Search results for " array"

showing 10 items of 895 documents

High spin band structures in104Cd

1995

High spin states in Cd-104 have been investigated by means of heavy ion induced reactions using the Nordball detector array. The level scheme constructed from yy-coincidences is dominated by three ...

PhysicsNuclear and High Energy PhysicsSpin statesNuclear fusionHeavy ionDetector arrayAtomic physicsNuclear ExperimentZeitschrift f�r Physik A Hadrons and Nuclei
researchProduct

High resolution Time of Flight determination based on reconfigurable logic devices for future PET/MR systems

2013

Abstract This contribution shows how to perform Time of Flight (TOF) measurements in PET systems using low-cost Field Programmable Gate Array (FPGA) devices with a resolution better of 100 ps. This is achieved with a proper management of the FPGA internal resources and with an extremely careful device calibration process including both temperature and voltage compensation. Preliminary results are reported.

PhysicsNuclear and High Energy PhysicsTime of flightVoltage compensationbusiness.industryProcess (computing)CalibrationHigh resolutionbusinessField-programmable gate arrayInstrumentationComputer hardwareNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Investigation of the (d, p)-reaction on136, 132Xe in inverse kinematics

1991

The one-neutron transfer reactions d(132,136 Xe, p)133,137 Xe have been investigated in inverse kinematics with xenon beams incident on deuterium loaded titanium targets. The angular distributions of the protons, measured with a detector array of 100 PIN-photodiodes, have been analyzed using standard DWBA. Generally, good agreement is obtained with results previously obtained in reactions induced by light-ion beams.

PhysicsNuclear and High Energy PhysicsXenonDeuteriumchemistryInverse kinematicschemistry.chemical_elementNuclear fusionAtomic physicsDetector arrayNuclear ExperimentTitaniumZeitschrift f�r Physik A Hadrons and Nuclei
researchProduct

Time of flight measurements based on FPGA and SiPMs for PET–MR

2014

Coincidence time measurements with SiPMs have shown to be suitable for PET/MR systems. The present study is based on 3 x 3 mm(2) SiPMs, LSO crystals and a conditioning signal electronic circuit. A Constant Fraction Discriminator (CFD) is used to digitalize the signals and a TDC FPGA-implemented is employed for fine time measurements. TDC capability allows processing the arrival of multiple events simultaneously, measuring times under 100 ps. The complete set-up for time measurements results on a resolution of 892 +/- 41 ps for a pair of detectors. The details of such implementation are exposed and the trade-offs of each configuration are discussed. (C) 2013 Elsevier By, All rights reserved,

PhysicsNuclear and High Energy Physicsbusiness.industryDetectorSilicon photomultipliersConstant fraction discriminatorPositron emission tomography and magnetic resonanceSignalTime-to-digital converterTime of flightTime of flightOpticsSilicon photomultiplierField Programable Gate ArrayTime-to-digital converterbusinessField-programmable gate arrayInstrumentationElectronic circuitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Shape coexistence in 117I

1992

The 117I nucleus has been investigated in a high-spin gamma-spectroscopic study using the NORDBALL detector array. The observed level structures are interpreted as resulting from coexisting collect ...

PhysicsNuclear physicsNuclear and High Energy Physicsmedicine.anatomical_structure010308 nuclear & particles physics0103 physical sciencesmedicineNuclear fusionDetector array010306 general physics01 natural sciencesNucleusZeitschrift für Physik A Hadrons and nuclei
researchProduct

In-beam study of 102In, 104In and 106In

1995

Proton-rich odd-odd In isotopes have been investigated by in-beam spectroscopic methods using the NORDBALL detector array. A Ni-58 beam with an energy of 270 MeV was used to bombard a Fe-54 target. ...

PhysicsNuclear physicsNuclear reactionNuclear and High Energy PhysicsIsotopeNuclear TheoryPhysics::Accelerator PhysicsAtomic physicsDetector arrayNuclear ExperimentBeam (structure)Energy (signal processing)Nuclear Physics A
researchProduct

Maximally aligned states in the proton drip line nucleus 106Sb

2005

High-spin states in Sb-106 have been investigated in the Fe-54(Ni-58, 1α 1p1n) reaction by in-beam γ-spectroscopic methods using the EUROBALL detector array equipped with charged particle and neutr ...

PhysicsNuclear reactionNuclear and High Energy PhysicsProton010308 nuclear & particles physics01 natural sciencesCharged particle3. Good healthGamma gammamedicine.anatomical_structure0103 physical sciencesmedicineAtomic physicsDetector array010306 general physicsNucleusLine (formation)
researchProduct

FARCOS, a new array for femtoscopy and correlation spectroscopy

2012

Correlations between two or more particles can be used as a tool to explore the space-time features of nuclear reactions as well as spectroscopic properties of produced unbound clusters. In order to have new options to study the mentioned correlations, FARCOS (Femtoscope ARray for COrrelations and Spectroscopy) has been conceived as a compact high resolution array, composed of square telescopes. In this work the main features of FARCOS array as well as part of the physics cases are described. © Owned by the authors, 2012.

PhysicsNuclear reactionsezeleFemto- scope ARray for COrrelations and SpectroscopyPhysicsQC1-999High resolutionEngineering physicsSquare (algebra)Computational physicsPhysics and Astronomy (all)SpectroscopyTwo-dimensional nuclear magnetic resonance spectroscopy
researchProduct

Upgrade of the ATLAS Level-1 trigger with an FPGA based Topological Processor

2013

The ATLAS experiment is located at the European Centre for Nuclear Research (CERN) in Switzerland. It is designed to measure decay properties of high energetic particles produced in the protons collisions at the Large Hadron Collider (LHC). The LHC has a proton collision at a frequency of 40 MHz, and thus requires a trigger system to efficiently select events down to a manageable event storage rate of about 400Hz. Event triggering is therefore one of the extraordinary challenges faced by the ATLAS detector. The Level-1 Trigger is the first rate-reducing step in the ATLAS Trigger, with an output rate of 75kHz and decision latency of less than 2.5$\mu$s. It is primarily composed of the Calori…

PhysicsParticle physicsLarge Hadron ColliderPhysics::Instrumentation and DetectorsNuclear TheoryATLAS experimentUpgrademedicine.anatomical_structureAtlas (anatomy)Optical receiversmedicinePhysics::Accelerator PhysicsSignal processing algorithmsHigh Energy Physics::ExperimentDetectors and Experimental TechniquesNuclear ExperimentField-programmable gate array
researchProduct

Coexistence of collective and quasiparticle structures in 106, 108Sn nuclei

1995

New revels in two neutron deficient nuclei Sn-106.108 have been found by using the Nordball detector array extended with the arrangements of charged particle and neutron detectors. The excited stru ...

PhysicsPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaNuclear TheoryCondensed Matter PhysicsAtomic and Molecular Physics and OpticsCharged particleNuclear physicsExcited stateNeutron detectionParticleHigh Energy Physics::ExperimentNeutronDetector arrayAtomic physicsNuclear ExperimentMathematical PhysicsPhysica Scripta
researchProduct