Search results for " Vessel"
showing 10 items of 625 documents
High-Frequency rotablation of occluded coronary artery during heart catheterization
1989
High-frequency rotation atherectomy of an occluded left circumflex coronary artery was performed in a 45-year-old man. Over a 0.009 inch flexible tip steel wire a diamond-coated brass burr fasten to a flexible drive shaft that rotates and tracks was advanced. The drive shaft was connected to a turbine and driven by compressed air with 150,000 rpm. After rotablation of the posterior lateral branch over 3 cm with a 1.5 mm burr and rotablation with a 1.75 mm burr of the posterior branch of the left circumflex coronary artery the vessel was reopened with a smooth surface without perforation and dissection. 24 h control and 6 mo control revealed an open coronary vessel. High frequency rotating c…
Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary a…
2008
Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…
Clinical relevance of myocardial bridging detected by coronary CT angiography in patients with atypical chest pain
2019
Role of the Endothelium in the Relaxation Induced by Propofol and Thiopental in Isolated Arteries from Man
1997
Abstract Induction of anaesthesia with intravenous propofol and thiopental is often accompanied by hypotension. This study evaluates whether propofol and thiopental induce relaxation of isolated arteries from man and whether this effect is modulated by the endothelium. Mesenteric artery rings (with and without endothelium) from 12 patients were placed in organ baths and precontracted with phenylephrine before addition of propofol (10−3 M) or thiopental (10−3 M). Relaxation induced by propofol and thiopental was evaluated for rings with intact endothelium in the presence of the nitric oxide synthase inhibitor NG-nitro-l-arginine methyl ester (l-NAME; 10−4 M) or the cyclooxygenase inhibitor i…
Functional and Prognostic Implications of the Main Pulmonary ArteryDiameter to Aorta Diameter Ratio from Chest Computed Tomography inKorean COPD Pati…
2016
Background The ratio of the diameter of the main pulmonary artery (mPA) to the diameter of the aorta (Ao) on chest computed tomography is associated with diverse clinical conditions. Herein, we determined the functional and prognostic implications of the mPA/Ao ratio in Korean chronic obstructive pulmonary disease (COPD) patients. Methods The study population comprised 226 chronic obstructive pulmonary disease patients from the Korean Obstructive Lung Disease cohort who underwent chest computed tomography. We analyzed the relationships between the clinical characteristics, including pulmonary function, echocardiography findings, St. George's Respiratory Questionnaire, 6-minute walking (6MW)…
Automatic or manual arterial path for the ankle-brachial differences pulse wave velocity
2018
Este artículo se encuentra disponible en la página web de la revista en la siguiente URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0206434 An automated method for measuring arterial path length with devices that determine pulse wave velocity (PWV) in peripheral arteries is frequently applied. We aimed to compare arterial path length measurements based on mathematical height-based formulas with those measured manually and to assess whether the ankle-brachial difference (abD-PWV) measured with the VOPITB device is comparable to that obtained by manual measurements. In 245 patients, a metric measuring tape was used to determine the arterial path length from the suprast…
Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography
2005
PURPOSE: To assess the variability in attenuation of coronary plaques with multislice CT-angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. MATERIALS AND METHODS: MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1/80). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f-medium, and B60f-sharp). Each scan was scored for the pre…
Preliminary evaluation of near-infrared vein visualization technology in the screening of palatal blood vessels.
2018
Background Avoidance from palatal blood vessel rupture is a major concern during the palatal soft tissue graft surgery. There is no defined chair-side and case-specific palatal blood vessel detection approach to facilitate the harvesting process. The objective of this pilot study is to assess the feasibility of a near-infrared vein visualization system in the screening process of palatal blood vessels. Material and Methods An extraoral vein visualization device (AccuVein AV400) was applied to a total of 304 hemi-maxilla of 152 individuals by two blind examiners. The study groups were classified according to their maximum inter-incisal measurements. The distances between the coronal border o…
RELATIONSHIP BETWEEN THEOPHYLLINE UPTAKE AND INOTROPIC EFFECT IN THE GUINEA-PIG HEART
1974
1 The time course of the positive inotropic effect of theophylline was compared with the time course of the uptake and release of [(3)H]-theophylline in guinea-pig isolated, electrically driven hearts perfused by the Langendorff method.2 Formation of theophylline metabolites could not be detected under the experimental conditions used.3 Theophylline entered myocardial tissue very rapidly in two different phases. The first process (half-time 21 s) amounted to 93% and the second (half-time 5 min 50 s) to 7% of the total uptake. The development of the positive inotropic effect of theophylline was about four times faster than even the rapid component of the uptake of the drug into the myocardiu…
Long-Term Results After Repair of Type A Acute Aortic Dissection According to False Lumen Patency
2009
Background Late survival and freedom from retreatment on the descending aorta was evaluated after ascending aortic repair for type A acute aortic dissection (TAAAD). Methods Between March 1992 and January 2006, 189 TAAAD patients (mean age, 52 ± 11; range, 17 to 83 years) were included; of these, 58 had a patent false lumen, and 49 had Marfan syndrome. The descending aorta was evaluated postoperatively with computed tomography (CT). Late outcomes were assessed by Cox regression analysis and actuarial survival and freedom from retreatment by the Kaplan-Meier method. Mean follow-up was 88 ± 44 months. Results There were 38 (20%) late deaths. At 10 years, survival was 89.8% ± 2.1% for patients…