Search results for " Stan"
showing 10 items of 1695 documents
Determination of organochlorine pesticide residues in honey from the central zone of Portugal and the Valencian community of Spain
2004
In this study nine organochlorine pesticide residues ([alpha]-, [beta]-, and [gamma]-hexachlorocyclohexane (HCH), hexachlorobenzene (HCB), aldrin, p,p'-DDE, p,p'-DDD, o,p'-DDT, and p,p'-DDT) in forty nine samples of honey collected from markets of Portugal and Spain during 2001 and 2002, respectively, were evaluated. For this evaluation, three analytical procedures were studied. The analytical procedure, based on LLE extraction with ethyl acetate followed by gas chromatography-electron-capture detection (GC-ECD) for quantification, and mass spectrometry (GC-MS) for confirmation, has been selected. Recoveries of spiked samples ranged from 68%, for [beta]-HCH, and 126% for p,p'-DDT, for forti…
Processing of Generator-Produced 68Ga for Medical Application
2007
The (68)Ge/(68)Ga generator provides an excellent source of positron-emitting (68)Ga. However, newly available "ionic" (68)Ge/(68)Ga radionuclide generators are not necessarily optimized for the synthesis of (68)Ga-labeled radiopharmaceuticals. The eluates have rather large volumes, a high concentration of H(+) (pH of 1), a breakthrough of (68)Ge, increasing with time or frequency of use, and impurities such as stable Zn(II) generated by the decay of (68)Ga, Ti(IV) as a constituent of the column material, and Fe(III) as a general impurity.We have developed an efficient route for the processing of generator-derived (68)Ga eluates, including the labeling and purification of biomolecules. Prec…
Immobilization of reagents by polymeric materials. Determination of metamizol
1992
Abstract A method for immobilization of inorganic reagents, based on the dispersion of the reagent into an unsaturated polyester solution is applied to immobilization of lead dioxide. The obtained solid is of application in a flow-injection manifold for indirect atomic absorption determination of metamizol in pharmaceutical formulations. The procedure gives a linear calibration graph up to 6 ppm of metamizol with a relative standard deviation of 1.6% (3.0 mg/l) and a sample throughput of 72 hr−1.
Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry
2007
An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…
Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…
2002
A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…
Determination of trichothecenes in chicken liver using gas chromatography coupled with triple-quadrupole mass spectrometry
2018
Abstract Chicken meat and edible offal are included in a wide number of preparations in the worldwide cuisine. Among the offal, the liver is one of the most consumed in some countries like Egypt since it is rich in proteins and is an economical source of many essential nutrients for humans. Mycotoxins, secondary toxic metabolites produced by fungi, have the potential to enter human food chain not only with cereal consumption but also through edible tissues from animals fed with mycotoxin-contaminated feed. Accordingly, a rapid method for the determination of eight trichothecenes in chicken liver was developed based on a quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction an…
Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection.
1999
A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20-2000 ng/ml. The recovery of busulfan from plasma standards was 70+/-5%. The detection and quantification limits for busulfan in plasma sample…
Emerging approaches to estimate retention factors in high performance liquid chromatography.
2004
The retention factor is one of the most universally used parameters in chromatography. The errors associated with the conventional ways to determine the retention factor of compounds in liquid chromatography are studied and compared with those corresponding to new approaches. The later avoid the use of extra-column time and hold-up time values, which have proven to be tedious and ambiguous. Simulations and real data, used to examine the accuracy of four different approaches (two classic and two new), suggest that the new approaches could be considered more satisfactory than the classic ones.
Development of standard operation procedures for the manufacture of n-octadecyl bonded silicas as packing material in certified reference columns for…
2004
The development of standard operation procedures for the manufacture of a n-octadecyl bonded spherical silica packing from partially condensed tetraethoxysilane as silica source is described. The synthesis comprises five intermediate products and six synthesis steps which were examined according to their reproducibility and robustness. The results led to the optimisation of the manufacturing process for a n-octadecyl bonded silica. Correlations were drawn between the dynamic viscosity of the poly(ethoxy)siloxane (PES), the synthesis parameters, the resulting pore structural properties and particle size distribution of the silicas. Validated procedures were developed to manufacture spherical…
Target analysis of primary aromatic amines combined with a comprehensive screening of migrating substances in kitchen utensils by liquid chromatograp…
2015
An analytical strategy including both the quantitative target analysis of 8 regulated primary aromatic amines (PAAs), as well as a comprehensive post-run target screening of 77 migrating substances, was developed for nylon utensils, using liquid chromatography-orbitrap-high resolution mass spectrometry (LC-HRMS) operating in full scan mode. The accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), and by alternating two acquisition events, ESI+ with and without fragmentation. The target method was validated after statistical optimization of the main ionization and fragmentation parameters. The quantitative method presented appropriate performance to be u…