The European Photon Imaging Camera on XMM-Newton: The MOS Cameras

2000

The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record the images and spectra of celestial X-ray sources focused by the three X-ray mirrors. There is one camera at the focus of each mirror; two of the cameras contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a circular field of view of 30 arcmin diameter in each case. The CCDs were specially developed for EPIC, and combine high quality imaging with spectral resolution close to the Fano limit. A filter wheel carrying three kinds of X-ray transparent light blocking filter, a fully closed, and a fully open position, is fitted to each EPIC instrument. The CCDs are cooled passively and are under full clos…

PhysicsInstrumentation: detectorPhotonSpectrometerbusiness.industryDynamic rangeAstrophysics::High Energy Astrophysical PhenomenaAstrophysics (astro-ph)Astrophysics::Instrumentation and Methods for AstrophysicsFOS: Physical sciencesAstronomy and AstrophysicsField of viewAstrophysicsAstrophysicsX-rays: generalOpticsCardinal pointSpace and Planetary ScienceCalibrationSpectral resolutionbusinessFocus (optics)
researchProduct

JEM–X: The X-ray monitor aboard INTEGRAL

2003

The JEM-X monitor provides X-ray spectra and imaging with arcminute angular resolution in the 3 to 35 keV band. The good angular resolution and the low energy response of JEM-X plays an important role in the identification of gamma ray sources and in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture instrument consisting of two identical, coaligned telescopes. Each of the detectors has a sensitive area of 500 cm 2 , and views the sky through its own coded aperture mask. The two coded masks are inverted with respect to each other and provides an angular resolution of 3 0 across an eective field of view of about 10 diameter.

PhysicsInstrumentation: detectors; X-rays: general;010504 meteorology & atmospheric sciencesSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaResolution (electron density)Astrophysics::Instrumentation and Methods for AstrophysicsGamma rayAstronomy and AstrophysicsField of viewCosmic rayAstrophysics01 natural sciencesParticle detectorOpticsSpace and Planetary Science0103 physical sciencesAngular resolutionCoded aperturebusiness010303 astronomy & astrophysics0105 earth and related environmental sciencesAstronomy & Astrophysics
researchProduct

A Demonstrator for a new Axial PET Concept

2008

In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…

PhysicsInterleavingInteraction pointPhysics::Instrumentation and Detectorsbusiness.industry3D reconstructionIterative reconstructionSTRIPSlaw.inventionCrystalOpticslawSensitivity (control systems)businessImage resolution2008 IEEE Nuclear Science Symposium Conference Record
researchProduct

Combined high-resolution laser spectroscopy and nuclear decay spectroscopy for the study of the low-lying states inFr206,At202, andBi198

2016

High-resolution laser spectroscopy was performed on $^{206}\mathrm{Fr}$ with the collinear resonance ionization spectroscopy (CRIS) experiment at CERN-ISOLDE. The hyperfine structure and isotope shift of the ground, first isomeric and second isomeric states were measured. The hyperfine components were unambiguously assigned to each nuclear state by means of laser-assisted nuclear decay spectroscopy. The branching ratios in the $\ensuremath{\alpha}$ decay of $^{206}\mathrm{Fr}$ and $^{202}\mathrm{At}$ were also measured for the first time with isomerically purified beams. The extracted hindrance factors allow determination of the spin of the ground, first isomeric, and second isomeric states…

PhysicsIsotope010308 nuclear & particles physicsNuclear stateHigh resolutionchemistry.chemical_element01 natural sciences7. Clean energyFranciumNuclear physicschemistry0103 physical sciencesResonance ionizationPhysics::Atomic and Molecular ClustersPhysics::Atomic PhysicsAtomic physicsNuclear Experiment010306 general physicsSpectroscopyHyperfine structureRadioactive decayPhysical Review C
researchProduct

High-Resolution and Low Resource Time To Digital Converters for the KM3NeT Neutrino Telescope

2015

PhysicsKM3NeTLow resourceNeutrino telescopeAstronomyHigh resolutionAstrophysicsConvertersProceedings of Technology and Instrumentation in Particle Physics 2014 — PoS(TIPP2014)
researchProduct

Analysis of the imaging method for assessment of the smile of laser diode bars.

2009

We study imaging systems designed to assess the smile of laser diode bars (LDBs). The magnification matrix is derived from the required sampling period and the geometries of the LDBs and the charge-coupled device (CCD) array. These image-forming systems present in-plane pure translation invariance, but in the case of anamorphic ones, lack in-plane rotation invariance. It is shown that the smile parameters of the image of the LDB are linked with the smile parameters of the LDB by simple mathematical expressions. The spatial resolution of such optical systems is estimated at approximately 1 microm for a mean wavelength of lambda approximately 800 nm. Our results suggest that, with the current…

PhysicsLaser diodebusiness.industryMaterials Science (miscellaneous)Optical instrumentMagnificationIndustrial and Manufacturing Engineeringlaw.inventionWavelengthOpticslawDigital image processingNear-field scanning optical microscopeBusiness and International ManagementbusinessRotation (mathematics)Image resolutionApplied optics
researchProduct

Shock-cloud interaction in the Vela SNR observed with XMM-Newton

2005

We analyzed an XMM-Newton EPIC observation of a bright knot, named FilD, in the northern rim of the Vela SNR, where the shock has encountered a cloud. The good combination of sensitivity, spectral, and spatial resolution allowed us to describe the internal structure of the observed ISM clouds and to obtain estimates of their temperature, density, O, Ne, and Fe abundances, and of their extension along the line of sight. We also examined the interaction of the shock with the FilD knot and estimated that the time elapsed from the shock impact is about one cloud crushing time. Our analysis allowed us to conclude that the observed X-ray emission is best explained by the propagation of transmitte…

PhysicsLine-of-sightbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics (astro-ph)FOS: Physical sciencesAstronomy and AstrophysicsCloud computingAstrophysicsEPICVelaAstrophysicsX-rays: ISMKnot (unit)ISM: individual objects: Vela SNRSpace and Planetary ScienceISM: cloudISM: kinematics and dynamicbusinessImage resolutionISM: supernova remnantAstrophysics::Galaxy Astrophysics
researchProduct

Accessing fast magnetization dynamics by XPEEM: Status and perspectives

2006

Abstract Being already well established as a versatile technique for high-resolution static magnetic domain imaging, X-ray photoemission electron microscopy (XPEEM) is now also capturing the field of time-resolved magnetic investigations. Using appropriate operation modes at synchrotron radiation sources, a time resolution of 10 ps and less can be achieved in recent magnetodynamics studies, giving access even to phenomena involving precessional processes.

PhysicsMagnetization dynamicsPhotoemission electron microscopyMagnetizationNuclear magnetic resonanceField (physics)Magnetic domainTime resolved spectraSynchrotron radiationTime resolutionCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsComputational physicsJournal of Magnetism and Magnetic Materials
researchProduct

Common-path phase-shifting digital holographic microscopy: A way to quantitative phase imaging and superresolution

2008

We present an experimental setup useful for complex amplitude evaluation and phase image quantification of three-dimensional (3-D) samples in digital holographic microscopy (DHM). It is based on a common-path interferometric configuration performed by dividing the input plane in two contiguous regions and by placing a translation grating near to the Fourier plane. Then, complex amplitude distribution of the sample under test is recovered with phase-shifting standard method obtained by moving the grating using a linear motion stage. Some experimental results of an USAF resolution test are presented for different numerical aperture (NA) microscope lenses. In a second part, the proposed setup …

PhysicsMicroscopebusiness.industryFourier opticsHolographyGratingAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionNumerical apertureLens (optics)OpticslawDigital holographic microscopyElectrical and Electronic EngineeringPhysical and Theoretical ChemistrybusinessImage resolutionOptics Communications
researchProduct

2017

Micro-fluidic pumps as well as artificial micro-swimmers are conveniently realized exploiting phoretic solvent flows based on local gradients of temperature, electrolyte concentration or pH. We here present a facile micro-photometric method for monitoring pH gradients and demonstrate its performance and scope on different experimental situations including an electro-osmotic pump and modular micro-swimmers assembled from ion exchange resin beads and polystyrene colloids. In combination with the present microscope and DSLR camera our method offers a 2 \mu m spatial resolution at video frame rate over a field of view of 3920x2602 \mu m^2. Under optimal conditions we achieve a pH-resolution of …

PhysicsMicroscopebusiness.industryMicrofluidicsGeneral Physics and AstronomyField of view02 engineering and technologyElectrolyteModular design010402 general chemistry021001 nanoscience & nanotechnologyFrame rate01 natural sciences0104 chemical scienceslaw.inventionCharacterization (materials science)law0210 nano-technologyBiological systembusinessImage resolutionNew Journal of Physics
researchProduct