demanding patients can benefit from conservative treatment, otherwise surgery is necessary. Multiple treatment options exist with no consensus upon the gold standard. The management of these complications is case-specific and needs extensive pre-operative planning. Arthroscop…
Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion T…
2017
Background Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint. Study Aims We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation. Methods A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups acc…
Movement Variability Increases With Shoulder Pain When Compensatory Strategies of the Upper Body Are Constrained
2017
[DE] This cross-sectional study analyzed the influence of chronic shoulder pain (CSP) on movement variability/kinematics during humeral elevation, with the trunk and elbow motions constrained to avoid compensatory strategies. For this purpose, 37 volunteers with CSP as the injured group (IG) and 58 participants with asymptomatic shoulders as the control group (CG) participated in the study. Maximum humeral elevation (Emax), maximum angular velocity (Velmax), variability of the maximum angle (CVEmax), functional variability (Func_var), and approximate entropy (ApEn) were calculated from the kinematic data. Patients' pain was measured on the visual analogue scale (VAS). Compared with the CG, …
Effects of pregnancy on lumbar motion patterns and muscle responses.
2018
The kinematics of the lumbar region and the activation patterns of the erector spinae muscle have been associated with the genesis of low back pain, which is one of the most common complications associated with pregnancy. Despite the high prevalence of pregnancy-related low back pain, the biomechanical adaptations of the lumbar region during pregnancy remain unknown.This study analyzes lumbar spine motion and the activation pattern of the lumbar erector spinae muscle in healthy pregnant women.A case-control study.The study involved 34 nulliparous women (control group) and 34 pregnant women in the third trimester (week 36 ± 1).We recorded the parameters of angular displacement of the lumbar …
Primary total hip arthroplasty with fourth-generation ceramic bearings: Clinical and survival results with a minimum follow-up of 5 years.
2019
Abstract Objective To evaluate the clinical results and survival of primary hip prosthesis with ceramic delta bearings (C-C) with a minimum follow-up of 5 years. Material and method A total of 205 primary hip arthroplasties performed between 2008 and 2012 were studied. The clinical results, pre-surgical and at 5 years of follow-up were evaluated using the Harris Hip Score (HHS), the Short Form-36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the visual analogue scale (VAS). The position of the prosthetic components, periprosthetic osteolysis, loosening of the prosthetic components and ruptures of the ceramic components were studied radiologically. …
Effect of preoperative flexion contracture in the knee joint on the accuracy of digital templating before knee replacement surgery
2016
Abstract Introduction Flexion contracture in the knee joint before knee replacement surgery has been implicated as one of the factors that could affect the accuracy of digital templating. Aim The aim of the study was to detect the accuracy of digital templating in predicting the size of knee implants and to detect the effect of preoperative flexion contracture in the knee joint on the accuracy of digital templating. Material and methods The flexion contracture of the knee joint was measured in every patient prior to knee replacement surgery and digital templating of the knee joint was made in mediolateral (ML), anteroposterior (AP) and AP long leg views. The sizes of prosthetic components p…
A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
2018
Background Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal. Recently, a locked intraosseous patellar nail prototype was developed. The aim of the present study was to investigate the biomechanical performance of this nail compared with TBW using cannulated screws. Methods Seven paired fresh-frozen human cadaveric knees were stripped of all soft tissues except…