Search results for " Spectrometry"

showing 10 items of 2771 documents

A highly selective laser ion source for bunched, low emittance beam release

2004

A novel type of resonance ionization laser ion source (RILIS) is under development, which combines the advantages of laser ionization with those of a source-implemented ion trap. This laser ion source trap (LIST) system, based on a gas-filled linear radio-frequency quadrupole ion trap, decouples the evaporation and ionization process by introduction of a primary surface ion repeller. Apart from significantly enhancing the selectivity in radioactive ion beam production, optimum control on the temporal pulse structure and the emittance of the generated laser ion bunch is obtained. A variety of operational modes from quasi-dc to microseconds-bunched ion beams with variable repetition rate can …

PhysicsNuclear and High Energy PhysicsIon beamIon gunIon sourcelaw.inventionSecondary ion mass spectrometryIon beam depositionPhysics::Plasma PhysicsReflectronlawPhysics::Accelerator PhysicsPhysics::Atomic PhysicsIon trapAtomic physicsQuadrupole ion trapNuclear Physics A
researchProduct

Determination of several aminoglycoside and macrolide antibiotics in animal tissues by liquid chromatography-electrospray ionization-tandem mass spec…

2008

ChromatographyLiquid chromatography electrospray ionization tandem mass spectrometryProtein mass spectrometryLiquid chromatography–mass spectrometrymedicine.drug_classChemistryAminoglycosidemedicineGeneral MedicineToxicologySample preparation in mass spectrometryMacrolide AntibioticsToxicology Letters
researchProduct

Calibration transfer in chemiluminescence analysis

2001

Abstract Direct standardization (DS) and piecewise direct standardization (PDS) methods are applied to multivariate standardization of chemiluminescence signals using PLS model as the calibration model. The linear concentration interval of the chemiluminescence determination was determined. This interval was located using univariate robust calibration by least median of squares (LMS) method. The linear calibration model was corroborated by conventional least-squares method. The standardization subset and window size were optimized by means of the prediction residual error sum of squares. Several instrumental sources of variability have been studied: the detection cell, instrument, batch ver…

Calibration (statistics)Explained sum of squaresFluorescence spectrometryAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionLuminolChemometricschemistry.chemical_compoundchemistrylawLinear regressionEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

Label-Free Proteomics of Quantity-Limited Samples Using Ion Mobility-Assisted Data-Independent Acquisition Mass Spectrometry

2021

Over the past two decades, unbiased data-independent acquisition (DIA) approaches have gained increasing popularity in the bottom-up proteomics field. Here, we describe an ion mobility separation enhanced DIA workflow for large-scale label-free quantitative proteomics studies where starting material is limited. We set a special focus on the single pot solid-phase-enhanced sample preparation (SP3) protocol, which is well suited for the processing of quantity-limited samples.

0303 health sciencesComputer science030302 biochemistry & molecular biologyQuantitative proteomicsMass spectrometryProteomicsIon03 medical and health sciencesLabel-free quantificationSample preparationData-independent acquisitionBottom-up proteomicsBiological system030304 developmental biology
researchProduct

An electrospray ionization Fourier transform ion cyclotron resonance mass spectrometric study of the gas-phase stabilities and fragmentation ofN-alky…

2006

Five N-alkylated ammonium resorcarene derivatives, differing either in the nitrogen atom or in the lower rim alkyl chain, were studied using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. The main purpose was to clarify the fragmentation and the relative stabilities of the protonated molecules by collision-induced dissociation (CID) experiments. The results indicate that fragmentation of the upper rim alkyl amino substituents at the 2-position occurs readily. Variation in the gas-phase stabilities of these molecules was also observed. In addition, the proposed fragmentation pathways are depicted.

Spectrometry Mass Electrospray IonizationChemical ionizationAlkylationCollision-induced dissociationChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryResorcinolsCyclotronsMass spectrometryPhase TransitionIon sourceFourier transform ion cyclotron resonanceAnalytical ChemistryQuaternary Ammonium CompoundsFragmentation (mass spectrometry)OxazinesSpectroscopy Fourier Transform InfraredGasesSpectroscopyIon cyclotron resonanceRapid Communications in Mass Spectrometry
researchProduct

Penning-trap mass measurements on 92, 94-98, 100Mo with JYFLTRAP

2012

Penning-trap measurements on stable 92, 94-98, 100Mo isotopes have been performed with relative accuracy of \ensuremath1⋅10−8\ensuremath1⋅10−8 with the JYFLTRAP Penning-trap mass spectrometer by using 85Rb as a reference. The Mo isotopes have been found to be about 3keV more bound than given in the Atomic Mass Evaluation 2003 (AME03). The results confirm that the discrepancy between the ISOLTRAP and JYFLTRAP data for 101-105Cd isotopes was due to an erroneous value in the AME03 for 96Mo used as a reference at JYFLTRAP. The measured frequency ratios of Mo isotopes have been used to update mass-excess values of 30 neutron-deficient nuclides measured at JYFLTRAP. peerReviewed

nuclear spectroscopyPhysicsNuclear and High Energy PhysicsMass excessIsotopeaccelerator-based physicsPenning trapMass spectrometrykiihdytinpohjainen fysiikkaISOLTRAPAtomic massNuclear physicsydinrakennenuclear structureydinspektroskopiaNuclear fusionNuclideAtomic physicsydinfysiikkaThe European Physical Journal A
researchProduct

High-accuracy mass determination of unstable cesium and barium isotopes

1999

Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\delta \mbox{m} \approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

PhysicsNuclear and High Energy PhysicsIsotope[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]010308 nuclear & particles physicschemistry.chemical_element[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap7. Clean energy01 natural sciencesISOLTRAPAtomic massNuclear physicsMasschemistryCaesium0103 physical sciencesNuclear Physics - ExperimentAtomic physicsNuclear Experiment010306 general physicsHybrid mass spectrometer
researchProduct

Release of copper-amended particles from micronized copper-pressure-treated wood during mechanical abrasion

2016

Background We investigated the particles released due to abrasion of wood surfaces pressure-treated with micronized copper azole (MCA) wood preservative and we gathered preliminary data on its in vitro cytotoxicity for lung cells. The data were compared with particles released after abrasion of untreated, water (0% MCA)-pressure-treated, chromated copper (CC)-pressure-treated wood, and varnished wood. Size, morphology, and composition of the released particles were analyzed. Results Our results indicate that the abrasion of MCA-pressure-treated wood does not cause an additional release of nanoparticles from the unreacted copper (Cu) carbonate nanoparticles from of the MCA formulation. Howev…

0301 basic medicinePreservativeCopper particlesAbrasion (mechanical)Cell SurvivalCytotoxicityIn vitro cytotoxicityBiomedical EngineeringNanoparticlechemistry.chemical_elementMedicine (miscellaneous)Pharmaceutical ScienceBioengineering010501 environmental sciences01 natural sciencesApplied Microbiology and BiotechnologyMass SpectrometryCell LineExposure03 medical and health sciencesPressureHumansCytotoxicity0105 earth and related environmental sciencesChemistryResearchtechnology industry and agricultureWaterCytotoxicity; Copper particles; Debris; Exposure; Inhalation; Wood dustMechanical abrasionCopperWood030104 developmental biologyInhalationA549 CellsMolecular MedicineNanoparticlesComposition (visual arts)DebrisReactive Oxygen SpeciesCopperWood dustNuclear chemistry
researchProduct

Status of the project TRAPSENSOR: Performance of the laser-desorption ion source

2013

Abstract Penning traps provide mass measurements on atomic nuclei with the highest accuracy and sensitivity. Depending on the experiment and on the physics goal, a relative mass uncertainty varying from 10 −7 to below 10 −11 is required. Regarding sensitivity, the use of only one ion for the measurement is crucial, either to perform mass measurements on superheavy elements (SHE), or to reach δ m / m ≈ 10 - 11 in order to contribute to the direct determination of the mass of the electron-antineutrino with accurate mass measurements on specific nuclei. This has motivated the development of a new technique called Quantum Sensor based on a laser-cooled ion stored in a Penning trap, to perform m…

Nuclear and High Energy PhysicsChemistry010401 analytical chemistryQuantum sensorMass spectrometryPenning trap7. Clean energy01 natural sciencesIon source0104 chemical sciencesComputational physicsIonSecondary ion mass spectrometry0103 physical sciencesIon trapTime-of-flight mass spectrometryAtomic physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Commercial essential oils: sustainable alternatives in the agri-food industry

2019

Essential oils have enjoyed great popularity from ancient times to today due to agreeable scent and widely known beneficial properties. As a result, nowadays they have become valuable natural ingredients in perfume and cosmetics, food and beverages, agricultural, pharmaceutical and other industries for employment in human health, agriculture and environment, representing potentially safer and more sustainable alternatives to synthetic substances. This Doctoral Thesis has been developed with the aim of corroborating that essential oils are safer and more sustainable alternatives to synthetic products used in the agri-food industry, and consequently promoting their use as “bio” products to ma…

antimicrobial activityUNESCO::CIENCIAS MÉDICAS ::Farmacología ::Farmacognosiaantioxidant activityfood cropsphytotoxicityhumanitiesgas chromatography-mass spectrometry:CIENCIAS MÉDICAS ::Farmacología ::Farmacognosia [UNESCO]invasive speciesextrusionagri-food industryessential oilsmicrocrystalline celluloseweed
researchProduct