Search results for " Resolution"

showing 10 items of 1159 documents

Calibration strategy of the JUNO experiment

2021

We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination. [Figure not available: see fulltext.]

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsmeasurement methodsscintillation counter: liquidenergy resolutionFOS: Physical sciencesPhotodetectorScintillator53001 natural sciencesNOHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)hal-03022811PE2_2Optics0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Calibrationlcsh:Nuclear and particle physics. Atomic energy. Radioactivityddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsAstrophysiqueJiangmen Underground Neutrino ObservatoryPhysicsJUNOliquid [scintillation counter]010308 nuclear & particles physicsbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorAstrophysics::Instrumentation and Methods for AstrophysicsLinearityInstrumentation and Detectors (physics.ins-det)calibrationNeutrino Detectors and Telescopes (experiments)lcsh:QC770-798High Energy Physics::ExperimentNeutrinobusinessEnergy (signal processing)Journal of High Energy Physics
researchProduct

Temperature effect on RPC performance in the ARGO-YBJ experiment

2009

The ARGO-YBJ experiment has been taking data for nearly 2 years. In order to monitor continuously the performance of the Resistive Plate Chamber detectors and to study the daily temperature effects on the detector performance, a cosmic ray muon telescope was setup near the carpet detector array in the ARGO-YBJ laboratory. Based on the measurements performed using this telescope, it is found that, at the actual operating voltage of 7.2kV, the temperature effect on the RPC time resolution is about 0.04ns/degrees C and on the particle detection efficiency is about 0.03%/degrees C. Based on these figures we conclude that the environmental effects do not affect substantially the angular resoluti…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaCosmic rayEfficiencytelescopelaw.inventionTelescopeOpticslawAngular resolutionOperating voltagetime resolutionInstrumentationArgoPhysicsMuonbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleAstrophysics::Instrumentation and Methods for AstrophysicsTime resolutionTime resolutionCosmic Ray TelescopeefficiencyRPCHigh Energy Physics::Experimentbusiness
researchProduct

Observation of the cosmic-ray shadow of the Moon with IceCube

2013

We report on the observation of a significant deficit of cosmic rays from the direction of the Moon with the IceCube detector. The study of this "Moon shadow" is used to characterize the angular resolution and absolute pointing capabilities of the detector. The detection is based on data taken in two periods before the completion of the detector: between April 2008 and May 2009, when IceCube operated in a partial configuration with 40 detector strings deployed in the South Pole ice, and between May 2009 and May 2010 when the detector operated with 59 strings. Using two independent analysis methods, the Moon shadow has been observed to high significance (> 6 sigma) in both detector config…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesCosmic rayAstrophysics01 natural sciencesNEUTRINO TELESCOPESPosition (vector)SEARCH0103 physical sciencesShadowAngular resolutionddc:530ARRIVAL DIRECTIONS010303 astronomy & astrophysicsDETECTORAnalysis methodHigh Energy Astrophysical Phenomena (astro-ph.HE)PhysicsANISOTROPY010308 nuclear & particles physicsDetectorSUNAstronomyANGULAR RESOLUTIONEarth's magnetic fieldDeflection (physics)Physics and AstronomyAstrophysics - High Energy Astrophysical Phenomena
researchProduct

Particle identification with the fast COMPASS RICH-1 detector

2009

International audience; A new photon detection system for the COMPASS RICH-1 detector has been designed and installed. In the central region, the project is based on multi-anode photo-multiplier technology accompanied by charge sensitive, high resolution and dead-time free time digitization. In the outer area, only the readout electronics for the existing photon detectors has been replaced. Details on the detector upgrade and its performance are presented.

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsPhoton detectorMulti-anode photo-multiplierComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONHigh resolution[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesCOMPASSParticle identificationTDCParticle identificationOpticsCompass0103 physical sciences010306 general physicsInstrumentationRICHPhysics010308 nuclear & particles physicsbusiness.industryDetectorCharge (physics)Front-end electronicsUpgradeCOMPASS; RICH; Multi-anode photo-multiplier; Particle identification; Front-end electronics; TDCHigh Energy Physics::ExperimentbusinessPhoton detectionFront-end electronic
researchProduct

High resolution detectors based on continuous crystals and SiPMs for small animal PET

2012

International audience; Sensitivity and spatial resolution are the two main factors to maximize in emission imaging. The improvement of one factor deteriorates the other with pixelated crystals. In this work we combine SiPM matrices with monolithic crystals, using an accurate γ-ray interaction position determination algorithm that provides depth of interaction. Continuous crystals provide higher sensitivity than pixelated crystals, while an accurate interaction position determination does not degrade the spatial resolution. Monte Carlo simulations and experimental data show good agreement both demonstrating sub-millimetre intrinsic spatial resolution. A system consisting in two rotating det…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsSiPMMonte Carlo methodHigh resolution01 natural sciencesCoincidence030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplierPosition (vector)0103 physical sciencesHigh resolutionSensitivity (control systems)[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorPosition determinationPETMonolithic crystalsbusiness
researchProduct

Fast Interaction Trigger for ALICE upgrade

2022

We present the structure, functionalities and the first in-beam performance of the ALICE Fast Interaction Trigger (FIT). FIT comprises three detectors: FT0, FV0 and FDD, which use Cherenkov and scintillation effects to detect charged particles originating from proton-proton (pp) and heavy-ion collisions. FIT generates triggers for ALICE, monitors luminosity and background, measures collision time, and determines global collision parameters, such as forward multiplicity, centrality and event plane. FIT uses dedicated front-end electronics to measure time and charge of pulses at pp bunch crossing interval of 25 ns and pp (Pb-Pb) interaction rates of up to 1 MHz (50 kHz). FIT has been installe…

Nuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsdetector performanceTime resolutionhiukkasfysiikkaScintillatorALICE FIT114 Physical sciencesscintillatortrigger detectorAlice fitmittajärjestelmätDetectors and Experimental TechniquesNuclear ExperimentInstrumentationtime resolutionTrigger detectorDetector performanceCherenkov detector
researchProduct

On the performances of a particle tracking detector based on triangular scintillator bars read out by silicon photomultipliers

2020

Abstract A tracking detector composed of scintillator bars with a triangular cross-section read out by silicon photomultipliers in analog mode was developed. The tracker was designed to instrument a low density spectrometer for neutrino experiments. The performance of the system has been studied by exposing it to charged particle beams at the CERN-PS. The tests have shown that the position resolution in reconstructing charged particles’ tracks is within 2.2 mm over the momentum range 0.5–10 GeV/c.

Nuclear and High Energy PhysicsScintillators SiPM Particle tracking device Position resolutionParticle tracking devicePhysics::Instrumentation and DetectorsSiPMScintillatorTracking (particle physics)01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplierParticle tracking device Position resolution Scintillators SiPM0103 physical sciencesInstrumentationPhysicsRange (particle radiation)Spectrometer010308 nuclear & particles physicsbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorCharged particleScintillatorsPosition resolutionHigh Energy Physics::ExperimentNeutrinobusiness
researchProduct

Analysis of spatial diffusion of ferric ions in PVA-GTA gel dosimeters through magnetic resonance imaging

2017

Abstract This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GTA gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an initial steep gradient, were mapped using magnetic resonance imaging on a 7T MRI scanner for small animals. Multiple images of the gels were acquired over several hours after irradiation and were analyzed to quantitatively extract the signal profile. The spatial resolution achieved is 200 μm and this makes this technique particularly suitable for the analysis of steep gradients of ferric ion concentration. The results obtained with PVA-GTA gels were compared with those achieved with agarose gels, which …

Nuclear and High Energy PhysicsSettore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistry01 natural sciences030218 nuclear medicine & medical imagingIon03 medical and health scienceschemistry.chemical_compound0302 clinical medicineNuclear magnetic resonanceMagnetic resonance imagingSpectrophotometry0103 physical sciencesmedicineAgarose gelIrradiationDiffusion (business)Image resolutionInstrumentationAgarose gel; Clinical photons beam; Gel dosimetry; Magnetic resonance imaging; PVA gel; Nuclear and High Energy Physics; InstrumentationSettore CHIM/02 - Chimica Fisicamedicine.diagnostic_test010308 nuclear & particles physicsfungiSettore FIS/01 - Fisica SperimentalePVA gelSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryDiffusion processClinical photons beamFerricAgaroseGel dosimetrySettore MED/36 - Diagnostica Per Immagini E Radioterapiamedicine.drug
researchProduct

A CZT 3D imaging spectrometer prototype with digital readout for high energy astronomy

2023

The scientific challenges still open in hard X-rays and γ-rays astronomy require the development of new instrumentation able to overcome the sensitivity limits of the present one. Among the technologies currently under study to cover the energy range between several tens of keV and one MeV, the development of telescopes equipped with broadband Laue lenses associated with focal planes with high spectroscopic and imaging performance represents an extremely promising solution. With this perspective, we report on the development and the first spectroscopic characterisation results of an X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimension…

Nuclear and High Energy PhysicsSignal digital processingSettore FIS/01 - Fisica Sperimentale3D spatial resolutionInstrumentationCZT spectrometerSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)High energy astronomy
researchProduct

High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment

2020

In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.

Nuclear and High Energy PhysicsSpeichertechnik - Abteilung BlaumPhysics - Instrumentation and DetectorsResolution (mass spectrometry)Physics::Instrumentation and Detectorsenergy resolutionFOS: Physical sciencesElectron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]KATRIN7. Clean energy01 natural sciencesAtomicneutrino massNuclear physicsParticle and Plasma Physicsconversion electronsMetastability0103 physical sciencesNuclearddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)010306 general physicsSpectroscopyNuclear ExperimentPhysicsSpectrometerelectrostatic spectrometer010308 nuclear & particles physicsPhysicskrypton: decayMolecularInstrumentation and Detectors (physics.ins-det)krypton: nuclide530 PhysikcalibrationNuclear & Particles Physicsddc:3. Good healthBeamlineelectron: energy spectrumNeutrinoperformanceKATRIN
researchProduct