Search results for " and agriculture"
showing 10 items of 933 documents
Traction test of temporary dental cements
2017
Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear…
Bioactividad del polimetilmetacrilato (cemento óseo) modificado
1988
The polymethylmetacrylate bone cement reaction in clinical practice is conditioned in part by its biological activity and ageing An in vivo and in vitro experimental study was conducted to elucidate the possible implications of some bone cements mineral additives on bioactivity behaviour. ' Some substances (as quartz and wollastonite) can develop bioactivity phenomena when added to PMMA cement and may enhance its biological compatibility.
Ritz Solution for Transient Analysis of Variable-Stiffness Shell Structures
2020
The dynamic response of thin-walled structures is driven by mass and stiffness distribution. As such, variable-stiffness (VS) composites offer opportunities to tune structural dynamic responses. To this extent, efficient analysis tools become increasingly important for structural analysis and design purposes. In this work, an efficient and versatile Ritz method for free vibrations and linear transient analysis of VS doubly curved shell structures is presented. VS shell structures are modeled as an assembly of shell-like domains. The shell kinematics is based on the first-order shear deformation theory, and no further assumption is made on the shallowness or on the thinness of the structure.…
Stiffness and Reinforcement Effect of electrical Resistance Strain Gauges
2007
: The increasing use of low-modulus materials, on which the reinforcement effect of the electrical resistance strain gauge is not negligible, has re-opened the research interest into this issue. This study deals with the evaluation of stiffness, and of the strain gauge Young's modulus involved in the estimation of both the global and the local reinforcement effect; the relationship between the strain gauge stiffness and the local reinforcement effect is also analysed. In particular, the experimental technique used to determine the stiffness of some commercial strain gauges is described. The results show that the strain gauge stiffness alone does not permit an accurate evaluation of the loc…
Improving the cementation of the tibial component in knee arthroplasty : a study of four techniques in the cadaver.
2021
Aims The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. Methods In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and mea…
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: …
2020
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
CMC is more than a measure of corticospinal tract integrity in acute stroke patients
2021
In healthy subjects, motor cortex activity and electromyographic (EMG) signals from contracting contralateral muscle show coherence in the beta (15-30 Hz) range. Corticomuscular coherence (CMC) is considered a sign of functional coupling between muscle and brain. Based on prior studies, CMC is altered in stroke, but functional significance of this finding has remained unclear. Here, we examined CMC in acute stroke patients and correlated the results with clinical outcome measures and corticospinal tract (CST) integrity estimated with diffusion tensor imaging (DTI). During isometric contraction of the extensor carpi radialis muscle, EMG and magnetoencephalographic oscillatory signals were re…
In Vitro Study on Bone Heating during Drilling of the Implant Site: Material, Design and Wear of the Surgical Drill
2020
Objective: An in vitro study was made to compare mean thermal variation according to the material, design and wear of the surgical drills used during dental implant site preparation. Material and methods: Three study groups (stainless steel drills with straight blades
Large-scale radiation manufacturing of hierarchically assembled nanogels
2012
Nanogels (NGs), or small particles formed by physically or chemically crosslinked polymer networks, represent a niche in the development of "smart" nanoparticles for drug delivery and diagnostics. They offer unique advantages over other systems, including a large and flexible surface for multivalent bio-conjugation; an internal 3D aqueous environment for incorporation and protection of (bio)molecular drugs; the possibility to entrap active metal or mineral cores for imaging or phototherapeutic purposes; stimuli-responsiveness to achieve temporal and/or site control of the release function and biocompatibility. The availability of inexpensive and robust preparation methodologies is at the ba…
Optical properties and photosensitivity of vacuum synthesized Ge-doped sol-gel amorphous SiO/sub 2/
2005
We report optical and electron paramagnetic resonance investigations of gamma ray irradiation effects in sol-gel Ge-doped amorphous SiO/sub 2/. The studied materials have Ge-doping levels up to 10/sup 4/ molar part per million and were densified by two routes differing for the atmosphere: O/sub 2/+N/sub 2/ or vacuum. The obtained results evidence that irradiation affects matrix sites inducing paramagnetic defects. Furthermore, the comparison between the two densification procedures shows that vacuum atmosphere induces higher radiation sensitivity.