Search results for " Resolution"
showing 10 items of 1159 documents
Automatic analysis of speckle photography fringes
1997
Speckle interferometry is a technique adequate to metrological problems such as the measurement of object deformation. An automatic system of analysis of such measurements is given; it consists of a motorized x-y plate positioner controlled by computer, a CCD video camera, and software for image analysis. A fringe-recognition algorithm determines the spacing and orientation of the fringes and permits the calculation of the magnitude and direction of the displacement of the analyzed object point in images with variable degrees of illumination. For a 256 x 256 pixel image resolution, the procedure allows one to analyze from three fringes to a number of fringes that corresponds to 3 pixels/fri…
Spatial analysis of the homogeneity of the land surface temperature in three Spanish test sites
2015
Calibration and validation cal/val are key activities to test the data quality acquired from satellite-based instruments, as well as to report the accuracy of derived products such as the land surface temperature LST. Calibration of thermal infrared TIR data and validation of LST products at low spatial resolution requires the identification of large and homogeneous areas, which is a difficult task. In this work, spatial and temporal homogeneity of LST was analysed over three Spanish regions: the agricultural area of Barrax, Donana National Park, and Cabo de Gata Natural Park. For this purpose, very high spatial resolution approximately 3 m imagery acquired with the Airborne Hyperspectral S…
<title>Spectral/spatial integration effects on information extraction from multispectral data: multiresolution approaches</title>
1995
New techniques for information extraction from multispectral data require physical modeling to understand the energy transfer at the atmosphere/surface interface and to develop appropriate inversion procedures, in combination with advanced processing techniques. A multi-step procedure is proposed in this work: the first step implies a binary decision about the second step to be applied in each case. If the pixel is considered as being a `pure' pixel, through a spectral/spatial classification procedure based on multiresolution techniques, then numerical inversion techniques, based on a multiple-scattering reflectance model, are used to extract parameters representing specific surface propert…
Influence of pixel size on quantification of airway wall thickness in computed tomography.
2009
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …
Digitale Mehrschichttomographie
1989
A set of projection images is acquired during longitudinal tomography with an image intensifier TV system. Reconstruction of tomograms in each desired plane is achieved by shifting and summing up of the digitalized projection images. Digital multilayer and conventional film tomograms mainly of the respiratory tract and skeleton have been compared in 100 patients. Image quality is comparable with both methods. Disadvantage of digital tomography is lower spatial resolution (512 x 512 matrix size); advantages include lower radiation dose, shorter study time, and facilities of digital imaging.
INTEGRAL/SPI ground calibration
2003
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.
The INTEGRAL IBIS/ISGRI System Point Spread Function and Source Location Accuracy
2003
The imager on board INTEGRAL (IBIS) presently provides the most detailed sky images ever obtained at energies above 30 keV. The telescope is based on a coded aperture imaging system which allows to obtain sky images in a large field of view 29deg x 29deg with an angular resolution of 12'. The System Point Spread Function of the telescope and its detailed characteristics are here described along with the specific analysis algorithms used to derive the accurate point-like source locations. The derived location accuracy is studied using the first in-flight calibration data on strong sources for the IBIS/ISGRI system. The dependence of the calibrated location accuracy with the signal to noise r…
Superresolved imaging of remote moving targets.
2006
We present a superresolving approach that allows one to exceed the diffraction limit and recover highly resolved contours of moving targets from a sequence of low-resolution images. The presented approach is suitable for remote sensing applications. The resolution decoding algorithm that is used to recover the high-resolution features of the target can be run partially via optical means and that way can be used to reduce the required computational complexity.
Multitemporal fusion of Landsat/TM and ENVISAT/MERIS for crop monitoring
2013
Abstract Monitoring Earth dynamics using current and future satellites is one of the most important objectives of the remote sensing community. The exploitation of image time series from sensors with different characteristics provides new opportunities to increase the knowledge about environmental changes and to support many operational applications. This paper presents an image fusion approach based on multiresolution and multisensor regularized spatial unmixing. The approach yields a composite image with the spatial resolution of the high spatial resolution image while retaining the spectral and temporal characteristics of the medium spatial resolution image. The approach is tested using …
Resolution enhancement in integral microscopy by physical interpolation
2015
Integral-imaging technology has demonstrated its capability for computing depth images from the microimages recorded after a single shot. This capability has been shown in macroscopic imaging and also in microscopy. Despite the possibility of refocusing different planes from one snap-shot is crucial for the study of some biological processes, the main drawback in integral imaging is the substantial reduction of the spatial resolution. In this contribution we report a technique, which permits to increase the two-dimensional spatial resolution of the computed depth images in integral microscopy by a factor of √2. This is made by a double-shot approach, carried out by means of a rotating glass…