Search results for " Senso"
showing 10 items of 1766 documents
Physical capacity in performing daily activities is reduced in scleroderma patients with early lung involvement
2014
BACKGROUND: Patients with systemic sclerosis (SSc) often complain reduced capacity at submaximal exercise; conversely physical capacity in performing daily duties has never been measured in SSc. OBJECTIVES: To evaluate this performance and its correlates, in patients with SSc compared to healthy controls, in a free-living setting. METHODS: Twenty-seven outpatients with stable SSc and 11 controls were recruited. Physical activity was assessed by portable multiple sensor device (SenseWear Armband) worn for at least six days. Physical activity duration (PAD; in minutes) for non-sedentary activities and physical activity level (PAL= total daily energy/resting energy expenditure) per day were ca…
Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius
2008
Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-differ…
Characteristics of tinnitus with or without hearing loss: Clinical observations in Sicilian tinnitus patients
2010
Objective: To analyze the clinical characteristics of tinnitus both in normal hearing subjects and in patients with hearing loss. Methods: The study considered 312 tinnitus sufferers, 176 males and 136 females, ranging from 21 to 83 years of age, who were referred to the Audiology Section of the Department of Bio-technology of Palermo University. The following parameters were considered: age, sex, hearing threshold, tinnitus laterality, tinnitus duration, tinnitus measurements and subjective disturbance caused by tinnitus. The sample was divided into two groups: Group 1 (G1) subjects with normal hearing; Group 2 (G2) subjects with hearing loss. Results: Among the patients considered, 115 ha…
Pointing to double-step visual stimuli from a standing position: motor corrections when the speed-accuracy trade-off is unexpectedly modified in-flig…
2011
The time required to complete a fast and accurate movement is a function of its amplitude and the target size. This phenomenon refers to the well known speed-accuracy trade-off. Some interpretations have suggested that the speed-accuracy trade-off is already integrated into the movement planning phase. More specifically, pointing movements may be planned to minimize the variance of the final hand position. However, goal-directed movements can be altered at any time, if for instance, the target location is changed during execution. Thus, one possible limitation of these interpretations may be that they underestimate feedback processes. To further investigate this hypothesis we designed an ex…
Prism adaptation by mental practice
2012
International audience; The prediction of our actions and their interaction with the external environment is critical for sensorimotor adaptation. For instance, during prism exposure, which deviates laterally our visual field, we progressively correct movement errors by combining sensory feedback with forward model sensory predictions. However, very often we project our actions to the external environment without physically interacting with it (e.g., mental actions). An intriguing question is whether adaptation will occur if we imagine, instead of executing, an arm movement while wearing prisms. Here, we investigated prism adaptation during mental actions. In the first experiment, participa…
Timing flickers across sensory modalities
2009
In tasks requiring a comparison of the duration of a reference and a test visual cue, the spatial position of test cue is likely to be implicitly coded, providing a form of a congruency effect or introducing a response bias according to the environmental scale or its vectorial reference. The precise mechanism generating these perceptual shifts in subjective duration is not understood, although several studies suggest that spatial attentional factors may play a critical role. Here we use a duration comparison task within and across sensory modalities to examine if temporal performance is also modulated when people are exposed to spatial distractors involving different sensory modalities. Di…
Brainstem evoked potentials and magnetic resonance imaging abnormalities in differential diagnosis of intracranial hypotension.
2019
Summary Objective To compare brainstem acoustic evoked potentials (BAEP) and magnetic resonance imaging (MRI) in the differential diagnosis of intracranial hypotension (IH), Chiari malformation (CM) and sensorineural hearing loss (SNHL). Methods BAEP were recorded in 18 IH, 18 CM, 20 SNHL patients and 52 controls. MRI were acquired in all IH and CM patients. Results Abnormal BAEP were observed in 94% of IH patients, in 33% of CM and 70% of SNHL patients. After recovery from IH, BAEP abnormalities disappeared. Internal auditory canal (IAC) MRI abnormalities were described in 88% of IH patients. MRI signs of IH were observed in 33–78% in IH patients, but the most frequent MRI sign was 8th ner…
Hearing loss in Fabry disease: data from the Fabry Outcome Survey
2006
Hearing loss is a common symptom in Fabry disease, but neither its natural course nor its aetiology has been defined precisely. The aim of this study was to provide a detailed epidemiological description of hearing impairment in patients in the Fabry Outcome Survey (FOS), which is the largest available database of Fabry patients. Questionnaires were completed by 566 Fabry patients, of whom 316 reported ear-related symptoms. Pure-tone audiograms from 86 patients, performed before starting enzyme replacement therapy, were analysed and compared with age- and sex-specific normal values (International Organization for Standardization, ISO 7029). When compared to an age-matched population (ISO 70…
Cochlear origin of early hearing loss in vestibular schwannoma.
2007
Objective: To test whether early hearing loss (HL) is cochlear in origin in patients with vestibular schwannoma (VS). Study Design: Retrospective case review in an academic tertiary referral center. Methods: A group of 19 VS patients with normal/symmetrical hearing and a group of 20 VS patients with mild HL (threshold at any tested frequency better than 45 dB HL) on the tumor ear side. Differences of the amplitudes of the distortion products of otoacoustic emissions (DPOAEs) between the tumor ear and the nontumor ear were studied at frequencies of 1, 1.4, 2, 2.8, and 4 kHz. The Wilcoxon test was used to compare the ears for both groups and to test for possible differences in tumor size betw…
Piezosurgery in endoscopic dacryocystorhinostomy
2009
Piezosurgery is a recently developed system for cutting bone with microvibrations. The equipment consists of two hand pieces, two inserts, and two peristaltic pumps connected to the control unit. The device is endowed with an irrigation system of high-flow saline solution that breaks up into very small particles, with a “bloodless” effect on the surgical site and a low indirect thermal damage to the bone surfaces and adjacent structures. 4,5 The touch screen of the main unit permits selection of the specific insert, and modulation of the irrigation and the power according to the bone density. The device uses low-frequency ultrasonic waves (24.7-29.5 kHz), the applied power can be modulated …