Search results for " Reverse-Phase"

showing 10 items of 41 documents

Gaining insight in the behaviour of imidazolium-based ionic liquids as additives in reversed-phase liquid chromatography for the analysis of basic co…

2015

In reversed-phase liquid chromatography in the absence of additives, cationic basic compounds give rise to broad and asymmetrical peaks as a result of ionic interactions with residual free silanols on silica-based stationary phases. Ionic liquids (ILs), added to the mobile phase, have been suggested as alternatives to amines to block the activity of silanols. However, the dual character of ILs should be considered: both cation and anion may be adsorbed on the stationary phase, thereby creating a double asymmetrical layer positively or negatively charged, depending on the relative adsorption of both ions. In this work, a study of the performance of six imidazolium-based ILs (the chlorides an…

Chromatography Reverse-PhaseChromatographyTetrafluoroborateOrganic ChemistryCationic polymerizationImidazolesIonic bondingIonic LiquidsGeneral MedicineReversed-phase chromatographyBiochemistryAdrenergic beta-1 Receptor AntagonistsAnalytical Chemistrychemistry.chemical_compoundAdsorptionchemistryChloridesPhase (matter)Ionic liquidBoratesOrganic chemistryAminesTriethylamineChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Approaches to estimate the time and height at the peak maximum in liquid chromatography based on a modified Gaussian model

2011

The time and height at the peak maximum are key parameters to describe a chromatographic peak with prediction or optimization purposes, or in the qualitative/quantitative analysis of samples. Three different approaches to estimate these parameters, using the experimental points in the peak maximum region, are here described and compared. The approaches are based on the reliable description of the peak profile using a modified Gaussian model with a parabolic variance (PVMG). In the first approach, non-linear fitting of the chromatographic data to the PVMG model is carried out to obtain the time and height at the peak maximum (Approach I). In the other two approaches, the PVMG model is linear…

Chromatography Reverse-PhaseSulfonamidesChromatographyLinear fittingChemistryElutionOrganic ChemistryNormal DistributionGeneral MedicineBiochemistryNoise (electronics)Analytical Chemistrysymbols.namesakeModels ChemicalRobustness (computer science)symbolsAlprenololGaussian network modelAlgorithmsJournal of Chromatography A
researchProduct

Sensitive determination of parabens in human urine and serum using methacrylate monoliths and reversed-phase capillary liquid chromatography-mass spe…

2014

A method for the determination of parabens in human urine and serum by capillary liquid chromatography (cLC) with UV-Vis and mass spectrometry (MS) detection using methacrylate ester-based monolithic columns has been developed. The influence of composition of polymerization mixture was studied. The optimum monolith was obtained with butyl methacrylate monomer at 60/40% (wt/wt) butyl methacrylate/ethylene dimethacrylate ratio and 50wt% porogens (composed of 36wt% of 1,4-butanediol, 54wt% 1-propanol and 10wt% water). Baseline resolution of analytes was achieved through a mobile phase of acetonitrile/water in gradient elution mode. Additionally, dispersive liquid-liquid microextraction (DLLME)…

Detection limitAnalytegeographyChromatography Reverse-PhaseChromatographygeography.geographical_feature_categoryResolution (mass spectrometry)ChemistryOrganic ChemistryParabensGeneral MedicineUrineUrinalysisMethacrylateMass spectrometryBiochemistryMass SpectrometryAnalytical ChemistryLiquid chromatography–mass spectrometryLimit of DetectionHumansMethacrylatesMonolithBlood Chemical AnalysisJournal of chromatography. A
researchProduct

Approaches to model the retention and peak profile in linear gradient reversed-phase liquid chromatography.

2012

Abstract The optimisation of the experimental conditions in gradient reversed-phase liquid chromatography requires reliable algorithms for the description of the retention and peak profile. As in isocratic elution, the linear relationship between the logarithm of the retention factor and the solvent contents is only acceptable in relatively small concentration ranges of modifier. However, more complex models may not allow an analytical integration of the general equation for gradient elution. Alternative approaches for modelling the retention in linear gradient elution are here proposed. Those based on the quadratic logarithmic model and a model proposed for normal liquid chromatography yie…

FlavonoidsChromatography Reverse-PhaseIsocratic elutionChromatographyAcetonitrilesLogarithmChemistryElutionOrganic ChemistryAnalytical chemistryWaterGeneral MedicineReversed-phase chromatographyBiochemistryAnalytical ChemistryLinear gradientSolventModels ChemicalGradient elutionDiureticsRetention timeAlgorithmsJournal of chromatography. A
researchProduct

Fast simultaneous determination of prominent polyphenols in vegetables and fruits by reversed phase liquid chromatography using a fused-core column

2015

A reversed-phase high-performance liquid chromatography method with photodiode array detection has been developed enabling the joint determination of 17 prominent flavonoids and phenolic acids in vegetables and fruits. A multi-segmented gradient program using a fused-core column for the separation of several phenolic classes (phenolic acids and flavonoids) has been optimised. The influence of extraction conditions (sample freeze-drying, ultrasound extraction, solvent composition and extraction time) has been also optimised using response surface methodology with tomato samples as a model. Complete recoveries (76-108%) were obtained for the phenolic compounds present in tomato. The developed…

HPLC-DADAnalytical ChemistryFused corePhenolsResponse surface methodologyLimit of DetectionVegetablesResponse surface methodologyChromatography High Pressure LiquidFlavonoidsDetection limitChromatography Reverse-PhaseChromatographyChemistryExtraction (chemistry)Polyphenolsfood and beveragesGeneral MedicineReversed-phase chromatographyRepeatabilityGENETICAFunctional qualityPolyphenolFoodFruitUltrasound-assisted extractionResponse Surface MethodologyColumn (botany)Food Science
researchProduct

Modelling the enantioresolution capability of cellulose tris(3,5-dichlorophenylcarbamate) stationary phase in reversed phase conditions for neutral a…

2018

[EN] To the best of our knowledge, the prediction of the enantioresolution ability of polysaccharides-based stationary phases in liquid chromatography for structurally unrelated compounds has not been previously reported. In this study, structural information of neutral and basic compounds is used to model their enantioresolution levels obtained from an immobilised cellulose tris(3,5-dichlorophenylcarbamate) stationary phase in reversed phase conditions. Thirty-four structurally unrelated chiral drugs and pesticides, from seven families, are studied. Categorical enantioresolution levels (RsC, 0 = no baseline enantioresolution and 1 = baseline enantioresolution) are established from the expe…

Models MolecularTrisPhenylcarbamatesEnantioresolution modelling01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundMolecular descriptorPhase (matter)Tris(35-dichlorophenylcarbamate)MoleculeLeast-Squares AnalysisPesticidesCelluloseCelluloseChromatography High Pressure LiquidReversed phase liquid chromatographyEnantioseparationsChromatography Reverse-PhasePrincipal Component AnalysisChromatography010405 organic chemistry010401 analytical chemistryOrganic ChemistryDiscriminant partial least squaresDiscriminant AnalysisStereoisomerismGeneral MedicineReversed-phase chromatography0104 chemical scienceschemistryStationary phaseAsymmetric carbonStationary phaseJournal of Chromatography A
researchProduct

Ultra-short ion-exchange columns for fast charge variants analysis of therapeutic proteins

2021

Abstract The purpose of this work was to study the potential of recently developed ultra-short column hardware for ion exchange chromatography (IEX). Various prototype and commercial columns having lengths of 5, 10, 15, 20 and 50 mm and packed with non-porous 3 µm particles were systematically compared. Both pH and salt gradient modes of elution were evaluated. Similarly, what has been previously reported for reversed phase liquid chromatography (RPLC) mode, an “on-off” retention mechanism was observed in IEX for therapeutic proteins and their fragments (25–150 kDa range). Because of the non-porous nature of the IEX packing material, the column porosity was relatively low (e = 0.42) and the…

Monoclonal antibodyChromatography Reverse-PhaseRange (particle radiation)ddc:615ChromatographyIon exchangeChemistryElutionOrganic ChemistryIon chromatographyIon-exchange chromatographyGeneral MedicineReversed-phase chromatographyChromatography Ion ExchangeBiochemistryUltra-short columnExtra-column volumeAnalytical ChemistryVolume (thermodynamics)PeekPorosityFast separationPorosityChromatography High Pressure Liquid
researchProduct

Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

2017

[EN] In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch®), or mixtures of H2O2 and H2SO4, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification…

Monolithic HPLC columnMicrobore column02 engineering and technology01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundSurface modificationQUIMICA ANALITICAEnvironmental ChemistryMonolith attachmentMonolithReversed-phase liquid chromatographyPolytetrafluoroethyleneSpectroscopychemistry.chemical_classificationChromatography Reverse-PhasegeographyChromatographygeography.geographical_feature_categoryPolytetrafluoroethyleneChemistry010401 analytical chemistryPolymer monolithEquipment DesignPolymer021001 nanoscience & nanotechnology0104 chemical sciencesChemical engineeringPolymerizationAttenuated total reflectionSurface modificationAlkylbenzenes0210 nano-technologyAnalytica Chimica Acta
researchProduct

Bimodal copper oxide nanoparticles doped phase for the extraction of highly polar compounds by in-tube solid-phase microextraction coupled on-line to…

2020

Abstract Polymers obtained from tetraethyl orthosilicate (TEOS) and triethoxymethylsilane (MTEOS) have been functionalized with different metal and metal oxide nanoparticles (NPs), and used as coatings of extractive capillaries for the extraction of polar compounds by in-tube solid-phase microextraction (IT-SPME) coupled on-line to nano-liquid chromatography (nano-LC). The extraction capabilities of the new phases have been studied using several triazinic herbicides with log of octanol/water partition coefficients (Kow) ranging from -0.7 to 3.21 under reversed phase chromatographic conditions. Best extraction efficiencies for the most polar compounds (log Kow ≤ 2.3) were typically obtained …

OctanolPolymersMetal NanoparticlesWastewater010402 general chemistrySolid-phase microextraction01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionPhase (matter)SeawaterSolid Phase MicroextractionDetection limitChromatography Reverse-PhaseChromatographyHerbicidesTriazinesChemistryHydrophilic interaction chromatography010401 analytical chemistryOrganic ChemistryExtraction (chemistry)TryptophanGeneral MedicineSilanes0104 chemical sciencesTetraethyl orthosilicatePartition coefficientTyrosineHydrophobic and Hydrophilic InteractionsCopperWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Comparison of monolithic and microparticulate columns for reversed-phase liquid chromatography of tryptic digests of industrial enzymes in cleaning p…

2011

Abstract Enzymes of several classes used in the formulations of cleaning products were characterized by trypsin digestion followed by HPLC with UV detection. A polymeric monolithic column (ProSwift) was used to optimize the separation of both the intact enzymes and their tryptic digests. This column was adequate for the quality control of raw industrial enzyme concentrates. Then, monolithic and microparticulate columns were compared for peptide analysis. Under optimized conditions, the analysis of tryptic digests of enzymes of different classes commonly used in the formulation of cleaning products was carried out. Number of peaks, peak capacity and global resolution were obtained in order t…

Peptide analysisChromatography Reverse-PhaseMonolithic HPLC columnChromatographyResolution (mass spectrometry)ChemistryOrganic ChemistryDetergentsReproducibility of ResultsGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyPeptide FragmentsAnalytical ChemistryEnzymesIndustrial enzymesTrypsinTrypsin DigestionUv detectionJournal of chromatography. A
researchProduct