Search results for " Vent"
showing 10 items of 1372 documents
TUMORS OF THE LATERAL AND THIRD VENTRICLE
2005
Abstract OBJECTIVE: Intraventricular tumors usually are managed by approaches and microsurgical techniques that need retraction and dissection of important brain structures. Minimally invasive endoscopic procedures achieve a remarkable alternative to conventional microneurosurgical techniques. Endoscope-assisted microneurosurgery may be a minimally invasive technique with maximally effective treatment. Using the keyhole concept for planning the surgical strategy, the reduction of the brain retraction is achieved, which is one of the main benefits of this technique. METHODS: We treated 35 patients (16 female patients and 19 male patients) with tumors in the lateral (n = 8) and the third (n =…
Brain-core temperature of patients before and after orthotopic liver transplantation assessed by DWI thermometry
2018
To assess brain-core temperature of end-stage liver disease patients undergoing orthotopic liver transplantation (OLT) using a temperature measurement technique based on the apparent diffusion coefficient of the cerebrospinal fluid in the lateral ventricles. The study group was composed of 19 patients with a model for end-stage liver disease (MELD) score of 23.7 who underwent MR imaging before and after OLT. MR imaging studies were performed with a 1.5T MR scanner. Brain-core temperature (T: °C) was calculated using the following equation from the apparent diffusion coefficient (D) of the cerebrospinal fluid in the lateral ventricles: $$T = {{2256.74} \mathord{\left/ {\vphantom {{2256.74} {…
Acute performance evaluation of a new ventricular automatic capture algorithm
2006
Aims This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors. Methods and results During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA™ pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance. Loss-of-capture events (two consecutive non-captured beats without backup pacing) were used to assess safety. Data of 53 patients…
High-frequency oscillatory ventilation and an interventional lung assist device to treat hypoxaemia and hypercapnia
2004
A male patient accidentally aspirated paraffin oil when performing as a fire-eater. Severe acute respiratory distress syndrome ( P a 2 / F 2 ratio 10.7 kPa) developed within 24 h. Conventional pressure-controlled ventilation (PCV) with high airway pressures and low tidal volumes failed to improve oxygenation. Hypercapnia ( P a 2 12 kPa) with severe acidosis (pH<7.20) ensued. Treatment with high-frequency oscillatory ventilation (HFOV) and a higher adjusted airway pressure (35 cm H2O) improved the P a 2 / F 2 ratio within 1 h from 10.7 to 22.9 kPa, but the hypercapnia and acidosis continued. Stepwise reduction of the mean airway pressure (26 cm H2O), and oscillating frequencies (3.5 Hz), as …
Human Dental Pulp Stem Cells Improve Left Ventricular Function, Induce Angiogenesis, and Reduce Infarct Size in Rats with Acute Myocardial Infarction
2008
Abstract Human dental pulp contains precursor cells termed dental pulp stem cells (DPSC) that show self-renewal and multilineage differentiation and also secrete multiple proangiogenic and antiapoptotic factors. To examine whether these cells could have therapeutic potential in the repair of myocardial infarction (MI), DPSC were infected with a retrovirus encoding the green fluorescent protein (GFP) and expanded ex vivo. Seven days after induction of myocardial infarction by coronary artery ligation, 1.5 × 106 GFP-DPSC were injected intramyocardially in nude rats. At 4 weeks, cell-treated animals showed an improvement in cardiac function, observed by percentage changes in anterior wall thic…
Magnetic resonance imaging in primary cerebral neuroblastoma
1989
Cognitive impairment in multiple sclerosis can be predicted by imaging early in the disease.
2008
Background: Cognitive impairment is common in multiple sclerosis (MS) and adds significantly to the burden of the disease. The ability to predict future cognitive impairment from imaging obtained at disease onset has not been investigated. Methods: 62 patients imaged within 3 months of a clinically isolated syndrome were assessed neuropsychologically 7 years later. Baseline and periodic MRI measures of lesions, atrophy and normal-appearing white and grey matter were regressed against neuropsychological scores to explore the best predictors of cognitive outcome. Results: 28 patients had developed clinically definite MS at follow-up and a further nine met revised McDonald criteria for MS. Def…
Influence of ultra-long-term fatigue on the oxygen cost of two types of locomotion.
2000
The aim of this study was to examine the effects of fatigue induced by a 65-km ultramarathon on the oxygen cost of running (Cr) and cycling (Ccycl). The day before and immediately after the race, a group of nine well-trained male subjects performed two sub-maximal 4-min exercise bouts: one cycling at a power corresponding to 1.5 W · kg−1 body mass on an electromagnetically braked ergometer, and one running at 11 km · h−1 on a flat asphalt roadway. Before oxygen cost determinations, the subjects performed 12 “ankle” jumps at a given frequency that was fixed by an electronic metronome (2.5 Hz). From the non-fatigued to the fatigued condition, there was a significant increase in minute ventila…
Baroreflex control of heart rate during sleep in severe obstructive sleep apnoea: effects of acute CPAP
2006
Baroreflex control of heart rate during sleep (baroreflex sensitivity; BRS) has been shown to be depressed in obstructive sleep apnoea (OSA), and improved after treatment with continuous positive airway pressure (CPAP). Whether CPAP also acutely affects BRS during sleep in uncomplicated severe OSA is still debatable. Blood pressure was monitored during nocturnal polysomnography in 18 patients at baseline and during first-time CPAP application. Spontaneous BRS was analysed by the sequence method, and estimated as the mean sequence slope. CPAP did not acutely affect mean blood pressure or heart rate but decreased cardiovascular variability during sleep. Mean BRS increased slightly during CPAP…
Exercise intolerance at high altitude (5050 m): critical power and W'.
2011
Abstract The relationship between work rate (WR) and its tolerable duration (tLIM) has not been investigated at high altitude (HA). At HA (5050 m) and at sea level (SL), six subjects therefore performed symptom-limited cycle-ergometry: an incremental test (IET) and three constant-WR tests (% of IET WRmax, HA and SL respectively: WR1 70 ± 8%, 74 ± 7%; WR2 86 ± 14%, 88 ± 10%; WR3 105 ± 13%, 104 ± 9%). The power asymptote (CP) and curvature constant (W′) of the hyperbolic WR–tLIM relationship were reduced at HA compared to SL (CP: 81 ± 21 vs. 123 ± 38 W; W′: 7.2 ± 2.9 vs. 13.1 ± 4.3 kJ). HA breathing reserve (estimated maximum voluntary ventilation minus end-exercise ventilation) was also comp…