Search results for " Ultrasonic"
showing 10 items of 344 documents
In vitro comparison of passive and continuous ultrasonic irrigation in curved root canals
2016
BACKGROUND The efficacy of endodontic irrigation procedures can be compromised by the complexity of the root canal system. Delivering irrigants to the apical third of curved canals presents a particular challenge to endodontists. This study compared the effects of two ultrasonic irrigation techniques on the penetration of sodium hypochlorite into the main canal and simulated lateral canals of curved roots in extracted teeth. MATERIAL AND METHODS Two sets of simulated lateral canals were created at 2, 4, and 6 mm from the working length in 60 single-rooted teeth (6 canals/tooth, n = 360 canals). The teeth were randomly divided into three experimental irrigation groups: group 1 (n = 20), posi…
High-Intensity Focused Ultrasound- and Radiation Therapy-Induced Immuno-modulation: Comparison and Potential Opportunities
2017
In recent years, high-intensity focused ultrasound (HIFU) has emerged as a new and promising non-invasive and non-ionizing ablative technique for the treatment of localized solid tumors. Extensive pre-clinical and clinical studies have evidenced that, in addition to direct destruction of the primary tumor, HIFU-thermoablation may elicit long-term systemic host anti-tumor immunity. In particular, an important consequence of HIFU treatment includes the release of tumor-associated antigens (TAAs), the secretion of immuno-suppressing factors by cancer cells and the induction of cytotoxic T lymphocyte (CTL) activity. Radiation therapy (RT) is the main treatment modality used for many types of tu…
INVERSION TESTS ON ULTRASONIC TOMOGRAPHY DATA
2010
3D Ultrasonic Tomography for non-destructive test and for diagnostic study works of art is a rather established methodology. This method allow us to locate, within the volume of work of art, areas of structural non homogeneities, areas of decay, fracture or damaged. This work wants to present some tests carried out to optimize these parameters in order to obtain a better anomaly image resolution for the case history presented. The optimization of these parameters allows locating structural non homogeneity areas, fractures or damages, within the volume, according to shape and type of the investigated anomalies.
On the variations of acoustic absorption peak with particle velocity in micro-perforated panels at high level of excitation.
2010
The acoustic behavior of micro-perforated panels (MPP) is studied theoretically and experimentally at high level of pressure excitation. A model based on Forcheimer's regime of flow velocity in the perforations is proposed. This model is valid at relatively high Reynolds numbers and low Mach numbers. The experimental method consists in measuring the acoustical pressure at three different positions in an impedance tube, the two measurement positions usually considered in an impedance tube and one measurement in the vicinity of the rear surface of the MPP. The impedance tube is equipped with a pressure driver instead of the usual loudspeaker and capable of delivering a high sound pressure lev…
Acoustic characterization of Silica aerogel clamped plates for perfect absorption purpose
2017
International audience; Silica aerogel has been widely studied as bulk material for its extremely low density and thermal conductivity. Plates or membranes made of this extremely soft materials exhibits interesting properties for sound absorption. A novel signal processing method for the characterization of an acoustic metamaterial made of silica aerogel clamped plates is presented. The acoustic impedance of a silica aerogel clamped plate is derived from the elastic theory for the flexural waves, while the transfer matrix method is used to model reflection and transmission coefficients of a single plate. Experimental results are obtained by using an acoustic impedance tube. The difference b…
Experimental investigation of holes interaction effect on the sound absorption coefficient of micro-perforated panels under high and medium sound lev…
2011
Abstract This paper experimentally investigates the holes interaction effect on the sound absorption coefficient of micro-perforated panels under high and medium sound levels. The theoretical formulations are based on a semi-empirical approach and the use of Fok’s function to model the acoustic surface impedance. For the high sound level regime, an empirical power law involving three coefficients is adapted. It is shown theoretically and experimentally that these coefficients can lead to optimized absorption performance and particularly, a formula relating the critical Reynolds number (Reynolds number value after which the absorption coefficient decreases with the increase of sound level) a…
Acoustic characterization of the ancient theatre at Syracuse
2008
The ancient theatre at Syracuse, the largest open air theatre in Sicily, experienced many structural changes along its history. Today its very renowned drama festival attracts visitors from all the world that fill the entire cavea: customized seats accomodation and a prominent stage play an important role in the theatre acoustics. Because no data were available in literature on its acoustical perfomance a measurement session was carried out by our team in the framework of a wide research project on ancient theatres acoustics in the modern use. From data recorded "room criteria" parameters have been evaluated together with spectral analysis in order to gain a deeper information on the acoust…
Wooden panel paintings investigation: An air-coupled ultrasonic imaging approach
2007
In this paper, a method for the study of wooden panel paintings using air-coupled acoustical imaging is presented. In order to evaluate the advantages of the technique, several samples were made to mimic panel paintings along with their typical defects. These specimens were tested by means of both single-sided and through-transmission techniques using planar transducers. Image data were processed by means of a two-dimensional (2-D)-fast Fourier transform-based algorithm to increase the S/N ratio and 2-D representations (C-scans) were generated. The simulated defects were imaged using both configurations. Investigations were undertaken on four antique paintings from a private collection. The…
Femtosecond up-conversion technique for probing the charge transfer in a P3HT : PCBM blend via photoluminescence quenching
2009
We report on an experimental study of the charge transfer dynamics in a P3HT : PCBM blend by means of a femtosecond fluorescence up-conversion technique. Using two-photon excitation we probe the exciton dynamics in P3HT and a P3HT : PCBM blend with a weight ratio of 1 : 1 at excitation densities of up to 6 × 1018 cm−3. In both samples we find strongly nonexponential decay traces compatible with (i) diffusion-limited exciton–exciton annihilation and (ii) diffusion-limited donor–acceptor charge transfer in the polymer blend. Additionally, our results indicate that in the P3HT : PCBM blend about 50% of the photogenerated excitons undergo a prompt charge transfer process on a time scale of abou…
Calculations of high-power production target and beamdump for the GSI future Super-FRS for a fast extraction scheme at the FAIR Facility
2005
A superconducting fragment separator (Super-FRS) is being designed for the production and separation of radioactive isotopes at the future FAIR (Facility for Antiprotons and Ion Research) facility at Darmstadt. This paper discusses various aspects and requirements for the high-power production target that will be used in the Super-FRS experiments. The production target must survive over an extended period of time as it will be used during the course of many experiments. The specific power deposited by the high intensity beam that will be generated at the future FAIR facility will be high enough to destroy the target in most of the cases as a result of a single shot from the new heavy ion sy…