Determination of antimony, arsenic, bismuth and copper by inductively coupled plasma atomic emission spectrometry in the electrorefining of copper

1996

Inductively coupled plasma atomic emissionspectrometry (ICP-AES) has been applied as a rapid and routine method for the analysis of process electrolytes in the electrorefining of copper. Antimony, arsenic, bismuth and copper have been selected as major electrolyte constituents. For these elements profound statistical studies of spectral and interelement effects have been carried out. For As, Bi and Sb two analyte wavelengths have been selected, and for Cu one relatively insensitive analyte line has been chosen due to the high Cu concentration in samples. Best analytical lines were: As at 193.759 nm, Bi at 306.772 nm, Sb at 206.833 nm and Cu at 216.953 nm. Multiple linear regression proved t…

AnalyteAntimonyChemistryAnalytical chemistrychemistry.chemical_elementElectrolyteInductively coupled plasmaBiochemistryCopperArsenicAnalytical ChemistryElectrowinningBismuthAnalytical and Bioanalytical Chemistry
researchProduct

The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…

2009

Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…

AnalyteChromatographyAcoustics and UltrasonicsOrganic ChemistryAnalytical chemistrychemistry.chemical_elementZincInorganic Chemistrychemistry.chemical_compoundChromiumDigestion (alchemy)chemistryFly ashChemical Engineering (miscellaneous)Environmental ChemistryAqua regiaRadiology Nuclear Medicine and imagingInductively coupled plasmaMicrowave digestionUltrasonics sonochemistry
researchProduct

Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…

2010

A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…

AnalyteChromatographyChemistryAnalytical chemistrychemistry.chemical_elementPlasmaAnalytical ChemistryMatrix (chemical analysis)Fly ashStandard additionLinear regressionInductively coupled plasmaSpectroscopyArsenicJournal of Analytical Atomic Spectrometry
researchProduct

First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas

2014

The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…

AnalyteHydrogenAnalytical chemistrychemistry.chemical_elementOxygenAnalytical ChemistryTriple quadrupole mass spectrometerIonAmmoniachemistry.chemical_compoundchemistryIsobaric processInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct

Transmembrane electrochemistry of erythrocytes: Direct electrochemical test for detecting hemolysis in whole blood

2016

A rapid method for detecting hemolysis in whole blood based on a direct electrochemical assay either in venous blood and finger blood, respectively at glassy carbon and screen-printed graphite electrodes is described. The presence of hemolysis is detected from characteristic voltammetric signatures associated to Fe-heme units in healthy and hemolyzed erythrocytes. The voltammetric response of blood was also investigated using scanning electrochemical microscopy (SECM) and scanning tunneling microscopy (STM) and involved transmembrane electrochemistry of erythrocytes superimposed to molecular electrochemistry of heme-containing proteins and heme fragments in the plasma. Voltammetric testing …

Analytical chemistry02 engineering and technologyGlassy carbon010402 general chemistryElectrochemistry01 natural sciencesScanning electrochemical microscopyBlood plasmaMaterials ChemistrymedicineElectrochemistryElectrical and Electronic EngineeringInstrumentationWhole bloodHemolysis indexDetection limitChromatographyChemistryMetals and AlloysVenous blood021001 nanoscience & nanotechnologyCondensed Matter Physicsmedicine.diseaseHemolysis0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsVenous bloodFinger blood0210 nano-technology
researchProduct

Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES)

2008

A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for th…

Analytical chemistryIndiachemistry.chemical_elementFood ContaminationMurrayaToxicologyLimit of DetectionMetals HeavyHumansmedia_common.cataloged_instanceTrace metalEuropean UnionSpicesEuropean unionMicrowavesArseniccomputer.programming_languagemedia_commonChemistrySpectrophotometry AtomicPublic Health Environmental and Occupational HealthTrace elementEnvironmental ExposureCurryDietTrace ElementsInductively coupled plasma atomic emission spectroscopyEnvironmental chemistryInductively coupled plasmacomputerFood ScienceNeutron activationFood Additives and Contaminants: Part B
researchProduct

Optimization of operating conditions of axially and radially viewed plasmas for the determination of trace element concentrations from ultrasound-ass…

2006

Abstract The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 …

Analytical chemistrychemistry.chemical_elementZincPlasmaBiochemistryCopperAnalytical ChemistryMatrix (chemical analysis)chemistryAntimonyInductively coupled plasma atomic emission spectroscopyEnvironmental ChemistryInductively coupled plasmaSpectroscopyArsenicAnalytica Chimica Acta
researchProduct

Polar bosons in one-dimensional disordered optical lattices

2013

We analyze the effects of disorder and quasi-disorder on the ground-state properties of ultra-cold polar bosons in optical lattices. We show that the interplay between disorder and inter-site interactions leads to rich phase diagrams. A uniform disorder leads to a Haldane-insulator phase with finite parity order, whereas the density-wave phase becomes a Bose-glass at very weak disorder. For quasi-disorder, the Haldane insulator connects with a gapped generalized incommesurate density wave without an intermediate critical region.

Anderson localization[PHYS.COND.GAS]Physics [physics]/Condensed Matter [cond-mat]/Quantum Gases [cond-mat.quant-gas]PACS : 67.85.-d 05.30.Jp 61.44.Fw 75.10.PqFOS: Physical sciences01 natural sciencesCondensed Matter::Disordered Systems and Neural NetworksUltracold atoms010305 fluids & plasmasDensity wave theoryCondensed Matter - Strongly Correlated ElectronsUltracold atomQuantum mechanics0103 physical sciencesAnderson localization010306 general physicsBosonPhase diagramPhysicsCondensed Matter::Quantum Gasesdipolar interactionsCondensed matter physicsStrongly Correlated Electrons (cond-mat.str-el)Parity (physics)Disordered Systems and Neural Networks (cond-mat.dis-nn)Condensed Matter - Disordered Systems and Neural NetworksAubry-André transitionCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsQuantum Gases (cond-mat.quant-gas)PolarCondensed Matter::Strongly Correlated ElectronsCondensed Matter - Quantum Gases
researchProduct

Intraoperative cell salvage in ruptured abdominal aortic aneurysms

2010

Aim. The aim of this study was to evaluate the impact of intraoperative cell salvage (ICS) on the early outcome after open repair (OR) of ruptured abdominal aortic aneurysm (rAAA). Methods. This is a retrospective review of 73 consecutive patients who underwent emergency OR of infrarenal rAAA with ICS between 2005 and 2008 (Group I), compared to 51 repairs from 2002-2004 with no ICS (Group II). In addition, a transfusion protocol of platelets and fresh frozen plasma (FFP) administration on admission and during surgery was adopted in patients in Group I to maintain coagulation competence. Results. ICS reduced bank blood demand by 63.6% (from 11 to 4 units, P<0.001) compared to controls, and …

Aneurysm ruptured surgical procedures blood platelets plasma treatment outcomeSettore MED/22 - Chirurgia Vascolare
researchProduct