Search results for " Prosthesis"

showing 10 items of 441 documents

The influence of lateral release on patello-femoral joint loading in knee arthroplasty

1992

Eight fresh, cadaveric knees have been fitted with four different total knee cemented prostheses. Loading forces at the bone implant fixation interface of the patella component have been measured in a knee joint testing rig by four miniaturized force transducers, before and after a lateral release of the patellar retinaculum. The lateral release resulted in a significant local force reduction in the lateral and/or proximal quadrant of the patella resection plane depending on the knee flexion angle, quadriceps tensile force direction, and the patellar prosthesis design.

musculoskeletal diseasesKnee Jointmedicine.medical_treatmentTransducersIn Vitro TechniquesKnee JointProsthesis DesignProsthesisWeight-BearingCadaverHumansMedicineOrthopedics and Sports MedicineFixation (histology)OrthodonticsLateral releasebusiness.industryPatellamusculoskeletal systemArthroplastyLigaments ArticularSurgeryPatellaKnee ProsthesisbusinessCadaveric spasmhuman activitiesInternational Orthopaedics
researchProduct

Cementless acetabular reconstruction and structural bone-grafting in dysplastic hips. Surgical technique.

2007

BACKGROUND: Studies of acetabular reconstruction with use of cement and bulk bone graft have demonstrated increasing rates of cup failure in patients with dysplastic hips seven years after total hip arthroplasty. Comparable data on the long-term results of bulk bone-grafting done in conjunction with cementless implants are limited. The aim of this study was to review the clinical and radiographic results of autologous bulk bone-grafting in conjunction with a cementless cup. METHODS: From 1987 to 1992, forty-seven patients (forty women and seven men, with an average age of 50.4 years) who had developmental dysplasia of the hip underwent fifty-six total hip arthroplasties and received a struc…

musculoskeletal diseasesMaleReoperationmedicine.medical_specialtyRadiographymedicine.medical_treatmentBone graftingTransplantation AutologousArthroplastymedicineHip DislocationHumansOrthopedics and Sports MedicineProspective StudiesSurvival rateHip dysplasiaBone Transplantationbusiness.industryAcetabulumGeneral MedicineMiddle Agedmedicine.diseaseAcetabulumSurgeryProsthesis FailureTransplantationRadiographysurgical procedures operativeTreatment OutcomeOrthopedic surgerySurgeryFemaleImplantHip ProsthesisbusinessThe Journal of bone and joint surgery. American volume
researchProduct

Biomechanical Analysis of a New Elbow Prosthesis

2019

Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…

musculoskeletal diseasesTotal elbow arthroplasty FEM Reverse engineering CADFEM030222 orthopedicsbusiness.industryElbowAseptic looseningDentistry030229 sport sciencesmusculoskeletal systemElbow prosthesisTotal elbow arthroplasty03 medical and health sciences0302 clinical medicinemedicine.anatomical_structuremedicineTotal elbow arthroplastyCADImplantSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineeringbusiness
researchProduct

Optimal positioning of the humeral component in the reverse shoulder prosthesis.

2014

Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…

musculoskeletal diseasesmedicine.medical_specialtyFEM analysesmedicine.medical_treatmentReplacementDeltoid curveProsthesis DesignProsthesisArthroplastyArthropathymedicineHumansOrthopedics and Sports MedicineHumerusRotator cuffArthroplasty ReplacementSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeTotal reverse shoulder arthroplasty Intrinsic stability FEM analyses Polyethylene wear Stability ratioFEM analyses; Intrinsic stability; Polyethylene wear; Stability ratio; Total reverse shoulder arthroplasty; Arthroplasty Replacement; Humans; Humerus; Prosthesis Design; Shoulder Joint; Orthopedics and Sports Medicine; Surgery; Medicine (all)business.industryShoulder JointMedicine (all)Intrinsic stabilityHumerusShoulder Prosthesismedicine.diseaseArthroplastySurgerymedicine.anatomical_structurePolyethylene wearStability ratioTotal reverse shoulder arthroplastySurgeryShoulder jointbusinesshuman activitiesMusculoskeletal surgery
researchProduct

Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences

2020

Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…

musculoskeletal diseasesmedicine.medical_specialtyKinematicsKnee Jointmedicine.medical_treatmentComparisonKinematicsPromProsthesis DesignProsthesis03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicinePosterior-stabilized kneeRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeArthroplasty Replacement KneeOrthodontics030222 orthopedicsKnee laxitybusiness.industryTKAPosterior stabilized030229 sport sciencesKinematicmusculoskeletal systemNavigationBiomechanical PhenomenaSurgeryCohortOrthopedic surgerySurgeryMobile bearingKnee ProsthesisRange of motionbusinessMUSCULOSKELETAL SURGERY
researchProduct

Patient Specific Instrumentation for Total Knee Arthroplasty: a Literature Review

2014

During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient’s knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instru…

musculoskeletal diseasesmedicine.medical_specialtyKnee JointTotal knee arthroplastytotal knee arthroplasty patient specific instrumentation PSI knee ProsthesisSettore MED/33 - Malattie Apparato LocomotoreMedicineHumansOrthopedics and Sports MedicineComponent alignmentInstrumentation (computer programming)Arthroplasty Replacement KneeEvidence-Based Medicinebusiness.industryMagnetic Resonance ImagingSurgeryTreatment OutcomePatient specific instrumentationSurgery Computer-AssistedOrthopedic surgeryPractice Guidelines as TopicPhysical therapySurgerybusinessKnee ProsthesisTomography X-Ray Computed
researchProduct

The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement

1992

Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.

musculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatmentKnee replacementDentistryIn Vitro TechniquesKnee JointProsthesis Designmedicine.disease_causeCondyleWeight-bearingWeight-BearingMotionCadavermedicineHumansOrthopedics and Sports MedicineFemurOrthodonticsbusiness.industryBone Cementsequipment and suppliesmusculoskeletal systemSagittal planesurgical procedures operativemedicine.anatomical_structureOrthopedic surgerySurgeryKnee ProsthesisbusinessCadaveric spasmInternational Orthopaedics
researchProduct

Appropriateness of surgery performed for abdominal aortic aneurysm at tertiary hospitals in Spain

2021

Background: The aim of this study was to analyze the appropriateness of the type of repair (open or endovascular) performed for abdominal aortic aneurysm (AAA) in five university hospitals in Spain, according to evidence-based recommendations. Methods: A multicenter, retrospective cross-sectional study of patients with AAA who underwent elective open surgical repair (OSR) or endovascular aneurysm repair (EVAR). Data were collected on demographic and clinical variables and type of surgical repair. A pair of vascular surgeons from each participating hospital performed a blinded assessment based on GRADE recommendations. The concordance between the two evaluators and the agreement between thei…

operativemedicine.medical_specialtyConcordancemedicine.medical_treatmentPatient characteristicsEndovascular aneurysm repairTertiary Care CentersBlood Vessel Prosthesis ImplantationSurgical proceduresAbdomenHumansMedicineAgedRetrospective StudiesSurgical repairAortic aneurysmbusiness.industryEndovascular Proceduresmedicine.diseaseUniversity hospitalAneurysmPatient preferenceAbdominal aortic aneurysmSurgeryCross-Sectional StudiesTreatment OutcomeElective Surgical ProceduresSpainCharlson comorbidity indexabdominalCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalInternational Angiology
researchProduct

Painful prosthesis: approaching the patient with persistent pain following total hip and knee arthroplasty.

2013

BACKGROUND: Symptomatic severe osteoarthritis and hip osteoporotic fractures are the main conditions requiring total hip arthroplasty (THA), whereas total knee arthroplasty (TKA) is mainly performed for pain, disability or deformity due to osteoarthritis. After surgery, some patients suffer from "painful prosthesis", which currently represents a clinical problem. METHODS: A systematic review of scientific literature has been performed. A panel of experts has examined the issue of persistent pain following total hip or knee arthroplasty, in order to characterize etiopathological mechanisms and define how to cope with this condition. RESULTS: Four major categories (non infective, septic, othe…

painful prosthesispersistent painSettore MED/33 - Malattie Apparato LocomotoreMini-Reviewknee arthroplastyhip arthroplasty
researchProduct

Periodontal Behavior Around Teeth Prepared with Finishing Line for Restoration with Fixed Prostheses. A Systematic Review and Meta-Analysis

2020

Background: The objective of this systematic review and meta-analysis was to analyze the periodontal behavior around teeth prepared with horizontal finishing crowns supporting fixed metal-ceramic and zirconia full coverage crowns and fixed partial dentures (FDPs). Materials and methods: An electronic search was conducted to locate relevant clinical trials in four databases: PubMed, Embase, Cochrane, and Scopus. A manual search was made in the reference sections of the articles identified for any additional articles. No restrictions were applied regarding year of publication or language. The following variables were considered in quantitative and qualitative analysis: probing pocket depth (P…

periodontal prosthesisBleeding on probingDentistrylcsh:MedicineReviewPlaque controlPeriodontal Prosthesis03 medical and health sciences0302 clinical medicineQualitative analysisstomatognathic systemUntreated controlzirconium oxideMedicinebiological factorbusiness.industryDental prosthesislcsh:Rdental prosthesis030206 dentistryGeneral Medicinestomatognathic diseases030220 oncology & carcinogenesisMeta-analysismedicine.symptombusinessGingival marginmetal ceramic restorationsJournal of Clinical Medicine
researchProduct