Search results for " Prosthesis"
showing 10 items of 441 documents
In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents
2005
Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…
Premolars restored with posts of different materials: fatigue analysis
2011
Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…
Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.
2009
Summary Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…
A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…
2020
Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…
Digitalization ih prosthesis innovative methodology on a clinical case
2019
Stent oversizing or not-oversizing? An unresolved dilemma
2021
Primary PCI plus stent implantation is indicated for treatment of acute coronary syndrome. Technically, due to the difference in lumen diameter between vessel portions and stent size in some coronary arteries, post-expansion of the stent is usually necessary to match proximal reference diameter and optimize stent apposition. Incomplete stent apposition has been associated with increased risk of in stent restenosis (ISR) and stent thrombosis (1) despite new stent technologies have largely reduced this risk (2-3). Although new antiplatelet drugs showed a more rapid onset of action and a stronger effect (4-5), stent apposition remains an important risk factor for stent thrombosis. As stent pos…
Ten-Year Retrospective Follow-Up Study of the TiOblast™ Dental Implant
2010
Purpose: Long-term results in the clinical outcome of different implant systems, including high patient numbers and a long follow-up time, are rare. This retrospective study evaluated the cumulative survival rate of a self-tapping, cylindrical implant system with a conical implant-abutment connection after 10 years of prosthetic loading. Materials and Methods: A total of 516 TiOblast™ implants (Astra Tech AB, Molndal, Sweden) were placed in 108 patients. The patients were treated in the Department of Oral and Maxillofacial Surgery, Johannes Gutenberg University, Mainz, Germany, between September 1994 and May 2005. The main indications for implantation were the treatment of edentulous mandib…
Multi-objective optimization of nitinol stent design.
2017
Nitinol stents continuously experience loadings due to pulsatile pressure, thus a given stent design should possess an adequate fatigue strength and, at the same time, it should guarantee a sufficient vessel scaffolding. The present study proposes an optimization framework aiming at increasing the fatigue life reducing the maximum strut strain along the structure through a local modification of the strut profile.The adopted computational framework relies on nonlinear structural finite element analysis combined with a Multi Objective Genetic Algorithm, based on Kriging response surfaces. In particular, such an approach is used to investigate the design optimization of planar stent cell.The r…
An implant-supported overdenture design with a horizontal path of insertion
2013
The rehabilitation of the atrophic maxilla by means of implant-supported prostheses cannot always be achieved with fixed prostheses because of anatomic, esthetic, or economic issues, so for some patients the treatment of choice is a removable prosthesis. This article analyzes a new design for implant-supported overdentures with horizontal or faciolingual insertion. Its retention system is based on frictional forces or stepped interlocking horizontal surfaces and is appropriate for patients with skeletal Class II or III relationships with severe maxillary atrophies. The design facilitates implant-prosthetic hygiene and improved esthetics in patients with nonparallel implants by hiding abutme…
Bioengineered vascular scaffolds: the state of the art
2014
To date, there is increasing clinical need for vascular substitutes due to accidents, malformations, and ischemic diseases. Over the years, many approaches have been developed to solve this problem, starting from autologous native vessels to artificial vascular grafts; unfortunately, none of these have provided the perfect vascular substitute. All have been burdened by various complications, including infection, thrombogenicity, calcification, foreign body reaction, lack of growth potential, late stenosis and occlusion from intimal hyperplasia, and pseudoaneurysm formation. In the last few years, vascular tissue engineering has emerged as one of the most promising approaches for producing …