Search results for " aorta"

showing 10 items of 185 documents

Aortic intramural hemorrhage visualized by transesophageal echocardiography: Findings and prognostic implication

1994

Abstract Objectives. This study describes the transesophageal echocardiographic and follow-up findings in patients with aortic intramural hemorrhage. Background. Localized aortic intramural hemorrhage resulting in layered thickening of the aortic wall seems to represent a variant of acute aortic dissection without communication or a typical moving intimal flap. In autopsy studies this variant, attributed to a rupture of the van vasorum, has been described in 5% to 10% of patients with dissection. Methods. In a prospective transesophageal echocardiographic study in patients with aortic dissection performed between 1986 and 1991, the diagnosis of intramural hemorrhage was established in 15 of…

Malemedicine.medical_specialtyTime FactorsAortic RuptureAorta ThoracicAutopsyDissection (medical)Asymptomaticmedicine.arteryAscending aortamedicineHumansProspective StudiesAortaAgedAortic dissectionAortaAortic Aneurysm ThoracicVascular diseasebusiness.industryPrognosismedicine.diseaseAortic AneurysmSurgeryAortic DissectionDescending aortacardiovascular systemFemaleRadiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealFollow-Up StudiesJournal of the American College of Cardiology
researchProduct

Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.

2013

To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …

Malemedicine.medical_specialtyTime FactorsAortic RuptureSubclavian ArteryAorta ThoracicDissection (medical)Kaplan-Meier EstimateProsthesis DesignThoracic aortic aneurysmAortographyAortic aneurysmBlood Vessel Prosthesis ImplantationAneurysmPostoperative ComplicationsBlood vessel prosthesismedicine.arterymedicineThoracic aortaHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesVascular PatencyAgedAged 80 and overAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic Dissectionsurgical procedures operativeTreatment OutcomeCardiothoracic surgerycardiovascular systemSurgeryFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Immunoglobulin G4-Related Aortitis and Severe Aortic Valve Stenosis Treated With Transcatheter Aortic Valve Replacement and Immunosuppression.

2021

Abstract IgG4-related disease is an immune-mediated fibro-inflammatory disorder with multisystemic involvement. Aortitis and peri-aortitis are the most common cardiovascular manifestations of the disease. We present the case of a 65-year-old man with symptomatic severe aortic stenosis and concomitant IgG4 aortitis. The diagnosis was confirmed by IgG4 serum levels, positive positron emission computed tomography (PET-CT) scans, and pathology from mediastinal dissection. Surgical aortic valve replacement (SAVR) was unfeasible owing to extensive mediastinal fibrosis, and transcatheter aortic valve replacement (TAVR) was successfully performed. As ascending aorta access for SAVR in IgG4 aortitis…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAorta ThoracicSeverity of Illness IndexTranscatheter Aortic Valve ReplacementMediastinal fibrosisAortic valve replacementValve replacementFibrosisInternal medicinemedicine.arteryPositron Emission Tomography Computed Tomographyparasitic diseasesAscending aortaMedicineHumansAortitisAgedAortitisbusiness.industryAortic Valve Stenosismedicine.diseaseStenosisAortic valve stenosisAortic ValveHeart Valve ProsthesisImmunoglobulin GCardiologyImmunoglobulin G4-Related Diseasemedicine.symptomCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesThe Canadian journal of cardiology
researchProduct

Cardiovascular dysfunction and vitamin D status in childhood acute lymphoblastic leukemia survivors

2018

Vitamin D (25-OHD) has a role in bone health after treatment for cancer. 25-OHD deficiency has been associated with risk factors for cardiovascular disease, but no data focusing on this topic in childhood cancer survivors have been published. We investigated the 25-OHD status in children treated for acute lymphoblastic leukemia (ALL), and evaluated its influence on vascular function. 25-OHD levels were evaluated in 52 ALL survivors and 40 matched healthy controls. Patients were grouped according to 25-OHD level (< 20 ng/m or ≥ 20 ng/ml). Auxological parameters, biochemical and hemostatic markers of endothelial function (AD, HMW-AD, ET-1, vWFAg, TAT, D-dimers, Fbg, and hs-CRP), ultrasound ma…

Malemedicine.medical_specialtyendocrine system diseasesAdolescentDiseaseAcute lymphoblastic leukemiaurologic and male genital diseasesGastroenterologyC-IMT03 medical and health sciencesYoung Adult0302 clinical medicineRisk Factors030225 pediatricsmedicine.arteryInternal medicinePediatric surgerymedicineVitamin D and neurologyHumans030212 general & internal medicineSurvivorsVitamin DChildChildhood Acute Lymphoblastic LeukemiaUnivariate analysisbusiness.industryAbdominal aortaConfoundingnutritional and metabolic diseasesCancerPrecursor Cell Lymphoblastic Leukemia-Lymphomamedicine.diseaseVitamin D DeficiencyCardiovascular diseaseChild PreschoolPediatrics Perinatology and Child HealthFemaleEndothelium VascularbusinessBiomarkersVascular ultrasound studie
researchProduct

Endograft repair of spontaneous infrarenal abdominal aortic dissection

2005

A 71-year-old man with a history of hypertension and a recent myocardial infarction experienced a sudden periumbilical and back pain. Abdominal tenderness was found at physical examination, with no changes in electrocardiogram and serial enzyme determinations. Computed tomographic angiography (CTA) showed a normal thoracic aorta, an infrarenal aortic dissection extending into the left common iliac artery and a contralateral iliac occlusive disease (A, Cover). Although antihypertensive therapy was administered, the patient had persistent pain; subsequently, he underwent endovascular repair with a bifurcated stent graft (Talent, Medtronic Ave, Santa Rosa, Calif) introduced via the left femora…

Malemedicine.medical_specialtymedicine.medical_treatmentDissection (medical)Settore MED/22 - Chirurgia VascolareAneurysm Dissectingmedicine.arteryMedicineThoracic aortaHumanscardiovascular diseasesAgedAortic dissectionbusiness.industryVascular diseaseAbdominal aortaStentendovascular repair aortic dissectionLeft Common Iliac Arterymedicine.diseaseAortic DissectionIntroducer sheathSurgeryRadiologybusinessCardiology and Cardiovascular MedicineVascular Surgical ProceduresHumanAortic Aneurysm AbdominalJournal of Vascular Surgery
researchProduct

Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis

2013

We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid-structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s(2)) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m(2)) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in t…

Malemedicine.medical_treatmentHemodynamicsAorta ThoracicMedicineThoracic aortaHematomamedicine.diagnostic_testEndovascular ProceduresModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeAnatomyTreatment OutcomeAtherosclerosiCardiologyWall shear streCardiology and Cardiovascular MedicineBrief CommunicationsBlood Flow VelocityHumanPulmonary and Respiratory Medicinemedicine.medical_specialtyAortographyAortic RuptureAortic DiseasesAortographyBlood Vessel Prosthesis ImplantationSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchinePenetrating atherosclerotic ulcerPenetrating atherosclerotic ulcerInternal medicinemedicine.arteryFluid-structure interactionShear stressHumansArterial PressureComputer SimulationHemodynamicAortic ruptureUlcerAgedEndovascular Procedurebusiness.industryHemodynamicsStentmedicine.diseaseAtherosclerosisAortic DiseaseBlood pressureRegional Blood FlowSurgeryStress MechanicalbusinessTomography X-Ray Computed
researchProduct

A mechanistic model on the role of “radially-running” collagen fibers on dissection properties of human ascending thoracic aorta.

2014

Aortic dissection (AoD) is a common condition that often leads to life-threatening cardiovascular emergency. From a biomechanics viewpoint, AoD involves failure of load-bearing microstructural components of the aortic wall, mainly elastin and collagen fibers. Delamination strength of the aortic wall depends on the load-bearing capacity and local micro-architecture of these fibers, which may vary with age, disease and aortic location. Therefore, quantifying the role of fiber micro-architecture on the delamination strength of the aortic wall may lead to improved understanding of AoD. We present an experimentally-driven modeling paradigm towards this goal. Specifically, we utilize collagen fib…

Materials sciencePeel forceFibrillar Collagens0206 medical engineeringBiomedical EngineeringBiophysicsAorta Thoracic02 engineering and technologyDissection (medical)030204 cardiovascular system & hematologyFiber bridge failure modelArticleWeight-Bearing03 medical and health sciences0302 clinical medicinemedicine.arteryCollagen fibermedicineAnimalsHumansThoracic aortaOrthopedics and Sports MedicineFiberAortaAortic dissectionAortaAortic Aneurysm ThoracicbiologyDissectionRehabilitationDelaminationModels CardiovascularBiomechanicsAnatomymedicine.disease020601 biomedical engineeringBiomechanical PhenomenaElastinExtracellular MatrixAortic Dissectionbiology.proteinFemaleElastinBiomedical engineering
researchProduct

Investigation of the hemodynamic flow conditions and blood-induced stresses inside an abdominal aortic aneurysm by means of a SPH numerical model.

2019

The estimation of blood flow-induced loads occurring on the artery wall is affected by uncertainties hidden in the complex interaction of the pulsatile flow, the mechanical parameters of the artery, and the external support conditions. To circumvent these difficulties, a specific tool is developed by combining the aorta displacements measured by an electrocardiogram-gated-computed tomography angiography, with the blood velocity field computed by a smoothed particle hydrodynamics (SPH) numerical model. In the present work, the SPH model has been specifically adapted to the solution of the 3D Navier-Stokes equations inside a domain with boundaries of prescribed motion. Images of the abdominal…

Materials scienceTime FactorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBiomedical EngineeringPulsatile flowHemodynamicsSettore ICAR/01 - IdraulicaPhysics::Fluid DynamicsAneurysmDiastolemedicine.arterymedicineShear stressPressureHumansComputer SimulationMolecular BiologyAortamedicine.diagnostic_testCardiac cycleApplied MathematicsHemodynamicsModels CardiovascularMechanicsmedicine.diseaseAbdominal aortic aneurysmBiomechanical PhenomenaComputational Theory and MathematicsModeling and SimulationAngiographycardiovascular systemHydrodynamicsStress MechanicalInfrarenal abdominal aorta aneurysm shear stresses arterial wall SPH moving boundarySoftwareAlgorithmsBlood Flow VelocityAortic Aneurysm AbdominalInternational journal for numerical methods in biomedical engineeringREFERENCES
researchProduct

Correlations between transmural mechanical and morphological properties in porcine thoracic descending aorta.

2015

Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morphological properties of descending porcine aorta. Histology and multi-photon microscopy were used for describing the media layer micro-architecture in the circumferential-radial plane, and Fourier Transform infrared imaging spectroscopy was utilized for determining structural protein, and total protein content. The distributions of these quantified properties across the media thi…

MorphologyMorphology (linguistics)Materials scienceSwineBiomedical EngineeringAorta ThoracicMulti-photon microscopy030204 cardiovascular system & hematologyArticleNanoindentationBiomaterials03 medical and health sciencesFourier Transform infrared imaging spectroscopy0302 clinical medicineElastic Modulusmedicine.arteryMaterials TestingMicroscopymedicineAnimalsNanotechnologyThoracic aortaElastic modulusAortaMechanical Phenomena030304 developmental biologyElastic Modulu0303 health sciencesAortabiologyAnimalFiber orientationAnatomyBiomaterialElastinBiomechanical PhenomenaExtracellular MatrixLamella (surface anatomy)Mechanics of MaterialsDescending aortabiology.proteinCollagenElastinBiomedical engineeringJournal of the mechanical behavior of biomedical materials
researchProduct

64-MDCT ECG gating in the evaluation of pre and post-operative ascending aorta: what is essential to know and necessary to report?

2007

Multidetector CT ascending aortaSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct