Search results for " Resolution"

showing 10 items of 1159 documents

Review of thermal infrared applications and requirements for future high-resolution sensors

2016

High-resolution thermal infrared (TIR) remote sensing has a wide range of applications. In this paper, we describe the different applications and requirements identified in a literature review and during a consultation meeting with researcher experts in different fields. As a result, more than 30 applications were identified within three different fields: 1) land and solid Earth; 2) health and hazards; and 3) security and surveillance. A complete set of requirements (spatial, temporal, and radiometric resolution, algorithms used, and supporting data, among others) for each application is also provided. The results presented in this paper provide useful information to enhance the importance …

Thermal infrared010504 meteorology & atmospheric sciencesComputer scienceFuegosathigh resolution0211 other engineering and technologiesHigh resolutionland surface temperatureSettore ING-INF/02 - Campi Elettromagnetici02 engineering and technology01 natural sciencesSet (abstract data type)Fuegosat; high resolution; land surface emissivity; land surface temperature; thermal infraredland surface emissivitySystems engineeringGeneral Earth and Planetary Sciencesthermal infraredElectrical and Electronic EngineeringSolid earth021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensing
researchProduct

Minimum configuration of thermal infrared bands for land surface temperature and emissivity estimation in the context of potential future missions

2014

Abstract A number of applications rely on the availability of high resolution TIR data, both in terms of spatial and temporal resolution, as well as in terms of spectral configuration. A consensus exists among the thermal community regarding the lack of such a kind of data, since only one operational sensor is currently providing multispectral TIR data at high spatial resolution (the case of ASTER, at 90 m spatial resolution and a 16-day revisit time). In this paper we propose a minimum multispectral configuration to allow the retrieval of both land surface temperature (LST) and emissivity ( e ) from thermal infra-red (TIR) data. For this purpose, we propose a minimum configuration based on…

Thermal infraredLand surface temperatureComputer scienceTemporal resolutionMultispectral imageThermalEmissivityHigh spatial resolutionSoil ScienceGeologyComputers in Earth SciencesImage resolutionRemote sensingRemote Sensing of Environment
researchProduct

Land Surface Temperature Retrieval Methods From Landsat-8 Thermal Infrared Sensor Data

2014

The importance of land surface temperature (LST) retrieved from high to medium spatial resolution remote sensing data for many environmental studies, particularly the applications related to water resources management over agricultural sites, was a key factor for the final decision of including a thermal infrared (TIR) instrument on board the Landsat Data Continuity Mission or Landsat-8. This new TIR sensor (TIRS) includes two TIR bands in the atmospheric window between 10 and 12 $\mu\hbox{m}$ , thus allowing the application of split-window (SW) algorithms in addition to single-channel (SC) algorithms or direct inversions of the radiative transfer equation used in previous sensors on board …

Thermal infraredLand surface temperatureMeteorologyInfrared windowRadiative transferEmissivityEnvironmental scienceAtmospheric modelElectrical and Electronic EngineeringGeotechnical Engineering and Engineering GeologyImage resolutionSpectral lineRemote sensingIEEE Geoscience and Remote Sensing Letters
researchProduct

Fluctuation Methods To Study Protein Aggregation in Live Cells: Concanavalin A Oligomers Formation

2011

Prefibrillar oligomers of proteins are suspected to be the primary pathogenic agents in several neurodegenerative diseases. A key approach for elucidating the pathogenic mechanisms is to probe the existence of oligomers directly in living cells. In this work, we were able to monitor the process of aggregation of Concanavalin A in live cells. We used number and brightness analysis, two-color cross number and brightness analysis, and Raster image correlation spectroscopy to obtain the number of molecules, aggregation state, and diffusion coefficient as a function of time and cell location. We observed that binding of Concanavalin A to the membrane and the formation of small aggregates paralle…

Time FactorsCell SurvivalCellSpectroscopy Imaging and Other TechniquesBiophysicsProtein aggregationCell morphologyCell membraneDiffusion03 medical and health scienceschemistry.chemical_compoundMice0302 clinical medicineProtein structure2-NaphthylaminemedicineConcanavalin AAnimalsconfocal microscopy super resolution protein aggregation kinetics in live cells amyloid related pathologiesAnnexin A5Protein Structure QuaternaryCell Shape030304 developmental biology0303 health sciencesbiologySpectrum AnalysisCell MembraneFibroblastsEmbryo MammalianCell biologyMembranemedicine.anatomical_structurechemistryConcanavalin Abiology.proteinLaurdan030217 neurology & neurosurgeryFluorescein-5-isothiocyanateLaurates
researchProduct

Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix.

2012

In emission tomography, iterative statistical methods are accepted as the reconstruction algorithms that achieve the best image quality. The accuracy of these methods relies partly on the quality of the system response matrix (SRM) that characterizes the scanner. The more physical phenomena included in the SRM, the higher the SRM quality, and therefore higher image quality is obtained from the reconstruction process. High-resolution small animal scanners contain as many as 103?104 small crystal pairs, while the field of view (FOV) is divided into hundreds of thousands of small voxels. These two characteristics have a significant impact on the number of elements to be calculated in the SRM. …

Time FactorsRadiological and Ultrasound TechnologyRotationStatistical noisebusiness.industryImage qualityPhantoms ImagingMonte Carlo methodBasis functioncomputer.software_genreNoiseImaging Three-DimensionalVoxelPositron-Emission TomographyRadiology Nuclear Medicine and imagingComputer visionArtificial intelligencebusinesscomputerAlgorithmImage resolutionMonte Carlo MethodSmoothingMathematicsPhysics in medicine and biology
researchProduct

Influence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model

2012

Introduction Cyclic alveolar recruitment/derecruitment (R/D) is an important mechanism of ventilator-associated lung injury. In experimental models this process can be measured with high temporal resolution by detection of respiratory-dependent oscillations of the paO2 (ΔpaO2). A previous study showed that end-expiratory collapse can be prevented by an increased respiratory rate in saline-lavaged rabbits. The current study compares the effects of increased positive end-expiratory pressure (PEEP) versus an individually titrated respiratory rate (RRind) on intra-tidal amplitude of Δ paO2 and on average paO2 in saline-lavaged pigs. Methods Acute lung injury was induced by bronchoalveolar lavag…

Time FactorsRespiratory rateSwinePilot ProjectsLung injuryCritical Care and Intensive Care MedicinePositive-Pressure RespirationRandom AllocationRespiratory Ratevarying shunt fractionsAnimalsMedicineddc:610porcine modelcyclic alveolar recruitmentbusiness.industryResearchLung Injuryrespiratory systemrespiratory- dependent paO 2 oscillationsrespiratory tract diseasesPulmonary AlveoliDisease Models Animalacute lung injuryAnesthesiaHigh temporal resolutionIncreased respiratory ratebusinesscirculatory and respiratory physiologyCritical Care
researchProduct

Protein dynamics observed by tunable mid-IR quantum cascade lasers across the time range from 10 ns to 1 s

2017

We have developed a spectrometer based on tunable quantum cascade lasers (QCLs) for recording time-resolved absorption spectra of proteins in the mid-infrared range. We illustrate its performance by recording time-resolved difference spectra of bacteriorhodopsin in the carboxylic range (1800–1700 cm− 1) and on the CO rebinding reaction of myoglobin (1960–1840 cm− 1), at a spectral resolution of 1 cm− 1. The spectrometric setup covers the time range from 4 ns to nearly a second with a response time of 10–15 ns. Absorption changes as low as 1 × 10− 4 are detected in single-shot experiments at t > 1 μs, and of 5 × 10− 6 in kinetics obtained after averaging 100 shots. While previous time-res…

Time FactorsSpectrophotometry InfraredAbsorption spectroscopyAnalytical chemistry010402 general chemistry53001 natural sciencesMolecular physicsSpectral lineAnalytical Chemistrylaw.inventionchannelrhodopsinflash photolysislawSpectral resolutionAbsorption (electromagnetic radiation)InstrumentationSpectroscopyCarbon MonoxidebiologySpectrometerChemistrybacteriorhodopsinLasers010401 analytical chemistry500 Naturwissenschaften und Mathematik::530 Physik::530 PhysikWaterBacteriorhodopsinLasertime-resolved IR spectroscopyAtomic and Molecular Physics and Optics0104 chemical sciencesSolutionsKineticsCascadeBacteriorhodopsinsmyoglobinbiology.proteinQuantum Theory
researchProduct

Time-Gated Raman Spectroscopy for Quantitative Determination of Solid-State Forms of Fluorescent Pharmaceuticals

2018

Raman spectroscopy is widely used for quantitative pharmaceutical analysis, but a common obstacle to its use is sample fluorescence masking the Raman signal. Time-gating provides an instrument-based method for rejecting fluorescence through temporal resolution of the spectral signal and allows Raman spectra of fluorescent materials to be obtained. An additional practical advantage is that analysis is possible in ambient lighting. This study assesses the efficacy of time-gated Raman spectroscopy for the quantitative measurement of fluorescent pharmaceuticals. Time-gated Raman spectroscopy with a 128 X (2) X 4 CMOS SPAD detector was applied for quantitative analysis of ternary mixtures of sol…

Time Factorsspektroskopia116 Chemical sciencesAnalytical chemistry02 engineering and technologySpectrum Analysis Raman01 natural sciencesSignalAnalytical Chemistrysymbols.namesakeTime domainLeast-Squares Analysista116DETECTORFluorescent DyesSUPPRESSIONta113ta114Chemistry010401 analytical chemistryDetectorMIXTURESSENSORPIROXICAMRESONANCE021001 nanoscience & nanotechnologyRAY-POWDER DIFFRACTIONFluorescence0104 chemical sciencesSPADPharmaceutical PreparationsPHOTON AVALANCHE-DIODETemporal resolutionRaman spectroscopysymbolsCRYSTALLIZATION0210 nano-technologyRaman spectroscopyTernary operationQuantitative analysis (chemistry)
researchProduct

In-situ high spatial resolution LA-MC-ICPMS 230Th/U dating enables detection of small-scale age inversions in speleothems

2017

Abstract We present an in-situ method for Th and U isotope measurements by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) to determine possible age inversions of stalagmites, using a 213 nm Nd:YAG laser connected to an MC-ICPMS. Due to the low ion beam intensity of 230 Th (20–120 counts per second, cps), we carefully optimized the operating parameters to get highest possible ion beam intensities, i.e., laser fluence (25 J cm −2 ), spot size (110 μm), pulse repetition rate (20 Hz), scan speed (4 μm s −1 ), integration time (1000 s), and He and Ar gas flow (∼0.9 L min −1 and ∼0.6 L min −1 respectively). A precision (2 relative standard error, 2RSE) o…

Time delay and integrationIon beamAnalytical chemistryMineralogy010502 geochemistry & geophysics01 natural scienceslaw.inventionGeochemistry and PetrologylawImage resolutionInductively coupled plasma mass spectrometry0105 earth and related environmental sciencesEarth-Surface ProcessesReproducibilityLaser ablationChemistry010401 analytical chemistrylcsh:QE1-996.5GeologySecular equilibriumGeotechnical Engineering and Engineering GeologyLaserSpeleothemLaser ablation0104 chemical scienceslcsh:Geology230Th/U datingGeophysicsMC-ICPMS
researchProduct

Determination of Synchronization of Electrical Activity in the Heart by Shannon Entropy Measure

2005

In this paper we propose a new index of synchronization for the study of heart’s electrical activity during atrial fibrillation (AF). The index relies on the measure of the time delays between correspondent activations in two atrial electrograms and on the characterization of their dispersion by a measure of Shannon Entropy. The algorithm was validated on simulated signals mimicking different degree of synchronization. Results showed the index was able to discriminate among different levels of organization, provided that it works on series of at least 50 activations (time resolution of almost 10 sec during AF). Moreover, we applied the algorithm to real bipolar electrograms, obtained from a…

Time delaysSeries (mathematics)business.industryAtrial fibrillationTime resolutionPattern recognitionmedicine.diseaseMeasure (mathematics)SynchronizationEngineering (all)medicine.anatomical_structureControl theorySettore ING-INF/06 - Bioingegneria Elettronica E InformaticamedicineRight atriumStatistical dispersionArtificial intelligencebusinessMathematics
researchProduct