Characterisation of focal liver lesions undetermined at grey-scale US: contrast-enhanced US versus 64-row MDCT and MRI with liver-specific contrast a…
2010
The aim of this study was to assess the role of contrast-enhanced ultrasonography (CEUS) in the characterisation of focal liver lesions in comparison with multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) with liver-specific contrast agent.One hundred and eighty-seven focal liver lesions, 91 malignant and 96 benign (mean size 3.2 cm) - proved by biopsy (n=12), histology (n=4), MDCT (n=108), MRI (n=44) MDCT/MRI (n=19) - in 159 patients were studied by CEUS. Two expert radiologists consensually evaluated the contrast-enhancement patterns at CEUS. For each lesion, they assessed: (a) nature (benign, malignant, not assessable), (b) specific diagnosis and (c) need for …
Color doppler ultrasonography of soft-tissue masses
1998
Purpose: To evaluate the capability of color Doppler ultrasonography to differentiate between benign and malignant soft-tissue tumors. Material and Methods: We reviewed the ultrasonographic (US) and color Doppler (CD) findings in 46 consecutive patients with a palpable periskeletal mass. The presence of 3 or more vascular hila and of tortuous and irregular internal vessels within the lesions was considered an indication of malignancy. The CD diagnosis was compared with that obtained at US alone. Results: The sensitivity and specificity of CD were respectively 85% and 92%; these values were higher than those obtained at US alone, respectively 75% and 50%. Arteriovenous malformations present…
Hepatic focal nodular hyperplasia: contrast-enhanced ultrasound findings with emphasis on lesion size, depth and liver echogenicity
2010
To correlate contrast-enhanced ultrasound (CEUS) findings of hepatic focal nodular hyperplasia (FNH) with lesion size, depth and liver echogenicity and to compare CEUS with baseline US. Two radiologists evaluated baseline US and CEUS examinations of 92 FNHs (mean size: 3.1 +/- 1.7 cm) in 71 patients (59 women and 12 men) to detect the "spoke-wheel" sign, central scar and feeding vessel. The FNHs were grouped and analysed by dimension, depth and liver echogenicity. At least one sign could be detected at CEUS in 27 out of 36 (75%) FNHs larger than 3 cm and in 17 out of 56 (30%) FNH measuring 3 cm or less (p 0.05) as well as between CEUS or baseline US/CD with regard to lesion size, depth or l…
Indeterminate focal liver lesions incidentally discovered at gray-scale US: role of contrast-enhanced sonography.
2011
OBJECTIVES: to assess the role of contrast-enhanced ultrasound (CEUS) in the characterization of focal liver lesions (FLLs) incidentally discovered but indeterminate at gray-scale ultrasound (US). MATERIALS AND METHODS: one hundred forty-two consecutive patients with 174 FLLs (169 benign and 5 malignant) incidentally discovered but indeterminate at gray-scale US, underwent CEUS after the administration of SonoVue. Two readers independently reviewed CEUS scans and: (1) classified each lesion as malignant or benign on a 5-point scale of confidence by means of definite diagnostic criteria; (2) provided if possible a specific diagnosis; (3) were requested if further imaging was needed for lesio…
Study of neurinomas with ultrasound contrast media: review of a case series to identify characteristic imaging patterns
2011
The aim of this study was to evaluate whether there exists a characteristic distribution pattern of vessels within neurinomas that may be used to characterise this type of lesion by employing a contrast-specific ultrasound technique.Between January 2003 and May 2010, 66 suspected neurinomas were evaluated according to their sonographic features (solid fusiform mass with well-defined margins located in direct continuity with the nerve that was not always discernible and heterogeneous as a result of the presence of small cystic areas or calcifications). The lesions were examined using a sonographic contrast medium consisting of sulphur hexafluoride microbubbles and equipment with dedicated co…
Contrast-enhanced ultrasonography: usefulness in the assessment of postoperative recurrence of Crohn's disease.
2013
Abstract Aim The aim of this study was to assess whether the contrast-enhanced ultrasonography (CEUS) can increase the value of the ultrasonography in the study of postoperative recurrence of Crohn's disease (CD). Materials and methods 60 patients with CD who had previously undergone ileocolic resection underwent prospectively both CEUS and colonoscopy within a 3-day period. The sonographic examination included evaluation of bowel wall thickness, transmural complications, colour Doppler grade and contrast-enhanced US. In addition a sonographic score was established. The capacity of CEUS to diagnose endoscopic recurrence, as well as its severity, was assessed by calculating the sensitivity, …
Evaluation of posttreatment response of hepatocellular carcinoma: comparison of ultrasonography with second-generation ultrasound contrast agent and …
2010
We evaluated the ability of one-month follow-up contrast-enhanced ultrasound (CEUS) with second-generation contrast agent in monitoring radio frequency ablation (RFA) and transcatheter arterial chemoembolization (TACE) treatments of hepatocellular carcinoma (HCC). One-hundred forty-eight HCCs were studied using CEUS: 110 nodules were treated with RFA [41/110 RFA were performed using a pretreatment and an immediate postablation evaluation using CEUS (group 1); 69/110 using only US guidance (group 2)] and 38 nodules treated with TACE. For statistical analysis, McNemar test was used. Overall complete response was observed in 107/148 nodules (92/110 treated with RFA and 15/38 with TACE). A bett…
Suspicious liver nodule in chronic liver disease: Usefulness of a second biopsy
2018
International audience; Purpose: To assess the usefulness of a second biopsy when the first one was inconclusive in patients with a liver nodule found during the follow-up for chronic liver disease.Materials and methods: Among 381 patients (544 nodules) included in a prospective study designed to evaluate the accuracy of imaging for the diagnosis of small hepatocellular carcinoma (HCC) in chronic liver disease, 254 nodules were biopsied. The following histological results were considered as conclusive: HCC, dysplastic or regenerative nodule, and other identified tumors (benign or malignant). For nodules with inconclusive results (e.g. fibrosis or no definite focal lesion), a second biopsy w…
Real-time ultrasound-guided infraclavicular axillary vein cannulation: A prospective study in mechanically ventilated critically ill patients.
2016
Purpose: The main purpose of this study was to define the venipuncture and catheterization success rates and early mechanical complication rates of ultrasound-guided infraclavicular axillary vein cannulation. Materials and methods: We performed in-plane, real-time, ultrasound-guided infraclavicular axillary vein catheterizations under emergency and nonemergency conditions in mechanically ventilated, critically ill patients. Results: We performed 202 cannulation attempts. One hundred and twenty-six procedures (62.4%) were performed under emergency conditions. The puncture of the axillary vein was successful in 98.5% of patients, and the entire procedure success rate was 95.1% (95% confidence…
The intravascular ultrasound morphometry of iliac veins in subjects without severe chronic venous insufficiency and its implications for treatment in…
2019
Objectives The purpose of this study is to report the intravascular ultrasound morphometry of iliac veins and its relation to demographic and anthropometric factors in subjects without chronic venous insufficiency. Methods Thirty-three patients, without chronic venous insufficiency – qualified to great saphenous vein stripping due to unilateral, primary varicose veins – participated in the study. During the surgery, left and right external iliac veins, common iliac veins and inferior vena cava were interrogated with intravascular ultrasound. The morphometric analysis included measurement of a cross-sectional area at normal, non-stenosed vein segments (ref-CSA) and at the point of the most p…