Search results for " PLASMA"
showing 10 items of 2522 documents
Adiabatic Elimination and Sub-space Evolution of Open Quantum Systems
2020
Efficient descriptions of open quantum systems can be obtained by performing an adiabatic elimination of the fast degrees of freedom and formulating effective operators for the slow degrees of freedom in reduced dimensions. Here, we perform the construction of effective operators in frequency space, and using the final value theorem or alternatively the Keldysh theorem, we provide a correction for the trace of the density matrix which takes into account the non trace-preserving character of the evolution. We illustrate our results with two different systems, ones where the eliminated fast subspace is constituted by a continuous set of states and ones with discrete states. Furthermore, we sh…
Addition of thiourea and hydrochloric acid: Accurate nanogram level analysis of mercury in humic-rich natural waters by inductively coupled plasma ma…
2020
Abstract An analytical method was developed for the direct determination of total mercury in natural waters at low ng L−1 level by inductively coupled plasma mass spectrometry (ICP-MS). The presented method overcomes previously observed problems relating to poor spike recoveries by adding 0.12% thiourea in addition to 3% HCl to all samples and standards. The sample preparation is fast and easy to perform by the developed method since it requires only the addition of HCl and thiourea to the water samples. A very low instrument detection limit (0.4 ng L−1) was obtained without time-consuming preconcentration procedures. The accuracy and precision of the developed method were found excellent b…
Determination of 129I/127I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell
2003
The determination of I-129 in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe-129(+)), possible (IH2+)-I-127 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I-129/I-127 isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope ratio measurements in aqueous solutions and contaminated soil samples directly without sample preparation using ICP-MS with a hexapole collision cell (ICP-CC-QMS) was developed. Oxygen is used as reaction and carrier gas for iodine thermal desorption via the gas phase from solid…
Separation of plutonium and neptunium species by capillary electrophoresis-inductively coupled plasma-mass spectrometry and application to natural gr…
2003
Capillary electrophoresis (CE) was coupled to ICPMS in order to combine the good performance of this separation technique with the high sensitivity of the ICPMS for the analysis of plutonium and neptunium oxidation states. The combination of a fused-silica capillary with a MicroMist AR 30-I-FM02 nebulizer and a Cinnabar small-volume cyclonic spray chamber yielded the best separation results. With this setup, it was possible to separate a model element mixture containing neptunium (NpO2(+)), uranium (UO2(2+)), lanthanum (La3+), and thorium (Th4+) in 1 M acetic acid. The same conditions were also suitable for the separation of various oxidation states of plutonium and neptunium in different a…
Improvement of the detection limit for determination of 129I in sediments by quadrupole inductively coupled plasma mass spectrometer with collision c…
2004
The previously developed sample introduction device for the hot extraction of iodine from environmental samples (soils or sediments) and on-line introduction of analyte via the gas phase in quadrupole inductively coupled plasma mass spectrometry with hexapole collision cell (ICP-CC-QMS) was equipped with a cooling finger, which allowed intermediate iodine enrichment and improved the detection limits for I-129 down to 0.4 pg g(-1) without any additional sample preparation. A mixture of oxygen and helium as reaction gases in the hexapole collision cell was used for reducing the disturbing background intensity of Xe-129(+). Oxygen was also used as the carrier gas for iodine thermal desorption …
A comparative study of flame atomic-absorption methods for determination of zinc in serum and blood plasma
1983
Seven selected methods for determination of zinc in blood plasma by flame atomic-absorption spectroscopy have been compared. Analytical characteristics such as sensitivity, detection limit, precision, analytical recovery, accuracy and physical interferences were studied. Two of the seven methods are recommended as the most suitable for the purpose.
On-line removal of mass interferences in palladium determination by ICP-MS using modified capillaries coupled to micro-flow nebulizers
2001
This paper describes a novel approach developed for on-line removal of interferences within modified capillaries coupled to micro-flow nebulizers, for palladium determination by inductively coupled plasma mass spectrometry (ICP-MS). A strong cation exchanger [2-(4-chlorosulfophenyl)ethyltrichlorosilane)] was covalently bound to the silica capillary that was coupled to a microconcentric nebulizer (MCN) or to a direct injection nebulizer (DIN). The modified surface of the capillary was able to selectively retain copper and yttrium from aqueous samples at pH 7.5 during the sample introduction step, while Pd was not retained and 105Pd could be determined in the absence of interferent elements. …
Determination of uranium in tap water by ICP-MS
2000
A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%…
Determination of ruthenium in photographic emulsions - Development and comparison of different sample treatments and mass spectrometric methods
1999
Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution was used in connection with ICP-MS by external calibration, which has the advantage of a simple sample preparation technique but introduces high amounts of the silver matrix into the mass spectrometer. On the other hand, isotope dilution mass spectrometry (IDMS) with an enriched 99Ru spike solution was applied for ICP-MS and NTI-MS measurements, respectively, in connection with a significant reduc…
Determination of arsenic and antimony in milk by hydride generation atomic fluorescence spectrometry
2002
Abstract A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow m…