Frontal Electroencephalogram Alpha Asymmetry during Mental Stress Related to Workplace Noise

2021

This study aims to investigate the effects of workplace noise on neural activity and alpha asymmetries of the prefrontal cortex (PFC) during mental stress conditions. Workplace noise exposure is a pervasive environmental pollutant and is negatively linked to cognitive effects and selective attention. Generally, the stress theory is assumed to underlie the impact of noise on health. Evidence for the impacts of workplace noise on mental stress is lacking. Fifteen healthy volunteer subjects performed the Montreal imaging stress task in quiet and noisy workplaces while their brain activity was recorded using electroencephalography. The salivary alpha-amylase (sAA) was measured before and immedi…

medicine.medical_specialtyBrain activity and meditationAlpha (ethology)ElectroencephalographyAudiologylcsh:Chemical technologyBiochemistryPrefrontal cortexArticle050105 experimental psychologyNoise stressAnalytical ChemistryTraitement du signal et de l'image [Informatique]Salivary alpha-amylase03 medical and health sciences0302 clinical medicine[INFO.INFO-TS]Computer Science [cs]/Signal and Image ProcessingStress (linguistics)medicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansImagerie médicale [Informatique]lcsh:TP1-1185Attention0501 psychology and cognitive sciencesElectrical and Electronic EngineeringWorkplacePrefrontal cortexEEG alpha-asymmetryInstrumentationmedicine.diagnostic_test05 social sciencesElectroencephalographyCognitionAtomic and Molecular Physics and OpticsElectroencephalogram (EEG)Frontal LobeAlpha RhythmNoiseQUIETPsychologyStress Psychological030217 neurology & neurosurgery
researchProduct

Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise

2021

A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant cha…

medicine.medical_specialtyContraction (grammar)HemodynamicsVasodilationThumb01 natural sciencesArticle010309 optics03 medical and health sciencesInternal medicine0103 physical sciencesOcclusionmedicine030304 developmental biology0303 health sciencesAbductor pollicis brevis musclebusiness.industryBlood flowLaser Doppler velocimetryAtomic and Molecular Physics and Opticsbody regionsmedicine.anatomical_structureCardiologybusinesshuman activitiesBiotechnologyBiomedical Optics Express
researchProduct

Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmissi…

2021

Running retraining programs focused on concurrent feedback of acceleration impacts have been demonstrated to be a good strategy to reduce running-related injuries (RRI), as well as to improve running economy and reduce acceleration impacts and injury running incidence. Traditionally, impacts have been registered by mean of accelerometers attached directly to the athletes, which is inaccessible to the entire population, because it requires laboratory conditions. This study investigated the validity and reliability of a new device integrated directly into the treadmill, compared to a traditional acceleration impact system. Thirty healthy athletes with no history of RRI were tested on two sepa…

medicine.medical_specialtyDidáctica de la Expresión CorporalComputer scienceAccelerationValidityInstrumented treadmillInstrumented treadmillAccelerometerlcsh:Chemical technologyBiochemistryArticleAnalytical ChemistryRunning03 medical and health sciencesAcceleration0302 clinical medicinePhysical medicine and rehabilitationAccelerometrymedicinerunningHumanslcsh:TP1-1185Electrical and Electronic EngineeringTreadmillGaitInstrumentationReliability (statistics)Impact accelerationspatio-temporalinstrumented treadmillRetrainingReproducibility of Resultsretraining030229 sport sciencesAtomic and Molecular Physics and Opticsimpact accelerationTransmission (telecommunications)Exercise TestRunning economySpatio-temporal030217 neurology & neurosurgerySensors
researchProduct

Optical quality of intraocular lenses after several years in the human eye

2013

The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…

medicine.medical_specialtyMaterials sciencegenetic structuresImage qualitybusiness.industrySpectral transmissionequipment and supplieseye diseasesAtomic and Molecular Physics and OpticsOptical qualityOpticsmedicine.anatomical_structureIntraocular lensesOphthalmologymedicineHuman eyesense organsbusinessJournal of Modern Optics
researchProduct

Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children

2018

Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL) thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL) and spherical equivalent (SE) in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls), ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children), myopia (100 children) and hyperopia (94 children) groups and according to axial AL in 68 short ([Formula: see text]22.00[Formula: see text]mm, 68), medium (from [For…

medicine.medical_specialtyRefractive errorgenetic structuresmagnification effectBiomedical EngineeringNerve fiber layerMedicine (miscellaneous)MagnificationEmmetropiaUlls -- Acomodació i refraccióSpherical equivalent:Ciències de la visió::Optometria::Acomodació i refracció [Àrees temàtiques de la UPC]lcsh:TechnologyEye--Accommodation and refractionLength measurement03 medical and health sciencesAxial length0302 clinical medicinechildrenOphthalmologyDegeneració retinalmedicinelcsh:QC350-467refractive errorRetinal degenerationOptical coherence tomographybusiness.industrylcsh:TMean ageAxial lengthmedicine.diseaseAtomic and Molecular Physics and Opticseye diseasesElectronic Optical and Magnetic Materialsmedicine.anatomical_structureCoherència (Òptica)OCT measurements030221 ophthalmology & optometryOptometrysense organsbusinessInfants030217 neurology & neurosurgerylcsh:Optics. LightOptic disc
researchProduct

High Dynamic Range Spectral Imaging Pipeline For Multispectral Filter Array Cameras

2017

Spectral filter arrays imaging exhibits a strong similarity with color filter arrays. This permits us to embed this technology in practical vision systems with little adaptation of the existing solutions. In this communication, we define an imaging pipeline that permits high dynamic range (HDR)-spectral imaging, which is extended from color filter arrays. We propose an implementation of this pipeline on a prototype sensor and evaluate the quality of our implementation results on real data with objective metrics and visual examples. We demonstrate that we reduce noise, and, in particular we solve the problem of noise generated by the lack of energy balance. Data are provided to the community…

medicine.medical_specialtySimilarity (geometry)Computer sciencePipeline (computing)Multispectral imageComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONspectral imaging02 engineering and technology[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processinglcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical Chemistry010309 optics[SPI]Engineering Sciences [physics]Color gel0103 physical sciences[ INFO.INFO-TI ] Computer Science [cs]/Image Processing0202 electrical engineering electronic engineering information engineeringmedicine[ SPI ] Engineering Sciences [physics]Computer visionlcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationHigh dynamic rangeComputingMilieux_MISCELLANEOUSbusiness.industryhigh dynamic rangespectral filter arraysAtomic and Molecular Physics and Opticsspectral imaging; spectral filter arrays; high dynamic range; image databaseSpectral imagingNoiseFilter (video)[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]020201 artificial intelligence & image processingArtificial intelligencebusiness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingimage database
researchProduct

2020

Gait variability observed in step duration is predictive of impending adverse health outcomes among apparently healthy older adults and could potentially be evaluated using wearable sensors (inertial measurement units, IMU). The purpose of the present study was to establish the reliability and concurrent validity of gait variability and complexity evaluated with a waist and an ankle-worn IMU. Seventeen women (age 74.8 (SD 44) years) and 10 men (73.7 (4.1) years) attended two laboratory measurement sessions a week apart. Their stride duration variability was concurrently evaluated based on a continuous 3 min walk using a force plate and a waist- and an ankle-worn IMU. Their gait complexity (…

medicine.medical_specialtyWaistCorrelation coefficient0206 medical engineeringConcurrent validitySTRIDE02 engineering and technologyAccelerometerBiochemistryAnalytical Chemistry03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationInertial measurement unitmedicineElectrical and Electronic EngineeringInstrumentationbusiness.industry020601 biomedical engineeringAtomic and Molecular Physics and OpticsSample entropymedicine.anatomical_structureAnklebusinesshuman activities030217 neurology & neurosurgerySensors
researchProduct

Effect of training level and blood flow restriction on thermal parameters: Preliminary study

2016

Abstract Training with blood flow restriction could lead to an effect on skin temperature. Additionally, this effect could be higher in people with lower physical fitness level due to their lower capacity of heat loss. The aim of this preliminary study was therefore to evaluate the effects of training experience on the acute and chronic thermal skin responses after performing exercise with and without blood flow restriction. The study included ten men, of these, five were trained. All subjects performed tests and re-tests for maximum strength (1 repetition maximum) through unilateral leg extensions (right thigh at 45 ± 6.7 kg and left thigh at 45.5 ± 8.1 kg, p > 0.05). The protocol consiste…

medicine.medical_specialtybusiness.industryStrength trainingTraining levelPhysical fitness030229 sport sciencesCondensed Matter PhysicsAtomic and Molecular Physics and OpticsConfidence intervalElectronic Optical and Magnetic MaterialsIntensity (physics)03 medical and health sciences0302 clinical medicineInternal medicineCardiologymedicinebusinessLead (electronics)Anterior compartment of thigh030217 neurology & neurosurgeryRight ThighInfrared Physics & Technology
researchProduct

Effects of a low-power He-Ne laser on the healing of experimental colon anastomoses: our experience

1992

Despite technical advances, the incidence of anastomotic leaks in elective colorectal surgery remains around 14%. Recent studies suggest that the use of low-energy lasers may enhance wound healing in different tissues in a selective, nondestructive manner. Based on these findings we have attempted to provide experimental background on the effects of a He-Ne laser during the early stages of healing in 155 colonic anastomoses performed on rats. The irradiation (external or endoscopical) ofthe anastomoses by repeated doses below 4 J/cm 2 suggest (1) the laser-induced enhancement of anastomotic healing can be obtained in both healthy colons or in situations in which anastomotic breakdown is mor…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industryGeneral EngineeringAnastomosisAtomic and Molecular Physics and OpticsColorectal surgerySurgeryEndoscopyColonic obstructionOpticsRepeated dosesAnastomotic leaksmedicineHe ne laserbusinessWound healingOptical Engineering
researchProduct

What influence patients'choice for peritoneal dialysis? a qualitative study

2018

L’objectif de cette étude était d’identifier les facteurs qui influencent le choix de la dialyse péritonéale (DP) chez les patients insuffisants rénaux, dans un centre de dialyse en France offrant un dispositif d’éducation thérapeutique du patient (ETP) aux patients en pré-dialyse. Pour ce faire, nous avons mené trente six entretiens semi-directifs avec des patients, des médecins de l’équipe d’ETP et un cadre de santé. Nous avons également observé dix séances d’ETP afin d’explorer la nature des interactions entre les patients, leurs accompagnants et l’équipe soignante. Nos résultats révèlent que les facteurs qui poussent les patients à choisir la DP sont l’influence des proches, les préfére…

medicine.medical_specialtymedicine.medical_treatment030232 urology & nephrologyDialysis patientsPeritoneal dialysis03 medical and health sciences0302 clinical medicineéducation thérapeutiquedialyse à domicileTherapeutic patient educationmedicineIn patient030212 general & internal medicineElectrical and Electronic EngineeringIntensive care medicineInternal medicineDialysisdialyse péritonéale[SHS.SOCIO]Humanities and Social Sciences/Sociologybusiness.industryrelation thérapeutiquemedicine.diseaseRC31-1245Atomic and Molecular Physics and Optics3. Good healthDialysis methodbusinesschoix thérapeutiquePatient educationKidney disease
researchProduct