Search results for " array"
showing 10 items of 895 documents
A simulation and experimental study of electrochemical pH control at gold interdigitated electrode arrays
2021
Abstract In electroanalysis, solution pH is a critical parameter that often needs to be tailored and controlled for the detection of particular analytes. This is most commonly performed by the addition of chemicals, such as strong acids or bases. Electrochemical in-situ pH control offers the possibility for the local adjustment of pH at the point of detection, without the need for additional reagents. Finite element analysis (FEA) simulations have been performed on interdigitated electrodes, to guide experimental design in relation to both electroanalysis and in-situ control of solution pH. No previous model exists that describes the generation of protons at an interdigitated electrode arra…
Biochips for cell biology by combined dip-pen nanolithography and DNA-directed protein immobilization.
2013
A general methodology for patterning of multiple protein ligands with lateral dimensions below those of single cells is described. It employs dip pen nanolithography (DPN) patterning of DNA oligonucleotides which are then used as capture strands for DNA-directed immobilization (DDI) of oligonucleotide-tagged proteins. This study reports the development and optimization of PEG-based liquid ink, used as carrier for the immobilization of alkylamino-labeled DNA oligomers on chemically activated glass surfaces. The resulting DNA arrays have typical spot sizes of 4-5 μm with a pitch of 12 μm micrometer. It is demonstrated that the arrays can be further functionalized with covalent DNA-streptavidi…
RGB imaging system for mapping and monitoring of hemoglobin distribution in skin
2011
A prototype R-G-B imaging system for mapping of skin hemoglobin distribution has been designed and tested. Device basically consists of a commercial RGB sensor (CMOS, max. frame rate 87 fps for VGA resolution), RGB LED ringlight illuminator and orthogonally orientated polarizers for reducing specular reflectance. The system was examined for monitoring of hemoglobin concentration changes during specific provocations - arterial/venous occlusions and heat test. Hemoglobin distribution maps of several skin malformations were obtained, as well.
Chirped fibre Bragg gratings for phased-array antennas
1997
A variable delay line for phased-array antennas based on a chirped fibre Bragg grating is demonstrated. The time delay of a microwave modulating signal is modified by scanning in wavelength a chirped grating. In this initial experiment, time delay variations up to 556 ps have been achieved using a grating of 0.4 nm bandwidth and 6 cm length and modulating in the frequency range 390 MHz-5.20 GHz.
Extended gate electrode arrays for extracellular signal recordings
2000
Abstract We have fabricated arrays of planar gold electrodes arranged in a matrix of 8×8 with active areas ranging from 6 to 30 μm in diameter. An electronic amplification circuitry based on commercial junction field-effect transistors was used where the gold sensor fields act as extended gate electrodes (EGE) of the transistors, which leads to a new approach for long-term extracellular recording systems in vitro. The high input resistance of the amplification circuitry allows the use of small planar bare gold electrodes without further modification which therefore extends the frequency range of the measuring set-up down to the DC-level. The performance of our recording system has been test…
Ultrasonic phased array inspection of wire plus arc additive manufacture samples using conventional and total focusing method imaging approaches
2019
In this study, three aluminium samples produced by wire + arc additive manufacture (WAAM) are inspected using ultrasonic phased array technology. Artificial defects are machined using a centre drill, ø 3 mm, and electrical discharge machining (EDM), ø 0.5-1 mm, in a cylindrical through-hole topology. The samples are first inspected using a single-element wheel probe mounted on a KUKA robot in order to investigate the feasibility of using a conventional ultrasonic transducer approach. Unfortunately, the wheel probe is found to be unsuitable for scanning the WAAM specimens and ultrasonic phased arrays are employed next. The set-up includes 5 MHz and 10 MHz arrays (128 elements) in direct cont…
Microwave phase shifter based on fibre Bragg grating
1998
A variable delay line is presented for phased array antennas based on a fibre Bragg grating which has a uniform period and operates at constant optical wavelength. The Bragg wavelength of a localised part of the fibre grating is modified by straining the fibre, the optical carrier is reflected by the strained part of the grating and the time delay of the microwave modulating signal is determined by the position where the strain has been applied. In this initial experiment time delay variations up to 330 ps in the frequency range 1 – 14 GHz have been achieved.
Time-resolved FDTD and experimental FTIR study of gold micropatch arrays for wavelength-selective mid-infrared optical coupling
2021
The work was partially supported by Sweden's innovation agency Vinnova (Large area CVD graphene-based sensors/IR-photodetectors 2020-00797) and EU CAMART2 project (European Union's Horizon 2020 Framework Programme H2020-WIDESPREAD-01-2016-2017-TeamingPhase2 under grant agreement No.739508). TY acknowledges European Regional Development Fund Project No. 1.1.1.2/VIAA/4/20/740.
Colloidal lithography and Metal-Organic Chemical Vapor Deposition process integration to fabricate ZnO nanohole arrays
2010
A complete set up of optimal process conditions for an effective colloidal lithography/catalyst assisted MOCVD process integration is presented. It mainly focuses on the determination of the deposition temperature threshold for ZnO Metal-Organic Chemical Vapour Deposition (MOCVD) as well as the concentration of metal-organic silver (Ag) catalyst. Indeed, the optimization of such process parameters allows to tailor the ZnO film morphology in order to make the colloidal lithography/catalyst assisted MOCVD approach a valuable bottom up method to fabricate bi-dimensional ordered ZnO nanohole arrays. (C) 2010 Elsevier B.V. All rights reserved.
First lamina hybridization of high performance CFRP with Kevlar fibers: Effect on impact behavior and nondestructive evaluation
2022
The impact behavior of a carbon-Kevlar hybrid composite, widely used in sport car manufacturing, was evaluated. To highlight the hybridization effect, comparative analyses were performed with the basic CFRP laminate having the same lay-up. Tensile, bending and low velocity impact tests, followed by nondestructive inspections, highlighted that Kevlar first lamina hybridization leads to an increment in specific impact strength, up to 55%. To assess the most reliable technique to detect the impact damage, nondestructive evaluation was performed by pulsed thermography, phased array ultrasonic technique, computed tomography and digital radiography. Phased array ultrasonic technique can be consid…