Search results for " Phase"

showing 10 items of 1862 documents

Determination of ultraviolet filters in bathing waters by stir bar sorptive–dispersive microextraction coupled to thermal desorption–gas chromatograp…

2015

In this work, a new approach that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive solid phase extraction (DSPE), i.e. stir bar sorptive-dispersive microextraction (SBSDµE), is employed as enrichment and clean-up technique for the sensitive determination of eight lipophilic UV filters in water samples. The extraction is accomplished using a neodymium stir bar magnetically coated with oleic acid-coated cobalt ferrite magnetic nanoparticles (MNPs) as sorbent material, which are detached and dispersed into the solution at high stirring rate. When stirring is stopped, MNPs are magnetically retrieved onto the stir bar, which is subjected to thermal desorption (TD) to…

Detection limitSorbentChromatographyTrace AmountsChemistry010401 analytical chemistryExtraction (chemistry)Analytical chemistryThermal desorption02 engineering and technology021001 nanoscience & nanotechnologyMass spectrometry01 natural sciences0104 chemical sciencesAnalytical ChemistrySolid phase extractionGas chromatography–mass spectrometry0210 nano-technologyTalanta
researchProduct

Evaluation of solid-phase extraction and stir-bar sorptive extraction for the determination of fungicide residues at low-microg kg(-1) levels in grap…

2004

Abstract A liquid chromatography–mass spectrometry method has been developed for determining bitertanol, carboxin, flutriafol, pyrimethanil, tebuconazole and triadimefon. The evaluation of both atmospheric pressure interfaces (API), atmospheric pressure chemical ionization (APCI) and electrospray (ESI) using positive and negative ionization modes, clearly shows that the studied pesticides are more sensitive using APCI in positive mode. Two procedures based on solid-phase extraction (SPE) and stir-bar sorptive extraction (SBSE) have been assessed for extracting these compounds in grape. The recoveries obtained by SPE in samples spiked at the limit of quantification (LOQ) level ranged from 60…

Detection limitSpectrometry Mass Electrospray IonizationChromatographyChemistryOrganic ChemistryExtraction (chemistry)Pesticide ResiduesReproducibility of ResultsAtmospheric-pressure chemical ionizationGeneral MedicineHydrogen-Ion ConcentrationMass spectrometryBiochemistryHigh-performance liquid chromatographyGas Chromatography-Mass SpectrometryAnalytical ChemistryFungicides Industrialchemistry.chemical_compoundLiquid chromatography–mass spectrometryPyrimethanilVitisSolid phase extractionAdsorptionMicrowavesChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Analysis of thiabendazole and procymidone in fruits and vegetables by capillary electrophoresis–electrospray mass spectrometry

2002

Abstract A capillary electrophoresis–mass spectrometry method for determining procymidone and thiabendazole in apples, grapes, oranges, pears, strawberries and tomatoes is described. Separation is achieved using a buffer of formic acid–ammonium formate at pH 3.5 with 2% of methanol. Fungicide residues present in the sample are preconcentrated by both solid-phase extraction and injection of large sample volumes into the capillary by a stacking technique, to obtain lower detection limits. Ionization is performed at atmospheric pressure in an electrospray type source and detection is carried out using positive ionization and selected ion monitoring modes. The quantitation limits are 0.005 and …

Detection limitSpectrometry Mass Electrospray IonizationElectrosprayChromatographyOrganic ChemistryPesticide ResiduesElectrophoresis CapillaryGeneral MedicineMass spectrometrySensitivity and SpecificityBiochemistryFungicides IndustrialAnalytical ChemistryBridged Bicyclo Compoundschemistry.chemical_compoundCapillary electrophoresischemistryFruitThiabendazoleVegetablesSample preparationSelected ion monitoringSolid phase extractionProcymidoneJournal of Chromatography A
researchProduct

Identification of the Biotransformation Products of 2-Ethylhexyl 4-(N,N-Dimethylamino)benzoate

2010

Nowadays, 2-ethylhexyl 4-(N,N-dimethylamino)benzoate (EDP) is one of the most widely used UV filters in sunscreen cosmetics and other cosmetic products. However, undesirable processes such as percutaneous absorption and biological activity have been attributed to this compound. The in vitro metabolism of EDP was elucidated in the present work. First of all, the phase I biotransformation was studied in rat liver microsomes and two metabolites, N,N-dimethyl-p-aminobenzoic acid (DMP) and N-monomethyl-p-aminobenzoic acid (MMP), were identified by GC-MS analysis. Secondly, the phase II metabolism was investigated by means of LC-MS. The investigated reactions were acetylation and glucuronidation …

Detection limitSunscreen cosmeticsChromatographyChemistryOriginalMetaboliteOrganic ChemistryClinical BiochemistryGlucuronidation2-Ethylhexyl 4-(NN-dimethylamino)benzoateHigh-performance liquid chromatographyBiochemistryAnalytical Chemistrychemistry.chemical_compoundBiotransformationLiquid chromatography–mass spectrometryMicrosomeSolid phase extractionLiquid chromatography-mass spectrometryUV filtering
researchProduct

Simple and sensitive reversed-phase liquid chromatographic assay for analysis of chlorthalidone in urine

1993

Abstract This study describes a rapid method for the determination of chlorthalidone in human urine by reversed-phase liquid chromatography and UV detection at 230 nm, after clean-up over a C8 solid-phase extraction column. Liquid chromatography was carried out on a C18-bonded phase using acetonitrile-phosphate buffer (pH=3) gradient elution. Triamterene was used as internal standard. The system has been applied to the determination of chlorthalidone in the 0.10–10.0 μg/mL concentration interval; the limit of detection was 6 ng/mL.

Detection limitTriamtereneChromatographyChemistryExtraction (chemistry)medicineMolecular MedicineChlorthalidoneSolid phase extractionReversed-phase chromatographyHigh-performance liquid chromatographyQuantitative analysis (chemistry)medicine.drug
researchProduct

Comparison of different sorbents for on-line liquid-solid extraction followed by high-performance liquid chromatographic determination of nitrogen-co…

1998

Abstract LiChrolut EN [poly(styrene-divinylbenzene), PSDVB], Carbograph (graphitized carbon black, GCB), Isolute CN (cyanopropylsilica), Isolute C 2 (ethylsilica), and LiChrospher RP18 (octadecylsilica) were studied for on-line solid-phase extraction of twelve nitrogen containing pesticides from water. Determination (UV 210 nm) was performed with a Spherisorb C 8 analytical column and an acetonitrile-water gradient. The mean recoveries from 50 ml ranged from 83% for RP18 to 44% for GCB, and decreased in the following order: RP18, CN, LiChrolut EN, C 2 , and GCB. GCB showed poor recoveries due to incomplete desorption with the acetonitrile-water gradient used, and memory effects were detecte…

Detection limitVinyl CompoundsChromatographyNitrogenChemistryElutionOrganic ChemistryExtraction (chemistry)General MedicineReversed-phase chromatographySilicon DioxideBiochemistryHigh-performance liquid chromatographyBackflush accountingCarbonAnalytical ChemistryPolystyrenesIndicators and ReagentsSpectrophotometry UltravioletSample preparationSolid phase extractionPesticidesChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Bio-metal-organic frameworks for molecular recognition and sorbent extraction of hydrophilic vitamins followed by their determination using HPLC-UV

2020

A bio-metal-organic framework (bio-MOF) derived from the amino acid L-serine has been prepared in bulk form and evaluated as sorbent for the molecular recognition and extraction of B-vitamins. The functional pores of bio-MOF exhibit high amounts of hydroxyl groups jointly directing other supramolecular host-guest interactions thus providing the recognition of B-vitamins in fruit juices and energy drinks. Single-crystal X-ray diffraction studies reveal the specific B-vitamin binding sites and the existence of multiple hydrogen bonds between these target molecules and the framework. It offered unique snapshots to accomplish an efficient capture of these solutes in complex aqueous matrices. Fo…

Detection limitVitaminesSorbentChromatographySurface PropertiesUltraviolet RaysElutionChemistryHydrophilic interaction chromatography010401 analytical chemistryExtraction (chemistry)Supramolecular chemistryQuímica analítica010402 general chemistry01 natural sciences0104 chemical sciencesAnalytical ChemistryBegudesMolecular recognitionVitamin B ComplexAdsorptionSolid phase extractionParticle SizeHydrophobic and Hydrophilic InteractionsMetal-Organic FrameworksMicrochimica Acta
researchProduct

Vapor-phase introduction of alkyltin compounds in atomic absorption spectrophotometry

1990

Abstract Different systems for the introduction of alkyltin compounds in atomic absorption spectrophotometry using the vapor-phase introduction approach have been compared. Samples and standards were introduced in both quartz cell and flame atomizer using a vertical and a horizontal reactor. The better sensitivity was obtained with the quartz cell and the horizontal reactor.

Detection limitVolatilisationlawChemistryVapor phaseAnalytical chemistryTrace analysisAtomic absorption spectroscopyQuartzSpectroscopyAnalytical Chemistrylaw.inventionMicrochemical Journal
researchProduct

Online Solid-Phase Extraction LC-MS/MS: A Rapid and Valid Method for the Determination of Perfluorinated Compounds at Sub ng·L-1Level in Natural Water

2018

In this research paper, we report a method able to detect perfluorinated compound at pg·L−1 levels in superficial and underground water samples. An online solid phase extraction HPLC-MS/MS method was developed for the analysis of 12 perfluoroalkyl acids (PFASs). The method is based on injection of 5000 µL of water sample in SPE online WAX column followed by chromatography separation and mass spectrometry determination. SPE online elution was performed by water + 0.05% NH4OH and methanol + 0.05% NH4OH, while separation of target compounds was achieved within 10 min by Gemini chromatographic column operating from 1 to 12 pH range and using a mixture of water-methanol + 0.05% NH4OH. Sub ng·L−1…

Detection limitWaxChromatographyArticle SubjectElution010401 analytical chemistryChemistry (all)Perfluorinated compoundGeneral Chemistry010501 environmental sciencesMass spectrometry01 natural sciences0104 chemical scienceslcsh:Chemistrychemistry.chemical_compoundchemistrylcsh:QD1-999visual_artLc ms msvisual_art.visual_art_mediumSolid phase extractionQuantitative analysis (chemistry)0105 earth and related environmental sciences
researchProduct

Determination of carbonyl compounds in particulate matter PM2.5 by in-tube solid-phase microextraction coupled to capillary liquid chromatography/mas…

2013

Abstract In this paper, a new procedure based on in-tube solid phase microextraction (IT-SPME)-capillary liquid chromatography hyphenated to mass spectrometry detection by using microelectrospray ionisation (CapLC–MS), has been reported. The device was proposed to quantify 12 carbonyl compounds (10 aliphatic aldehydes, an unsaturated aldehyde and a ketone) derivatized with 2,4-dinitrophenylhidrazine (DNPH) reagent in aqueous extracts of PM 2.5 . This methodology involves the on-line preconcentration of DNPH-carbonyl compounds derivatives coupled to the CapLC–MS system, efficiently providing appropriate sensitivity for the determination of the target analytes. Detection limits for the analyt…

Detection limitchemistry.chemical_classificationAnalyteAldehydesChromatographyKetoneAnalytical chemistryKetonesMass spectrometrySolid-phase microextractionAldehydeMass SpectrometryAnalytical ChemistryPhenylhydrazineschemistryLiquid chromatography–mass spectrometryLimit of DetectionReagentParticulate MatterSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidTalanta
researchProduct