Search results for " Stents"
showing 10 items of 57 documents
Bioresorbable polymer-coated thin strut sirolimus-eluting stent vs durable polymer-coated everolimus-eluting stent in daily clinical practice: Propen…
2018
Objectives We sought to determine the 1-year clinical follow-up in patients treated with the thin strut (71 μm) bioabsorbable polymer-coated sirolimus-eluting stent (BP-SES) vs durable coating everolimus eluting stent (DP-EES) in daily clinical routine. Background Presence of durable polymers may be associated with late/very late stent thrombosis occurrence and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. Methods Interventional Cardiology Network Registry is a prospective, multicenter, observational registry of 21,400 consecutive patients treated with PCI since 2010. We analyzed 4,670 patients treated …
Early outcomes with a single-sided access endovascular stent
2018
Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …
Initial experience with the novel BioMime 60 mm-long sirolimus-eluting tapered stent system in long coronary lesions
2017
Real world safety and efficacy of the Janus Tacrolimus-Eluting stent: long-term clinical outcome and angiographic findings from the Tacrolimus-Elutin…
2009
Objectives: We sought to evaluate the safety and performance of the Janus Tacrolimus-Eluting stent (TES) in an unselected population of patients, without application of restrictive clinical or angiographic criteria. Background: Continued attention to the safety, efficacy, and deliverability of first-generation drug eluting stents has led to the development of new antiproliferative agents with alternative stent platforms and different drug carrier vehicles. Methods: The TEST (Tacrolimus Eluting STent) registry is a prospective, nonrandomized single-center registry in which 140 consecutive patients who underwent single- or multi-vessel percutaneous coronary intervention between February 2005 …
Feasibility of Implanting 50-60 mm-Tapered Drug Eluting Stents in Chronic Total Occlusions.
2018
Abstract Background Percutaneous coronary intervention (PCI) of chronic total occlusions (CTO) usually involves multiple overlapping stents implantation to cover long coronary segments. A higher rate of restenosis has been described with stent overlapping. Recently, new long tapered stents emerged as a potential tool for treating long coronary lesions. Feasibility of using these new devices for the CTO PCI has not been described. The aim of this work was to describe our initial experience with 50 and 60 mm-long tapered sirolimus-eluting stents (SES) in CTO PCI. Methods We included 54 consecutive patients who underwent a CTO PCI and in whom an attempt to implant a 50 or 60 mm-long tapered SE…
Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year fo…
2017
Objectives to compare the 1-year outcome between bioresorbable vascular scaffold (BVS), everolimus-eluting stent (EES), and drug-eluting balloon (DEB) for in-stent restenosis (ISR) treatment. Background BVS has been proposed as alternative for ISR treatment. To date a direct comparison between BVS and DES or DEB for ISR treatment is lacking. Methods We retrospectively analyzed all ISR lesions treated with BVS, DEB, and EES from January 2012 to December 2014. A total of 548 lesions (498 patients) were included. By applying two propensity-score matching, 93 lesions treated with BVS were compared with 93 lesions treated with DEB, and 100 lesions treated with BVS were compared to 100 lesions tr…
Diagnostic accuracy of 64-slice CT in the assessment of coronary stents
2007
PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml,…
Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography
2008
BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…
Long-term outcomes of percutaneous coronary interventions or coronary artery bypass grafting for left main coronary artery disease in octogenarians (…
2014
Percutaneous coronary intervention (PCI) with drug-eluting stents is an accepted alternative to surgery for the treatment of unprotected left main coronary artery (ULMCA) disease, but the long-term outcome in elderly patients is unclear. Aim of our study was to compare the clinical outcomes of octogenarians with ULMCA disease treated either with PCI with drug-eluting stents or coronary artery bypass grafting (CABG). The primary study end point was the composite of death, cerebrovascular accident, and myocardial infarction at follow-up. A total of 304 consecutive patients with ULMCA stenosis treated with PCI or CABG and aged 80 years were selected and analyzed in a large multinational regist…
Endoskopiskas retrogrādas holangiopankreatogrāfijas un perkutānas transhepātiskas žulstsvadu stentēšanas metožu salīdzinājums onkoloģiskiem pacietiem…
2017
Problēmas aktualitāte. Katru gadu pacienti vēršas pie ārsta pēc palīdzības sakarā ar dzelti un dzeltes simptomiem, un nereti atklājas, ka pacientiem ir mehāniska žultsceļu obstrukcija sakarā ar ļaundabīgas masas palielināšanos vēdera dobumā. Lielākoties audzējs jau ir izplatījies, un radikāla operācija vairs nav iespējama. Šiem pacientiem, lai pagarinātu dzīvildzi un uzlabotu atlikušās dzīves kvalitāti, optimālākais risinājums ir paliatīva ārstēšana dzeltes mazināšanai. Darba mērķis. Aprakstīt un salīdzināt ERHP un PTHA stentēšanas metodes onkoloģiskiem pacientiem ar mehānisku dzelti, un izvērtēt, kura no metodēm pagarina pacienta dzīvildzi ar mazāku komplikāciju risku. Materiāli un metodes…