Search results for " PUM"
showing 10 items of 412 documents
Comparison of TID response and SEE characterization of single- and multi-level high density NAND flash memories
2009
Heavy ion single-event measurements and total ionizing dose (TID) response for 8Gb commercial NAND flash memories are reported. Radiation results of multilevel flash technology are compared with results from single-level flash technology. The single-level devices are less sensitive to single event upsets (SEUs) than multi-level devices. In general, these commercial high density memories exhibit less TID degradation compared to older generations of flash memories. The charge pump in this study survived up to 600 krads.
The Role of Technology in Participative Processes
2016
Smart city is more and more, in the common feeling, the crossroad of technologies, but first and foremost, the place where humans, contexts and technologies meet and must interact. Technological systems thanks to the deep human interaction acquire an uncertain behaviour that can be hardly modelled and controlled. The resulting complexity, cannot be easily handled with the tools that are available to separate scientific fields. The interdisciplinarity that comes from the implementation of technologies and the dialogue between these and the territories requires new tools for classification and design. New urban design tools are needed allowing to identify in a standardized way adequate suppor…
Novel Wireless Sensor System for Dynamic Characterization of Borehole Heat Exchangers
2011
The design and field test of a novel sensor system based in autonomous wireless sensors to measure the temperature of the heat transfer fluid along a borehole heat exchanger (BHE) is presented. The system, by means of two specials valves, inserts and extracts miniaturized wireless sensors inside the pipes of the borehole, which are carried by the thermal fluid. Each sensor is embedded in a small sphere of just 25 mm diameter and 8 gr weight, containing a transceiver, a microcontroller, a temperature sensor and a power supply. A wireless data processing unit transmits to the sensors the acquisition configuration before the measurements, and also downloads the temperature data measured by the…
Anti-helicobacter regimens
1996
Sobre la presencia de <i>Teucrium pumilum</i> y <i>Teucrium libanitis (Lamiaceae)</i> en la provincia de Valencia
2010
Teucrium pumilum and T. libanitis have been cited from Valencia province (Spain) since the middle of the XXth Century from the gypsic soils in the Valle de Ayora-Cofrentes shire. The analysis of specimens and labels is not conclusive; no specimen would certify the presence of any of these taxa. The field identification and their inclusion in a phyotosociological table ( releve ) by Rivas Goday are the only basis of their presence in the territory in a particular moment of the recent Spanish botanical history. Additionally, the unique herbarium specimen from Valencia, impossible to assign a concrete geographic locality, which was traditionally assigned to T. pumilum by some authors, is actua…
Cellular and tissue expression of DAPIT, a phylogenetically conserved peptide
2011
DAPIT (Diabetes Associated Protein in Insulin-sensitive Tissues) is a small, phylogenetically conserved, 58 amino acid peptide that was previously shown to be down-regulated at mRNA level in insulin-sensitive tissues of type 1 diabetes rats. In this study we characterize a custom made antibody against DAPIT and confirm the mitochondrial presence of DAPIT on cellular level. We also show that DAPIT is localized in lysosomes of HUVEC and HEK 293T cells. In addition, we describe the histological expression of DAPIT in several tissues of rat and man and show that it is highly expressed especially in cells with high aerobic metabolism and epithelial cells related to active transport of nutrients …
Fundamentals of metastability exchange optical pumping in helium
2010
21 pages; International audience; Advances in metastability exchange optical pumping (MEOP) at high laser powers, but also at high gas pressures and high magnetic field strengths, has provided strong motivation for revisiting the understanding of the limitations of this powerful technique. A comprehensive model has been developped for improved description of the combined effects of OP, ME, and relaxation, and of detailed MEOP features observed over the broad range of operating conditions. A brief description is provided, with illustrative comparisons of computed and experimental results. This improved tool is used to explain the excellent photon efficiency of OP obtained at all field streng…
An accurate optical technique for measuring the nuclear polarisation of 3He gas
2010
12 pages; International audience; In the metastability exchange optical pumping cells of our on-site production unit and of our other experimental set-ups, we use a light absorption technique to measure the 3He nuclear polarisation. It involves weak probe beams at 1083 nm, that are either perpendicular or parallel to the magnetic field and cell axis, with suitable light polarisations. When metastability exchange collisions control the populations of the sublevels in the 23S state, absolute values of the 3He ground state nuclear polarisation are directly inferred from the ratio of the absorption rates measured for these probe beams. Our report focuses on the transverse detection scheme for w…
Improving Separation of Oil and Water Using a Novel Coalescing Centrifugal Pump
2017
Abstract A novel centrifugal pump, which increases oil droplet sizes in produced water, has been developed. This paper investigates a concept of pumping pressure optimization with respect to downstream separation efficiency, for the new pump. The investigation shows that the coalescing centrifugal pump always increases the separation efficiency of a downstream hydrocyclone. Furthermore, it is seen that the pumping pressure can be adjusted to maximize the improvement. Experimental results demonstrate how pumping conditions, which minimize the volume fraction of droplets with a diameter smaller than the cut size of the hydrocyclone, maximize the separation efficiency. Finally, it is exemplifi…
Variable Step Size P&O Algorithms for Coalescing Pump/Deoiling Hydrocyclone Produced Water Treatment System
2020
This paper presents three variable step size P&O algorithms for optimizing the separation efficiency of a coalescing pump/deoiling hydrocyclone produced water treatment system. By continuously adjusting the pumping pressure, and subsequently the coalescing effect, the algorithms are used to minimize the oil concentration downstream the hydrocyclone. Due to the variable step size, the algorithms react rapidly to changes in the upstream produced water characteristics, at the same time as they reduce (or eliminate) steady-state oscillations. Based on both simulation and experimental testing, the study discusses advantages and disadvantages of the algorithms.