Search results for " Resolution"
showing 10 items of 1159 documents
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods
2015
Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To fur…
Macrophage phenotype in the subclinical gut inflammation of patients with ankylosing spondylitis
2014
OBJECTIVE: Long-term evolution of subclinical gut inflammation to overt Crohn's disease (CD) has been described in AS patients. The aim of this study was to evaluate macrophage polarization occurring in the inflamed gut of patients with AS. METHODS: Twenty-seven HLA-B27(+) AS patients, 20 CD patients and 17 normal controls were consecutively enrolled. Classic M1 (iNOS(+)IL-10(-)), resolution phase (iNOS(+)IL-10(+)), M2 and CD14(+) macrophages were characterized by immunohistochemistry and flow cytometry. Quantitative gene expression analysis of IFN-γ, IL-4, IL-5, IL-33 and STAT6 was performed by real time PCR. RESULTS: Classic M1 macrophages were expanded in CD and AS, where resolution phas…
Management of benign paroxysmal positional vertigo of lateral semicircular canal by Gufoni's manoeuvre
2009
Abstract Benign paroxysmal positional vertigo (BPPV) of lateral semicircular canal (LSC) is one of the rarer forms of BPPV as compared to posterior semicircular canal BPPV. Various particle repositioning manoeuvres have been described in the literature as a mode of treating this condition. Purpose Evaluation and discussion of the procedure of the Gufoni's manoeuvre and its advantages in the treatment of BPPV of LSC. Material and methods Prospective study of 58 patients affected by LSC BPPV who were office-treated with Gufoni's manoeuvre. Results Seventy-nine percent of the patients so treated had complete resolution of symptoms, and 6.9% did not show any improvement in their symptoms. The r…
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
2019
ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …
Impaired conflict resolution and vigilance in euthymic bipolar disorder.
2015
Abstract Difficulty attending is a common deficit of euthymic bipolar patients. However, it is not known whether this is a global attentional deficit or relates to a specific attentional network. According to the attention network approach, attention is best understood in terms of three functionally and neuroanatomically distinct networks-alerting, orienting, and executive control. In this study, we explored whether and which of the three attentional networks are altered in euthymic Bipolar Disorder (BD). A sample of euthymic BD patients and age-matched healthy controls completed the Attention Network Test for Interactions and Vigilance (ANTI-V) that provided not only a measure of orienting…
Evaluation of esophagogastric junction relaxation by 4-second Integrated Relaxation Pressure in achalasia using High Resolution Manometry with water-…
2014
Background Relaxation of the esophagogastric junction (EGJ) is now evaluated calculating 4-second integrated relaxation pressure (4-s IRP) by high resolution manometry (HREPT). Solid-state catheters have been used to define abnormal values. Our aim was to evaluate 4-s IRP in esophageal achalasia using HREPT with perfused catheters. Methods From June 2009 to June 2013, 936 HREPT studies have been performed in our unit. Of these, 194 patients having treated achalasia were excluded. Control group was constituted by 695 patients without achalasia, and 47 patients with untreated achalasia constituted the study group. HREPT was performed with water-perfused catheters. To establish the cut-off val…
Accuracy of staging in early oesophageal cancer using high resolution endoscopy and high resolution endosonography: a comparative, prospective, and b…
2004
The increasing use of endoscopic resection for curative treatment of early oesophageal cancers requires accurate staging before therapy. In a prospective blinded trial, we compared staging of early oesophageal carcinoma using high resolution endoscopy (HR-E) with staging using high resolution endosonography (HR-EUS).A total of 100 patients (89 men, 11 women; mean age 63.9 (10.8) years (range 31-91)) with a suspicion of early oesophageal adenocarcinoma (n = 81) or squamous cell carcinoma (n = 19) were enrolled in the study. After endoscopic staging with high resolution video endoscopy by two experienced endoscopists, HR-EUS was performed by an experienced endosonographer who was blinded to t…
Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…
2009
This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…
Automatic detection and quantification of ground-glass opacities on high-resolution CT using multiple neural networks: comparison with a density mask.
2000
We compared multiple neural networks with a density mask for the automatic detection and quantification of ground-glass opacities on high-resolution CT under clinical conditions.Eighty-four patients (54 men and 30 women; age range, 18-82 years; mean age, 49 years) with a total of 99 consecutive high-resolution CT scans were enrolled in the study. The neural network was designed to detect ground-glass opacities with high sensitivity and to omit air-tissue interfaces to increase specificity. The results of the neural network were compared with those of a density mask (thresholds, -750/-300 H), with a radiologist serving as the gold standard.The neural network classified 6% of the total lung a…