Search results for " Resolution"
showing 10 items of 1159 documents
Long axial crystals for PET applications: The AX-PET demonstrator and beyond
2013
The usage of long, axially oriented scintillator crystals in a PET scanner has been shown by the AX-PET Demonstrator as a possible solution for a high resolution and high sensitivity PET detector. In the AX-PET implementation, arrays of wavelength shifting (WLS) strips, placed orthogonally behind every crystal layer, are used to define the axial coordinate. After extensive characterization measurements, the AX-PET Demonstrator has been successfully used for the reconstruction of several phantoms and a few rodents. Possible extensions of the AX-PET concept towards Time Of Flight capabilities have been investigated, using Philips digital SiPMs as alternative photodetector. Promising CRT value…
Magnetic Field Gradiometer with Sub-Micron Spatial Resolution Based on Caesium Vapour in an Extremely Thin Cell
2015
Abstract In this paper we present a device for measuring the magnetic field and its gradient with a spatial resolution of several hundred nanometres. This device is based on caesium metal vapour confined to an extremely thin cell (ETC). To measure magnetic signals, we use absorption and very low laser powers, which might be appealing for modern fabrication techniques. A portable, fully automated device was constructed.
Spatial and spectral properties of small area THz generation for sub-wavelength microscopy
2010
A highly localized THz source is a promising candidate for sub-wavelength microscopy, due to its superior radiation power throughput with respect to others near-field techniques. Here, we report on the spatial and the spectral near-field properties of our highly localized THz source.
SU-E-I-83: Detectability Limits of a New Positron Emission Mammography in Relation to Tumour-Size, Tumour-To-Background Ratio and Activity Concentrat…
2017
Purpose:Positron emission mammography(PEM) improves spatial resolution and sensitivity, making it suitable for early breast tumours detection. The aim of this study is to evaluate the limits of a dedicated breast PET in terms of tumour‐size, tumour‐to‐background activity concentration ratio (TBR) and activity concentration. Methods: A dedicated PEM is evaluated. To characterize the device, we use a phantom of 15 cm of diameter containing 6 inserts of inner diameters 18, 15, 11, 8, 5 and 3 mm. To evaluate the detectability limits images are acquired by varying the TBR from 10 to 2 and without background activity concentration. In all the studies the activity concentration for the 6 inserts i…
MR-Perfusionsbildgebung des Herzens mit TrueFISP
2001
OBJECTIVE Development and test of a saturation-recovery TrueFISP (SR-Trufi) pulse sequence for myocardial perfusion MR imaging (MRI) using improved gradient hardware. MATERIAL AND METHODS Measurements were performed on a 1.5 T scanner with prototype gradients (50 mT/m, minimum rise time 300 microseconds). T1-weighted first-pass MRI of Gd-DTPA (0.025 mumol/kg) kinetics in the myocardium was performed using an SR-Trufi pulse sequence (TR/TE/alpha = 2.6 ms/1.4 ms/55 degrees) with a saturation preparation of TD = 30 ms before the TrueFISP readout. Measurements were performed in volunteers (n = 4) and in a pig model of chronic ischemia (n = 1). RESULTS In phantoms, the signal intensity was linea…
A new approach for actinic defect inspection of EUVL multilayer mask blanks: Standing wave photoemission electron microscopy
2006
Extreme ultraviolet lithography (EUVL) at 13.5 nm is the next generation lithography technique capable of printing sub-50 nm structures. With decreasing feature sizes to be printed, the requirements for the lithography mask also become more stringent in terms of defect sizes and densities that are still acceptable and the development of lithography optics has to go along with the development of new mask defect inspection techniques that are fast and offer high resolution (preferable in the range of the minimum feature size) at the same time. We report on the development and experimental results of a new 'at wavelength' full-field imaging technique for defect inspection of multilayer mask bl…
Characterization of a pulsed injection-locked Ti:sapphire laser and its application to high resolution resonance ionization spectroscopy of copper
2017
A high repetition rate pulsed Ti:sapphire laser injection-locked to a continuous wave seed source is presented. A spectral linewidth of 20 MHz at an average output power of 4W is demonstrated. An enhanced tuning range from 710-920 nm with a single broadband mirror set is realized by the inclusion of a single thin birefringent quartz plate for suppression of unseeded emission. The spectral properties have been analyzed using both a scanning Fabry-P´erot interferometer as well as crossed beam resonance ionization spectroscopy of the hyperfine levels of natural copper. Delayed ionization of the long-lived excited state is demonstrated for increased resolution. For the excited state hyperfine c…
Conflict resolution in the multi-stakeholder stepped spillway design under uncertainty by machine learning techniques
2021
Abstract The optimal spillway design is of great significance since these structures can reduce erosion downstream of the dams. This study proposes a risk-based optimization framework for a stepped spillway to achieve an economical design scenario with the minimum loss in hydraulic performance. Accordingly, the stepped spillway was simulated in the FLOW-3D® model, and the validated model was repeatedly performed for various geometric states. The results were used to form a Multilayer Perceptron artificial neural network (MLP-ANN) surrogate model. Then, a risk-based optimization model was formed by coupling the MLP-ANN and NSGA-II. The concept of conditional value at risk (CVaR) was utilized…
Geometric constraint solving: The witness configuration method
2006
Geometric constraint solving is a key issue in CAD, CAM and PLM. The systems of geometric constraints are today studied and decomposed with graph-based methods, before their numerical resolution. However, graph-based methods can detect only the simplest (called structural) dependences between constraints; they cannot detect subtle dependences due to theorems. To overcome these limitations, this paper proposes a new method: the system is studied (with linear algebra tools) at a witness configuration, which is intuitively similar to the unknown one, and easy to compute.
MCR-ALS on metabolic networks: Obtaining more meaningful pathways
2015
[EN] With the aim of understanding the flux distributions across a metabolic network, i.e. within living cells, Principal Component Analysis (PCA) has been proposed to obtain a set of orthogonal components (pathways) capturing most of the variance in the flux data. The problems with this method are (i) that no additional information can be included in the model, and (ii) that orthogonality imposes a hard constraint, not always reasonably. To overcome these drawbacks, here we propose to use a more flexible approach such as Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) to obtain this set of biological pathways through the network. By using this method, different constraint…