Search results for " Ultrasonic"
showing 10 items of 344 documents
Thickness sensitivity of ultrasound velocity in long bone phantoms
2004
One approach to bone disease diagnosis such as osteoporosis is to measure the velocity of ultrasound propagating axially along long bones. In this study, the variation in velocity as a function of radial position was assessed using two polyvinyl chloride (PVC) bone phantoms with cross-sectional geometry similar to the human tibia but differing in medullary cavity diameter. Two ultrasonometers were used: these were a commercial device operating at a relatively high frequency (HF) of 1.25 MHz and a prototype low frequency (LF) device operating at approximately 200 kHz. The LF measurements showed a larger variation with radial position, with changes in velocity of up to 20% occurring around th…
Improvement of oxidation resistance of polymer-based nanocomposites through sonication of carbonaceous nanoparticles
2020
Abstract The work aim is focused on two different aspects: first, the investigation of the effect of extended ultra-sound-assisted treatment (us) of carbonaceous nanoparticles, such as carbon nanotubes (CNTs) and carbon black (CB), on their radical scavenging activity, and second, the investigation of the oxidative resistance of polymer-based nanocomposites, containing us-treated CNTs and CB. Particularly, the CNTs and CB have been subjected to us sonication for different time intervals and the performed analysis reveals that both kinds of nanoparticles show decreased average hydrodynamic diameters and large content of surface defects. Really, the increased content of CNTs and CB defects, a…
Cluster issue on Heusler compounds and devices
2009
Modeling and Experimental Verification of Ultrasound Transmission in Electro Insulation Oil
2012
A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside t…
Swift-ion-induced hardening and reduction of dislocation mobility in LiF crystals
2008
Ion-induced change in Vickers hardness and arm length of dislocation rosettes created by indentation on the (1 0 0) face of LiF crystals was studied. The irradiations were performed using swift U, Bi and Ni ions with a specific energy of 11 MeV per nucleon at fluences between 106 and 1013 ions cm−2. Remarkable effects of the ion-induced hardening and reduction of dislocation arm length were observed above the threshold fluences of about 109–1010 ions cm−2 and 106–107 ions cm−2, respectively. The products of track core damage and aggregates of single defects in the halo of overlapping tracks are responsible for the effects. The results are analysed using the Orowan's model of dislocation imp…
Exchange bias in epitaxial Mn2Au (0 0 1)/Fe (0 0 1) bilayers
2019
Grain size effect and local disorder in polycrystalline relaxors via scanning probe microscopy
2007
Local piezoresponse of individual grains in polycrystalline Pb0.9125La0.0975(Zr0.65Ti0.35)0.976O3 (PLZT 9.75/65/35) relaxor ceramics is studied using the scanning probe microscopy (SPM) technique. The observed piezoelectric contrast consisting of irregular (labyrinth-type) polarization patterns is attributed to the compositional disorder and consequent charge imbalance caused by high La concentration. A measure of this disorder, the polarization correlation length ξ, is directly determined using an autocorrelation analysis function implemented in the SPM software. The analysis of the obtained images shows that ξ taken at the scale ~200 nm varies as a function of the position inside the grai…
Epitaxial Mn2Au thin films for antiferromagnetic spintronics
2015
Mn2Au is one of the few candidate materials for antiferromagnetic spintronics requiring ordered metals with a high Neel-temperature and strong spin–orbit coupling. We report the preparation of epitaxial Mn2Au thin films by rf-sputtering. Structural characterization by x-ray and electron diffraction demonstrates a high degree of atomic order and the temperature dependence of the resistivity is typical for a good metal. The magnetic properties of the samples are studied by the investigation of Mn2Au/Fe bilayers. Exchange bias effects are observed, which present strong evidence for antiferromagnetic order in the Mn2Au thin films. Small domains of 500 nm are visualized in the exchange coupled F…
Influence of plasma chemistry on impurity incorporation in AlN prepared by plasma enhanced atomic layer deposition
2013
Impurities in aluminum nitride films prepared by plasma enhanced atomic layer deposition using NH3-, N2/H2- and N2-based plasmas are investigated by combining time-of-flight elastic recoil detection analysis (ERDA) and Fourier transform infrared spectroscopy. Different atomistic growth mechanisms are found to exist between the plasma chemistries. N2-plasma is shown as not suitable for the low-temperature deposition of AlN. Films deposited by NH3- and N2/H2-based processes are nitrogen rich and heavily hydrogenated. Carbon impurities exist at higher concentrations for the N2/H2-processes. The discovery of nitrile groups in the films indicates that carbon impurities can be partially attribute…
VUV irradiance measurement of a 2.45 GHz microwave-driven hydrogen discharge
2015
Absolute values of VUV-emission of a 2.45 GHz microwave-driven hydrogen discharge are reported. The measurements were performed with a robust and straightforward method based on a photodiode and optical filters. It was found that the volumetric photon emission rate in the VUV-range (80-250 nm) is $10^{16}$-$10^{17}$ 1/cm$^3$s, which corresponds to approximately 8% dissipation of injected microwave power by VUV photon emission. The volumetric emission of characteristic emission bands was utilized to diagnostics of molecular plasma processes including volumetric rates of ionization, dissociation and excitation to high vibrational levels and metastable states. The estimated reaction rates impl…