Search results for " Reference"
showing 10 items of 380 documents
Iodine determination in food samples using inductively coupled plasma isotope dilution mass spectrometry.
1998
Two different sample treatment methods are used in connection with inductively coupled plasma isotope dilution mass spectrometry for accurate and precise determinations of iodine traces in food samples. 129I-enriched iodate is applied as a spike compound for the isotope dilution step. Extraction of iodine by tetramethylammonium hydroxide (TMAH) solution at high temperatures in a closed vessel is one of the sample treatment methods. The other one is a complete decomposition of the sample with a mixture of perchloric acid and nitric acid using microwave assistance. By analyzing different certified reference materials (three milk powders with different iodine levels, BCR CRM 63, 150, and 151; …
Soft tissue sarcoma in Italy: From epidemiological data to clinical networking to improve patient care and outcomes
2019
Sarcomas are rare malignant neoplasms that develop from mesenchymal cells and include a heterogeneous and large group of histological subtypes that may occur at any anatomical site. Soft tissue sarcomas (STS), the focus of this review, account for ≈70‒80% of sarcomas and represent <1% of all cancers. The heterogeneity of STS applies to both their topography and morphology, and 5-year survival can vary widely depending on disease stage and the complex interplay between anatomical site and histology for different STS subtypes. The rarity and heterogeneity of STS, together with other factors, such as the lack of clinical expertise often lead to difficulties and delays in making an accurate …
The RAMON module: architecture framework and performance results
2003
A design study of a Re-configurable Access Module for Mobile Computing Applications is described. After a presentation of its cross-layered architecture, Control Parameters (CPs) of the module are introduced. The set of CPs both describes the functional state of the communication process in relation to the time-varying transport facilities and provides, as input of suitable Algorithms, the control information to re-configure the whole protocol stack for facing modified working conditions. The paper also presents the structure of the simulator realized to demonstrate the feasibility of the design guidelines and to evaluate reconfigurability performances.
Assessment of energy management technique for achieving the sustainable voltage level during grid outage of hydro generator interfaced DC Micro-Grid
2021
Abstract An appropriate energy management scheme is needed for the reliable and sustainable operation of DC microgrid. The energy management scheme of DC microgrid (MG) is mainly controlled by main energy resource of MG. Main energy resource needs to be dispatchable unit for forming the reference voltage within DC MG. In this work, a micro hydro generator (MHG) is considered as a dispatchable source for forming the sustainable voltage level of DC MG operating under the abnormal condition. In this work, the abnormality refers to the outage of solar PV due to intermittency during fluctuating load condition. But, due to mechanical time constant of MHG and rate of charging/discharging current l…
An interlaboratory study as useful tool for proficiency testing of chemical oxygen demand measurements using solid substrates and liquid samples with…
2009
In 2008, the first Proficiency Testing Scheme of Chemical Oxygen Demand (1stCOD-PTADG) was conducted to assess the results obtained for different research groups whose field work is mainly anaerobic digestion. This study was performed using four samples, two solid samples as raw materials and two solid samples to prepare high concentration suspended solid solutions. Invitations were sent to a large number of laboratories, mainly to anaerobic digestion research groups. Finally, thirty labs from sixteen countries agreed to participate, but for different reasons four participants could not send any data. In total, twenty-six results were reported to the COD-PT coordinator. This study showed th…
Assessment of Selenium Intake in Relation to Tolerable Upper Intake Levels
2018
Streptococcus agalactiae and Chlamydia trachomatis detection in women without symptoms of infection.
2020
Background Chlamydia trachomatis (C. trachomatis) and Streptococcus agalactiae (GBS) may be present in the female cervical canal without any symptoms of infection. Chronic chlamydial infections lead to many serious complications and perinatal infections, while the presence of GBS is a reservoir for infections of newborns or invasive streptococcal infection in adults. Objectives To examine healthy women for C. trachomatis without symptoms from the reproductive system, assess the frequency of asymptomatic infections, detect GBS in the cervical canal, demonstrate differences in drug susceptibility, and determine the serotype of S. agalactiae strains and correlations among the ones present in t…
Linking Employees’ Extra-Role Efforts to Customer Satisfaction
2017
Abstract. Our main goal was to test the moderating role of customer complaints (“presence” vs. “absence”) in the links from extra-role customer service (ERCS) to customer satisfaction. To this end, we conducted two independent survey studies in two service settings: hotels and service-centers for individuals with intellectual disability. A total of 571 hotel customers and 876 legal guardians of individuals with intellectual disability participated in the studies. We found that the magnitude of the relationship between ERCS and customer satisfaction was higher for presence of complaints than for absence in both service settings. Results are discussed in terms of compensation-seeking, recipr…
Relativistic Positioning Systems in Flat Space-Time: The Location Problem
2013
The location problem in relativistic positioning is considered in flat space-time. When two formal solutions are possible for a user (receiver) of the system, its true location may be obtained from a standard set of emission data extended with an observational rule. The covariant expression giving the location of the user in inertial coordinates is decomposed with respect to an inertial observer.
Simultaneous determinations of zirconium, hafnium, yttrium and lanthanides in seawater according to a co-precipitation technique onto iron-hydroxide
2013
Very low concentrations (pg mL 1 or sub-pg mL 1 level) along with the high salinity are the main problems in determining trace metal contents in seawater. This problem is mainly considered for investigations of naturally occurring YLOID (Y and Lanthanides) and Zr and Hf in order to provide precise and accurate results. The inductively coupled plasma mass spectrometry (ICP-MS), both in high and low resolution, offers many advantages including simultaneous analyses of all elements and their quantitative determination with detection limits of the order of pg mL 1. However in the analysis of YLOID in seawater, a better determination needs an efficient combination of ICP-MS measurement with a pr…