Search results for " Protection."
showing 10 items of 925 documents
Investigating the effect of distributed generators on traditional protection in radial distribution systems
2013
The recent changes in power network structure, development in green energy technologies and increased attention on environmental concerns have led to increase the installation of renewable energy based distributed generations (DG) in distribution networks. The increasing penetration of distributed generation in the distribution power system creates new technical and economical challenges; protection is one important topic of these challenges. High penetration of DG will have unfavorable impact on the traditional protection methods; the impact depends on the number, location and size of injected DG. To ensure safe and selective protection devices coordination, the impact of DG should be take…
Passive-damping design for vibration control of large structures
2013
In this work, a systematic strategy to design passive damping systems for structural vibration control is presented. The proposed design methodology is based on the equivalence between decentralized static velocity-feedback controllers and passive damping systems. By using recent developments in static output-feedback control, the design of passivedamping systems can be formulated as a single optimization problem with Linear Matrix Inequality constraints. Moreover, this optimization problem can be efficiently solved with standard numerical tools, even for large dimension systems. Due to its computational effectiveness, the proposed methodology can be applied to the design of passive damping…
Renewable energy sources to fulfill the global energy needs of a country: The case study of Malta in Mediterranean Sea
2016
The paper shows the advantages using different energy resources for the islands of Malta. Moreover, this work is focused on the analysis of the wave energy potential along Malta's coasts. This important resource can be exploited to produce electrical energy using an innovative Point Absorber based on a new generator prototype realized by University of Palermo. The use of renewable source will reduce greenhouses emissions and increase the energy independence of Malta. The procedures applied in the present article, as well as the main equations used, are the result of previous applications made in different technical fields that show a good replicability [1]-[7].
Experimental evaluation of an hybrid communication system architecture for smart grid applications
2015
In this paper a new communication system architecture is proposed for the development of a SCADA system which can remotely monitor and control intelligent electronic devices (IEDs) connected to the low voltage distribution networks, i.e low voltage smart meter (SM), interface protection devises (IPS). New distributed metering systems and interface devices, together with a proper communication infrastructure (HiperLAN and narrowband power line communication (NB-PLC) on low voltage network), have been developed to allow monitoring the whole power system and controlling the distributed generators of a Smart Grid also in the presence of harmonic distortions. In this way, the electrical energy d…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
USEDAT: USA-Europe Data Analysis Training Worldwide Program, 2019 ed.
2019
USA-Europe Data Analysis Training School (USEDAT) is a Multi-center Trans-Atlantic initiative offering hands-on training focused in both Introduction to Experimental Data Recording (NMR, MS, IR, 2DGE, EEG, etc.) and/or posterior Computational Data Analysis (Machine Learning, Complex Networks, etc.). We made emphasis on applications in for Cheminformatics, Bioinformatics, Medicinal Chemistry, Nanotechnology, Systems Biology, Biomedical Engineering, etc. The school also promotes training and knowledge of ethical and legal regulatory issues (GDPR, REACH, OECD, FDA, etc.) about data use and data protection in chemistry and biomedical research. The school is directed to researchers and students …
Lightguide Technology For Adverse Industrial Environments
1987
The lightguide technology has several unique fetures that open up new possibilities of its applications in alverse environments. These factors make this technology attractive in comparizon with classical metal cable based and radio technologies. In the paper we will review relevant works carried out in this country, namely: techno-logical specialization processess for industrial application oriented optical fibres and cables, classification of adverse environments and design rules for cables and optoelectronics, description of our technological facility, fiber optic health protection systems in adverse environments, example of real life applications of ruggedized fibre optic systems in HV/H…
An Investigation of Protection Devices Coordination Effects on Distributed Generators Capacity in Radial Distribution Systems
2013
In the recent years, with the concept of Smart Grid, there are a great interest in integration of renewable energy based distributed generation (DG) units at distribution level. Along with a number of benefits, penetration of DG units in the distribution system imposes some serious challenges; protection requirements turns up as one of the most critical challenge in DG integration. In this paper the possibility and the potentiality of occurring mis-coordination between protection devices in radial distribution network is studied. The impacts of protection devices coordination on DG capacity are investigated. The penetration level, number, and location of interconnected DGs are used as param…
Class Actions or Collective Redress: The Need for an Efficient European Tool
2014
Collective redress makes sense both in court-based litigation and in alternative dispute resolution (ADR). Yet while the courts generally have a good sense of collective redress (though arguably there is room for improvements), in the second framework, there are some contradictions from a dogmatic point of view. When collective interests come up in conflict, judicial coercion and a judicial structure are often needed to resolve the conflict. In addition, the absence of a voluntary agreement, especially from the abuser’s side, makes it more difficult to resolve conflicts using ADR. The future EU Directive in Consumer Collective Redress aims to bring a new era to the field. In this paper, I s…
UPS fuel cell based: An innovative back-up system
2007
The aim of the paper is to evaluate the technical feasibility and aspects related to the use, in an Uninterruptible Power Supply (UPS), of fuel cells instead of traditional electrochemical batteries. The proposed system, named UPS-FCB (Fuel Cell Based) presents a modular and versatile system configuration; particularly it is possible to integrate it with traditional UPS. Moreover the system features can be modified in terms of power, reliability, back-up time, etc., by changing the power devices. A detailed experimental analysis has been carried out on a passive stand-by UPS integrated with a FCB; experimental results can be easily extended to the other possible system architectures. © 2007…