Search results for " Three-Dimensional"

showing 10 items of 323 documents

Long-term bony integration and resorption kinetics of a xenogeneic bone substitute after sinus floor augmentation: histomorphometric analyses of huma…

2013

In this case series, a systematic histomorphometric analysis of two human bone biopsy specimens was conducted 1 and 5 years after grafting with a xenogeneic bovine bone substitute material (BSM). While the 1-year specimen still showed extensive signs of an active desmal ossification, the specimen after 5 years mainly showed mature lamellar bone without bone turnover or remodeling. A completed bony integration without extensive resorption of the BSM particles could be detected. Altogether, a good integration in the bone with osteoconduction and a high biocompatibility was seen.

AdultMaleSinus Floor AugmentationBone RegenerationBone substituteBiopsyHuman boneDentistryBone MatrixSinus Floor AugmentationOsteocytesBone remodelingImaging Three-DimensionalOsseointegrationOsteogenesisBiopsymedicineMaxillaAnimalsHumansLongitudinal StudiesBone ResorptionMineralsBone Transplantationmedicine.diagnostic_testOssificationbusiness.industryDental Implantation EndosseousMembranes ArtificialX-Ray MicrotomographyMiddle AgedResorptionBovine boneBone SubstitutesPeriodonticsHeterograftsCattleFemaleCollagenOral Surgerymedicine.symptombusinessFollow-Up Studies
researchProduct

Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms

2008

Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…

AdultMalegenetic structuresinformation scienceAbsolute differenceStatistics NonparametricPulmonary function testingImaging Three-DimensionalHumansMedicinenatural sciencesRadiology Nuclear Medicine and imagingLung volumesAgedPhantoms Imagingbusiness.industryfood and beveragesSoft tissueReconstruction algorithmGeneral MedicineMiddle AgedRespiratory Function TestsPulmonary EmphysemaKernel (statistics)Radiographic Image Interpretation Computer-AssistedFemaleTomographyTomography X-Ray ComputedbusinessNuclear medicineAlgorithmQuantitative analysis (chemistry)AlgorithmsSoftwareEuropean Journal of Radiology
researchProduct

Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures

2013

The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…

AdultMalemedicine.medical_specialtyBone ScrewsComputed tomographyRadiation DosageFracture Fixation InternalIntraoperative PeriodImaging Three-DimensionalmedicineHumansFluoroscopyProspective StudiesAgedDigital radiographyAged 80 and overOsteosynthesismedicine.diagnostic_testbusiness.industryRadiusMiddle AgedRadiation exposureTreatment OutcomePlate osteosynthesisFluoroscopyFemaleSurgeryRadiologyCt imagingRadius FracturesTomography X-Ray ComputedbusinessBone PlatesJournal of Hand Surgery (European Volume)
researchProduct

Quantitative Assessment of Right Ventricular Volumes in Severe Chronic Thromboembolic Pulmonary Hypertension using Transthoracic Three-dimensional Ec…

2002

Evaluation of a three-dimensional reconstruction method to show the changes of right ventricular volume and systolic function when patients undergo pulmonary thromboendarterectomy for chronic thromboembolic pulmonary hypertension.In the examination of 11 patients (four female, seven male; age 56+/-10 years) before and after pulmonary thromboendarterectomy, end-diastolic and end-systolic right ventricular volumes were determined as a sum total of the calculated volumes of derived parallel slices of the right ventricle. Using a Tomtec workstation and a Vingmed CFM 800 echocardiography device, the acquired data were ECG-and respiration-triggered in the course of transthoracic examination, usin…

AdultMalemedicine.medical_specialtyCardiac VolumeHypertension Pulmonarymedicine.medical_treatmentEchocardiography Three-DimensionalDiastoleEndarterectomyPulmonary ArteryInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingSystoleAgedEjection fractionPulmonary thromboendarterectomyVentricular End-Systolic Volumebusiness.industryHemodynamicsGeneral MedicineMiddle Agedmedicine.anatomical_structureVentricleVentricular Function RightCardiologyVentricular volumeFemaleChronic thromboembolic pulmonary hypertensionRadiologyPulmonary EmbolismCardiology and Cardiovascular MedicinebusinessEuropean Journal of Echocardiography
researchProduct

Colorectal Polyps: Detection with Dark-Lumen MR Colonography versus Conventional Colonoscopy

2005

To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps.Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T …

AdultMalemedicine.medical_specialtyColonic PolypsContrast MediaRectumColonoscopySensitivity and SpecificityImaging Three-DimensionalMegluminePredictive Value of TestsImage Processing Computer-AssistedOrganometallic CompoundsmedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesProspective cohort studyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryMr colonographyMagnetic resonance imagingColonoscopyMiddle AgedMagnetic Resonance ImagingEndoscopyProne positionmedicine.anatomical_structurePredictive value of testsFemaleRadiologybusinessRadiology
researchProduct

Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus

2011

Objective: To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). Study Design: A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical…

AdultMalemedicine.medical_specialtyCone beam computed tomographyPanoramic radiographMaxillary sinusAdolescentRadiographyOdontologíaYoung AdultImaging Three-DimensionalRadiography PanoramicmedicineParanasal Sinus DiseasesHumansStatistical analysisChildGeneral Dentistrybusiness.industryMucous retention cystCystsClinical and Experimental dentistryCone-Beam Computed TomographyMaxillary SinusMiddle Agedrespiratory systemmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludrespiratory tract diseasesmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryFemaleResearch-ArticleRadiologybusiness
researchProduct

Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema.

2006

Abstract Purpose To assess the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level using CT and MRI in patients with emphysema. Material and methods Forty-five patients with severe emphysema (GOLD III and IV) underwent inspiratory 3D-HRCT and contrast-enhanced MR-perfusion (1.5T; 3.5 mm × 1.9 mm × 4 mm). 3D-HRCT data was analyzed using a software for detection and visualization of emphysema. Emphysema was categorized in four clusters with different volumes and presented as overlay on the CT. CT and lung perfusion were visually analyzed for three lobes on each side using a four-point-score to grade the abnormalities on CT (1: predominantly smal…

AdultMalemedicine.medical_specialtyContrast MediaSeverity of Illness IndexGold iiiImaging Three-DimensionalParenchymaImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingIn patientRespiratory systemLungAgedEmphysemaLungbusiness.industryRespiratory diseaseLung perfusionGeneral Medicinerespiratory systemMiddle Agedmedicine.diseaseImage EnhancementMagnetic Resonance Imagingrespiratory tract diseasesmedicine.anatomical_structureFemaleRadiologybusinessTomography X-Ray ComputedPerfusionEuropean journal of radiology
researchProduct

[Evaluation of three-dimensional endoanal endosonography of perianal fistulas and correlation with surgical findings].

2009

Abstract Objective This study aims to assess the accuracy of three-dimensional endoanal ultrasound (3D-US), two-dimensional ultrasound (2D-US) and physical examination (PE) for the diagnosis of perianal fistulas and correlate the results with intraoperative findings. Materials and methods A prospective, observational study with consecutive inclusion of patients was performed between December 2008 and August 2009. Twenty-nine patients diagnosed with a perianal fistula due to undergo surgery were included. All patients underwent PE, 2D-US and 3D-US, and the results were compared to intraoperative findings. The examinations were repeated with hydrogen peroxide instilled through the external op…

AdultMalemedicine.medical_specialtyFistulaConcordanceDiagnostic accuracyPhysical examinationSeverity of Illness IndexEndosonographyImaging Three-DimensionalPerianal fistulaEndoanal ultrasoundmedicineHumansRectal FistulaAgedmedicine.diagnostic_testbusiness.industryUltrasoundGeneral EngineeringTwo dimensional ultrasoundMiddle Agedmedicine.diseaseFemaleRadiologybusinessCirugia espanola
researchProduct

Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565

2005

Accurate assessment of left ventricular function by determining left ventricular volumes and ejection fraction is important in evaluating the prognoses of patients with heart failure. Two-dimensional (2D) echocardiography suffers from low correlation with reference methods like ventriculography. Three-dimensionally (3D) assessed data have been proved to have better conformity. Endocardial border delineation remains a problem, however, especially in patients with suboptimal recordings. Few data exist on 3D-echocardiographic volumetry with ultrasound contrast agents (UCAs). We evaluated the second-generation UCA LK565 for its boundary-tracing capacities in freehand 3D echocardiography in a ph…

AdultMalemedicine.medical_specialtyHeart VentriclesDiastoleContrast MediaImaging Three-DimensionalInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingSystoleEndocardiumAgedUltrasonographyHeart FailureAspartic AcidEjection fractionbusiness.industryUltrasoundStroke VolumeGeneral MedicineStroke volumeMiddle Agedmedicine.diseaseHeart failureCardiologyFeasibility StudiesEnd-diastolic volumeFemaleCardiology and Cardiovascular MedicinebusinessEuropean Journal of Echocardiography
researchProduct

3D echocardiographic reference ranges for normal left ventricular volumes and strain: results from the EACVI NORRE study

2017

International audience; Aim: To obtain the normal ranges for 3D echocardiography (3DE) measurement of left ventricular (LV) volumes, function, and strain from a large group of healthy volunteers. Methods and results: A total of 440 (mean age: 45 ± 13 years) out of the 734 healthy subjects enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study had good-quality 3DE data sets that have been analysed with a vendor-independent software package allowing homogeneous measurements regardless of the echocardiographic machine used to acquire the data sets. Upper limits of LV end-diastolic and end-systolic volumes were larger in men (97 and 42 mL/m2)…

AdultMalemedicine.medical_specialtyLongitudinal strainadult echocardiographydeformation imagingHeart VentriclesCardiac VolumeDiastoleEchocardiography Three-Dimensional030204 cardiovascular system & hematologyVentricular Function LeftHeart VentricleReference values03 medical and health sciencesYoung Adultleft ventricular function0302 clinical medicineInternal medicineHealthy volunteersthree-dimensional echocardiographyMedicineCircumferential strainHumansRadiology Nuclear Medicine and imagingReference Value030212 general & internal medicineSystoleAgedEjection fractionStrain (chemistry)business.industryGeneral MedicineMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREMiddle AgedHealthy VolunteerHealthy Volunteers3. Good healthRadiology Nuclear Medicine and imagingReference valuesCardiologyFemale[SDV.IB]Life Sciences [q-bio]/BioengineeringbusinessCardiology and Cardiovascular MedicineHuman
researchProduct