Search results for " Prosthesis"

showing 10 items of 441 documents

In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents

2005

Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentDental CementsDentistryCrown (dentistry)Dental Prosthesis RetentionDental porcelainstomatognathic systemDental cementMaterials TestingmedicineHumansCeramicComposite materialCementationCementUniversal testing machineCrownsCompomersbusiness.industryLuting agentEpoxyDental PorcelainResin CementsGlass Ionomer Cementsvisual_artvisual_art.visual_art_mediumZirconiumOral SurgerybusinessThe Journal of Prosthetic Dentistry
researchProduct

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.

2009

Summary  Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…

Dental Stress Analysisinfluence of post-materialMaterials sciencemedicine.medical_treatmentGlass fiberFinite Element AnalysisDentistryCrown (dentistry)Dental Materialsstomatognathic systemFlexural strengthstress distributionMaterials TestingmedicineMaxillaHumansMaxillary central incisorDental Restoration PermanentGeneral Dentistryinfluence of post-diameterbusiness.industrybiomechanical performanceStress distributionIncisorstomatognathic diseasesDental Prosthesis DesignFracture (geology)pre-fabricated intra-radicular postsinfluence of crownFinite element techniqueGlassbusinessPost and Core TechniqueJournal of oral rehabilitation
researchProduct

A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…

2020

Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…

Dental softwarebusiness.industryComputer scienceMouth RehabilitationIntervention approachDentistryCAD030206 dentistryComposite ResinsDental Porcelain03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental Prosthesis DesignVirtual imageTooth wearDental Prosthesis DesignComputer-Aided DesignHumansTooth WearOral SurgeryMouth RehabilitationbusinessThe Journal of prosthetic dentistry
researchProduct

Digitalization ih prosthesis innovative methodology on a clinical case

2019

Digitalization prosthesis innovative methodology
researchProduct

Stent oversizing or not-oversizing? An unresolved dilemma

2021

Primary PCI plus stent implantation is indicated for treatment of acute coronary syndrome. Technically, due to the difference in lumen diameter between vessel portions and stent size in some coronary arteries, post-expansion of the stent is usually necessary to match proximal reference diameter and optimize stent apposition. Incomplete stent apposition has been associated with increased risk of in stent restenosis (ISR) and stent thrombosis (1) despite new stent technologies have largely reduced this risk (2-3). Although new antiplatelet drugs showed a more rapid onset of action and a stronger effect (4-5), stent apposition remains an important risk factor for stent thrombosis. As stent pos…

Dilemmamedicine.medical_specialtybusiness.industrymedicine.medical_treatmentmedicineMEDLINEStentStentsbusinessstent PCICardiology and Cardiovascular MedicineBlood Vessel ProsthesisSurgeryMinerva Cardiology and Angiology
researchProduct

Ten-Year Retrospective Follow-Up Study of the TiOblast™ Dental Implant

2010

Purpose: Long-term results in the clinical outcome of different implant systems, including high patient numbers and a long follow-up time, are rare. This retrospective study evaluated the cumulative survival rate of a self-tapping, cylindrical implant system with a conical implant-abutment connection after 10 years of prosthetic loading. Materials and Methods: A total of 516 TiOblast™ implants (Astra Tech AB, Molndal, Sweden) were placed in 108 patients. The patients were treated in the Department of Oral and Maxillofacial Surgery, Johannes Gutenberg University, Mainz, Germany, between September 1994 and May 2005. The main indications for implantation were the treatment of edentulous mandib…

Edentulismmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentDental prosthesisDentistryRetrospective cohort studymedicine.diseaseOsseointegrationSurgeryDental Implant-Abutment DesignmedicineOral and maxillofacial surgeryImplantOral SurgerybusinessDental implantGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Multi-objective optimization of nitinol stent design.

2017

Nitinol stents continuously experience loadings due to pulsatile pressure, thus a given stent design should possess an adequate fatigue strength and, at the same time, it should guarantee a sufficient vessel scaffolding. The present study proposes an optimization framework aiming at increasing the fatigue life reducing the maximum strut strain along the structure through a local modification of the strut profile.The adopted computational framework relies on nonlinear structural finite element analysis combined with a Multi Objective Genetic Algorithm, based on Kriging response surfaces. In particular, such an approach is used to investigate the design optimization of planar stent cell.The r…

EngineeringCompressive Strengthmedicine.medical_treatment02 engineering and technology030204 cardiovascular system & hematologycomputer.software_genreMulti-objective optimization0302 clinical medicineStentComputer Aided DesignFatigueSafety factorStructural engineeringEquipment DesignFatigue limitFinite element methodsurgical procedures operativeComputer-Aided DesignStentsAlgorithms0206 medical engineeringFinite Element AnalysisBiophysicsBiomedical EngineeringFatigue; Multi-objective optimization; Nitinol; Stent; Structural finite element analysis; Tapered strut; Biophysics; Biomedical Engineering03 medical and health sciencesBlood vessel prosthesisElastic ModulusTensile StrengthGenetic algorithmmedicineAlloysPressureComputer Simulationcardiovascular diseasesbusiness.industryStentStructural finite element analysiNitinolModels Theoreticalequipment and supplies020601 biomedical engineeringTapered strutBlood Vessel ProsthesisMulti-objective optimizationEquipment Failure AnalysisBiophysicStress MechanicalbusinesscomputerMedical engineeringphysics
researchProduct

An implant-supported overdenture design with a horizontal path of insertion

2013

The rehabilitation of the atrophic maxilla by means of implant-supported prostheses cannot always be achieved with fixed prostheses because of anatomic, esthetic, or economic issues, so for some patients the treatment of choice is a removable prosthesis. This article analyzes a new design for implant-supported overdentures with horizontal or faciolingual insertion. Its retention system is based on frictional forces or stepped interlocking horizontal surfaces and is appropriate for patients with skeletal Class II or III relationships with severe maxillary atrophies. The design facilitates implant-prosthetic hygiene and improved esthetics in patients with nonparallel implants by hiding abutme…

EngineeringFrictionDentistryEsthetics DentalMalocclusion Angle Class IIMaxillaAtrophic maxillaHumansIn patientDenture DesignInterlockingbusiness.industryDenture Complete UpperDental Implant-Abutment DesignDenture OverlayOral HygieneSkeletal classDenture RetentionMalocclusion Angle Class IIIRemovable prosthesisDental Prosthesis Implant-SupportedAtrophyOral SurgerybusinessAbutment (dentistry)Implant supportedThe Journal of Prosthetic Dentistry
researchProduct

Bioengineered vascular scaffolds: the state of the art

2014

To date, there is increasing clinical need for vascular substitutes due to accidents, malformations, and ischemic diseases. Over the years, many approaches have been developed to solve this problem, starting from autologous native vessels to artificial vascular grafts; unfortunately, none of these have provided the perfect vascular substitute. All have been burdened by various complications, including infection, thrombogenicity, calcification, foreign body reaction, lack of growth potential, late stenosis and occlusion from intimal hyperplasia, and pseudoaneurysm formation. In the last few years, vascular tissue engineering has emerged as one of the most promising approaches for producing …

EngineeringIntimal hyperplasiaBiomedical EngineeringMedicine (miscellaneous)ThrombogenicityNew materialsBioengineeringBiocompatible MaterialsVascular graftBiomaterialsTissue engineeringBlood vessel prosthesisBiomaterials; Tissue engineering; Vascular grafts; Vascular prosthesesmedicineHumansTissue engineeringTissue Scaffoldsbusiness.industrySettore ING-IND/34 - Bioingegneria IndustrialeGeneral Medicinemedicine.diseaseBiocompatible materialBiomaterialBlood Vessel ProsthesisStenosisSettore MED/18 - Chirurgia GeneraleVascular tissue engineeringVascular prosthesesbusinessBiomedical engineering
researchProduct